AB-Z  # 21 015

Translation of the original operation manual GB, Stand 06 / 2018

i

Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor. - Technical Modifications are subject to change. - Details techniques subject à modification sans avis préalable

O P T I M I Z E S     W O R K   R O U T I N E S     E N V I R O N M E N T A L L Y     E F F E C T I V E     S E C U R E

Summary of Contents for AB-Z

Page 1: ...i Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor Technical Modifications are subject to change Details techniques subject modification sans avis pr alable O P T I M I Z E S W O R K...

Page 2: ...moved Always wear safety cloths respecting the applicable regulations for accident prevention Only use this device conforming to its purpose and function Improper use can cause severe injuries Caution...

Page 3: ...meter features two numerical registers and various indications displayed to the user only when the applicable function so requires KEY 1 Partial register 5 figures with moving comma from 0 1 to 99999...

Page 4: ...er protection 1 9 Bearing 2 3 Self tap screw ST 2 9x9 5 2 10 Self tap screw ST 2 9x13 4 4 Battery holder 1 11 Turbine 1 5 Electro board 1 12 Bearing holder 1 6 Battery CR2 1 13 Self tap screw ST 2 9x6...

Page 5: ...mode 7 3 Usage Button usage calibration and measurement unit change Reset the present total Fig 2 7 3 1 When the meter is on standby press the RESET key 7 3 2 The display shows all the segments 7 3 3...

Page 6: ...FLOW RATE L RESET TOTAL L FLOW RATE L GAL PT QT RESET TOTAL FLOW RATE Fig 4 Fig 5 7 4 Reset the resettable total Fig 5 When the meter is on standby press RESET key for two seconds to reset the present...

Page 7: ...T TOTAL Abb 5 7 5Procedure for enter the correction factor directly Carefully follow the procedure indicated below Formula Example Actuyl value 20 75 Display value 18 96 Current corection factror 1000...

Page 8: ...oose the right digit from 0 to 9 Press the MENU key to start the next digit So the digit of correction factor can be changed one by one 7 5 5 Make sure the correction factor is righ press the MENU key...

Page 9: ...displayed on the LCD is the display value not the actual value which may be slightly higher For example in the display on the right the display value is 18 96 while the actual value is 20 75 7 6 4 Pre...

Page 10: ...factor is right and then press the MENU key Keep it pressed until calibration is finished and the factor is save The meter will then return to standby 8 Maintanace and trouble shooting 8 1 Battery rep...

Page 11: ...11 49 6158 92980 0...

Page 12: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 12 49 6158 92980 0...