background image

ELECTRONIC PANEL  LRX 2035 ALARM 

 
Control panel that integrates electronic control for single-phase 
motor 230 Vac and Alarm System for the supervision of 2 wired 
zones. 
The  control  panel,  equipped  with  intergrated  battery  charger 
and radio receiver, is ideal for automation and safety of garage 
doors, over head doors and rolling shutters. 
The  control  panel  can  be  used  in  a  combine  manner,  so  that 
the management of automation and alarm system is reported to 
a single command, or so that a separate control for automation 
alone and a control for the alarm system alone. 
 
- Mod.   LRS 2035 Alarm               : 433,92 Mhz 
- Mod.   LRS 2035 SET Alarm       : 433,92 Mhz  “narrow band” 
- Mod.   LRH 2035 Alarm              : 868,3   Mhz  “narrow band” 
 

 
IMPORTANT FOR THE USER 

-The  device  can  be  used  by  up  to  8-year-old  children  or 
persons    with  reduced  physical-psychological  abilities  or 
with  little  knowledge  and  experience,  only  if  they  are 
supervised  or  trained  on  the  functioning  and  the  use 
modalities in a safe way, to better know also the dangers 
during its use. 
- This instructions are available also on the website  

www.seav.com

-  Do  not  allow  children  to  play  with  the  device  and  keep 
the radio-controls away from their reach.  
 Frequently examine the plant to detect any signs of  
damaging. Do not use the device if a repair intervention is 
necessary.  
-Always  remember  toremove  the  power  source  before 
polish or maintenace works. 
-Polish  and  maintenance  works  must  not  be  done  by 
children without any supervision.

 

 

ATTENTION:  keep  this  instruction  manual  and  respect 
the important safety prescriptions contained herein.  
The  not  compliance  with  the  prescriptions  may  cause 
damages and serious accidents. 

 
 

 
IMPORTANT FOR THE INSTALLER 
 

1)Before automating the frame, check that it is in good 
conditions, in compliance with the Machinery Directive 
and with EN 12604.

 

2) Control that place, where the installation is situated, 
respects the Temperature working limits, fixed for the 
device.

 

3) The safety for the final installation and the respect of all 
the rules (EN 12453 – EN 12445) are under responsability 
of the person, who Assembly all the parts together for 
building a closing.

 

4) Use safety disposals which can control their connection 
to the Electric panel.

 

5)To be sure of having done a right installation, you 
should do a coplete check-up (progra-mation of the 
electric unit and correct installation of safety disposals).

 

6)  In  the  back  side,  the  shell  is  equipped  with  wall 
fastening set up (holes for fastening by dowels or screws). 
Consider  and  implement  all  Efforts  for  an  installation  that 
does not change the IP degree. 

7)  The  control  unit  does  not  have  any  type  of  isolating 
device    for  the  230  Vac  line.  It  will  therefore  be  the 
responsibility of the installer to Arrange an isolating device 
inside  the  plant.  It  is  necessary  to  install  A  monophase 
switch with over-voltage category III. It must be Positioned 
where  it  can  protected from accidental closing, according 
To that prescribed in point 5.2.9. of EN 12453.   
8) For what concerning cables for power, you should use 
flexible  Cables  under  policloroprene  insulating  sheath  of 
harmonized  type  (H05RN-F)  with  1mm²  minimum  size  of 
conductor wires. 
9)  The  gearmotor  used  to  move  the  frame  must  comply 
with that prescribed at point 5.2.7 of EN 12453.  
10)  In  compliance  with  5.4.2  of  EN  12453,  it  is 
recommended  to  use  gearmotors  equipped  with  an 
electric-mechanical  release  device,  so  that  the  door  can 
be moved manually in case of necessity.   
11) In compliance with 5.4.3 of EN 12453, use electric- 
mechanical release systems or similar devices which stop 
the door safely in the end run position.  
12) Wiring of the various electrical components outside of 
the control unit must be carried out in compliance with that 
prescribed  in  Standard  EN  60204-1  and  its  amendments 
at point 5.2.7 of EN 12453. Cables for power can have a 
14  mm  Maximum  diameter  size.    Power  supply  and 
connection cables must be fixed using the cable “optional” 
provided. Please Be aware of fixing the cables in order to 
attach  them  in  a  solid  Way.  Moreover,  during  the  shell 
drilling  phase  to  let  the  power  and  connection  cables  go 
through, and the cable glands assembly, warning to Install 
everything  in  order  to  maintain  unchanged  the  IP-degree 
properties of the box. 
13)  Mounting  of  a  push  button  panel  for  manual  control 
must be done positioning the push button panel where the 
user is not in a dangerous position. 
14)  The  plastic  box  is  lacking  in  anti-intrusion  Tampere 
connection  In  the  removable  part  of  the  Switch,  so  it  is 
recommended  the  Assembly  by  the  installer  for  a  major 
safety to the Alarm system. 
15) The safety function, guaranteed by the electronic unit, 
operates  Only  during  the  closure;  so  the  opening 
protection  must  be  Guaranteed  by  independent  actions 
(havens or safety distance) From the control circuit during 
the installation. 
16) For a correct functioning of the radio receiver, if using 
one  or  More  control  units,  the  installation  at  a  minimum 
distance  of  at  least  3  metres  one  from  the  other  is 
recommended. 

 
 

 

 

Electronic control unit: 

 

LRS 2035 Alarm 

LRS 2035 SET Alarm – LRH 2035 Alarm 

 

Comply with the specifications of the Directives 

R&TTE 99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC. 

 

 

GB 

Reviews: