background image

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

888-994-7636,  fax 888-864-7636

unifiedbrands.net

PART NUMBER PP MNL1705, REV. D (08/23)

This manual provides information for:

65348-290 SELF-CONTAINED 
WORK-TOP FREEZER

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.  READ, 
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED 
IN THIS MANUAL.

FOR YOUR SAFETY

 Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

WARNING

 

R290 flammable refrigerant in use. 

Improper installation, 

adjustment, alteration, service or maintenance can cause property damage, 
injury or death.  Read the installation, operating and maintenance instructions 
thoroughly before installing or servicing this equipment.

NOTIFY CARRIER OF DAMAGE AT ONCE

 It is the responsibility of the 

consignee to inspect the container upon receipt of same and to determine 
the possibility of any damage, including concealed damage. Randell suggests 
that if you are suspicious of damage to make a notation on the delivery 
receipt. It will be the responsibility of the consignee to file a claim with the 
carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

 

NOTICE: Due to a continuous program of product improvement, Randell  reserves the 
right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation.  If certain 
recommended procedures are not followed, warranty claims will be denied.

MODEL NUMBER _________________________

SERIAL NUMBER _________________________

INSTALLATION DATE ______________________
The serial number is located in the cabinet left side 
under the drawer track.  An example is shown here. 

EQUIPMENT DESCRIPTION

MODEL

LENGTH

DEPTH

HEIGHT

NO. OF 

DOORS

STORAGE

(CUBIC FEET)

 POWER USAGE

 

(KW PER DAY)

COMPRESSOR

VOLT

AMPS

NEMA

SHIP WT 

(LBS)

65348-290

48"

33"

36"

2

12.89

4.02

 1/2

115/60/1

6.0

5-15P

250*

INSTALLATION

CAUTION:  THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT.  USE CAUTION WHEN 

HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER.  AVOID 

DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A LEAK. 

WARNING:  FAILURE TO FOLLOW INSTALLATION GUIDELINES AND 

RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.

WARNING:  IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE. 

CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE 

FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON 

THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING 

VOLTAGE LIMITS WILL VOID THE WARRANTY.

 

THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT 
OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V.

WARNING:  THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL, 

INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE 

SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15. 

SELECTING A LOCATION FOR YOUR NEW UNIT

The following conditions should be considered when selecting a location for your 
unit:
1.  Floor & Countertop Load:  The area on which the unit will rest must be level, 

free of vibration, and suitably strong enough to support the combined weights 
of the unit plus the maximum product load weight.  NOTE:  If there is a question 
pertaining to weight load limits, consult the factory at 1-888-994-7636.

2.  Clearance:  Clearance must be a combined total of at least 1” on back of 

unit. Do not place any object that can block the ventilation exhaust from 
the machine compartment register. Area of equipment must be free of all 
combustible materials. 

3.  Ventilation:  The air cooled self contained unit requires a sufficient amount 

of cool clean air.  Avoid surrounding your unit around other heat generating 
equipment and out of direct sunlight.  Also, avoid locating in an unheated room 
or where the room temperature may drop below 70°F (21°C) or rise above 
86°F (32°C).

Information contained in this document is known to be current and accurate at the time of printing/creation. Reference our product line website for the most updated 

product information and specifications. © 2023 Electrolux Professional, Inc. All Rights Reserved. 

Summary of Contents for 65348-290

Page 1: ...0 1 6 0 5 15P 250 INSTALLATION CAUTION THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT USE CAUTION WHEN HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER AVOID DAMAGING THE REFRIGERANT TUBING OR IN...

Page 2: ...ES TO DEFROST REFRIGERATOR DO NOT PUNCTURE REFRIGERANT TUBING RIESGO DE INCENDIO O EXPLOSI N REFRIGERANTE INFLAMABLE UTILIZADO NO UTILICE DISPOSITIVOS MEC NICOS PARA DESCONGELAR EL REFRIGERADOR NO PER...

Page 3: ...tion of warm water and a mild detergent to extend gasket life 3 Lubricate door hinges with lithium grease RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING JOB CLEANING AGENT COMMENT...

Page 4: ...NG ANY REPAIRS ENSURE THE UNIT IS DISCONNECTED FROM ITS POWER SOURCE This piece of equipment uses a R290 Refrigeration system This equipment has been clearly marked on the serial tag the type of refri...

Page 5: ...COIL MOUNT RC300 6 PB ELB504 ELBOW 3 8 90 CU C X C 7 RF COI9905 COIL 4 X 7 5 X 21 8 RF FAN1401 FAN AXIAL EVAPORATOR 119MM X 38MM 115V 9 RF FAN0703 FAN GUARD NICKEL CHROME FINISH WIRE 116MM RND 10 EL...

Page 6: ...1704 SUPPORT RIGHT SHELF 65348 T07 1136 4 RP SPC1701 SPACER PANEL FRONT MULLION 5 HD CST1301 CASTER LOCKING HEIGHT ADJUSTABLE 6 000 TO 6 812 5A HD CST1207 CASTER HEIGHT ADJUSTABLE 6 000 TO 6 812 PNFG3...

Page 7: ...3 46 X 9 00 X 5 90 CONDENSER 4 RF FLT9902 DRYER 1 4x 042 FILTER EKP 032 SC DBL INL CAP TUBE N 5 RP SHD1702 SHROUD FAN 65348 65360 PANDA 6 RP CPN1701 DRAIN PAN COMPRESSOR PANDA 7 RF FAN1401 FAN AXIAL...

Page 8: ...R HINGE 4 HD HDL0103 HANDLE BLACK 5 4x1 4 HD HDL251 5 RP HNG023 HINGE TOP L BRACKET W O COLLAR 6 RP HNG035 HINGE TOP DOOR CHANNEL RIGHT HAND 7 RP HNG034 HINGE TOP DOOR CHANNEL LEFT HAND 8 RP HNG9901 H...

Page 9: ...9 OM 65348 290 SELF CONTAINED WORK TOP FREEZER Electrical Schematic...

Page 10: ...M 65348 290 SELF CONTAINED WORK TOP FREEZER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed...

Page 11: ...RANGEMENT PIED CUBE CONSOMMATION LECTRIQUE KW PAR JOUR COMPRESSEUR VOLTS AMPS NEMA POIDS L EXP DITION LB 65348 290 122 cm 48 po 84 cm 33 po 91 44 cm 36 po 2 12 89 4 02 1 2 115 60 1 6 0 5 15P 250 Poid...

Page 12: ...IER INT RIEUR DU PANNEAU DE L VAPORATEUR EXT RIEUR DE L APPAREIL RISK OF FIRE OR EXPLOSION FLAMMABLE REFRIGERANT USED DO NOT USE MECHANICAL DEVICES TO DEFROST REFRIGERATOR DO NOT PUNCTURE REFRIGERANT...

Page 13: ...s de pr f rences avec une solution d eau ti de et d un d tergent doux pour prolonger la vis des joints 3 Lubrifier les charni res de porte avec de la graisse au lithium LES PRODUITS NETTOYANTS SUIVANT...

Page 14: ...IT S SONT DISONNECTED DE SES SOURCES D NERGIE Cet appareil utilise un syst me de r frig ration R290 Le type de r frig rant utilis est clairement indiqu sur l tiquette du num ro de s rie de l appareil...

Page 15: ...ELB504 COUDE 0 95 CM 3 8 PO 90 CU C X C 7 RF COI9905 SERPENTIN 10 X 19 X 53 34 CM 4 X 7 5 X 21 PO 8 RF FAN1401 VENTILATEUR AXIAL DE L VAPORATEUR 119MM X 38MM 115V 9 RF FAN0703 GRILLE DE PROTECTION FI...

Page 16: ...36 4 RP SPC1701 PANNEAU ENTRETOISE MONTANT INTERM DIAIRE AVANT 5 HD CST1301 ROULETTE VERROUILLABLE HAUTEUR R GLABLE 15 24 CM 6 000 PO 17 3 CM 6 812 PO 5A HD CST1207 ROULETTE HAUTEUR R GLABLE 15 24 CM...

Page 17: ...902 FILTRE DE S CHOIR 1 4 X 0 042 EKP 032 SC AVEC TUYAU DOUBLE OU ES 5 RP SHD1702 COUVERCLE DU VENTILATEUR 65348 65360 PANDA 6 RP CPN1701 BAC DE VIDANGE DU COMPRESSEUR PANDA 7 RF FAN1401 VENTILATEUR A...

Page 18: ...G023 SUPPORT SUP RIEUR EN L DE LA CHARNI RE SANS COLLIER 6 RP HNG035 SUPPORT DE CHARNI RE SUP RIEUR PORTE DROITE 7 RP HNG034 SUPPORT DE CHARNI RE SUP RIEUR PORTE GAUCHE 8 RP HNG9901 CHARNI RE FERMETUR...

Page 19: ...ONDENSEUR VENTILATEUR 1 VENTILATEUR 2 VENTILATEUR DE L VAP 1 BLEU BLANC BLEU BLANC VENTILATEUR DE L VAP 2 LIMITE DE D GIFRAGE L MENT CHAUFFANT DE D GIVRAGE 115V CHAUFFERETTE AVANT 1 CHAUFFERETTE AVANT...

Page 20: ...G LATEUR AVEC SURFACE DE TRAVAIL AUTONOME Journal d entretien N de mod le Achet de N de s rie Emplacement Date d achat Date d installation N du bon de commande Pour un appel de service Date Entretien...

Reviews: