It is the law that all gas appliances are installed by a 

competent person, in accordance with the gas safety 

installation and use current regulations. 

To the current Gas Safety (Installation and Use) 

Regulations B.S. 5440:2 - (2000).

All CORGI registered installers carry a CORGI I.D. card 

and have a registration number. Both should be recorded 

in your boiler log book. You can check your installer by 

calling CORGI direct on: 01256 732300.

PLEASE NOTE

Due  to  the  high  efficiency  and  resulting  low  flue  gas 

exhaust  temperature  a  white  plume  of  condensation  

vapour  (cool  steam)  will  be  emitted  from  the  flue  outlet  

terminal, this is quite normal. It will be particularly evident 

during periods of low outdoor temperatures or when the 

boiler is working at its optimum performance.

1.2.1 

Minimum clearances are required for safety and 

maintenance. 

 

Do  not  obstruct  any  purpose  made  ventilation 

opening if boiler has been fitted in a compartment. 

Never  hang  clothes,  etc.,  over  the  appliance.

1.3

 

USER CONTROLS 

See Fig. 1

1.3.1   This  appliance  is  designed  to  operate  with  the 

minimum of attention by the user. 

 

All controls are to be found on the control panel.

1.4

 

OPERATING SAFETY CHECKS TO 

 

PROTECT YOUR APPLIANCE

1.4.1 

Before  lighting  the  appliance  check  central  

heating  system  pressure  (7)  is  not  less  than 

1 bar gauge.  If it is below  this do  not light  but  

consult your installer about refilling your system 

as you may have a leak in the system.

1.4.2 

A  RED  warning  light  on  the  control  panel  (8)  

warns of a flame failure of the burner. This can 

be reset manually by pressing mains boiler on/

off switch (1).

1.4.3   A RED warning intermittence light on the control 

panel (8) warns of a high temperature lockout on 

the overheat thermostat. This could occur due to 

air or poor circulation in the boiler/heating circuit. 

This can be reset manually by pressing mains 

boiler on/off switch (1). If lockout should persist 

leave the appliance shut down and consult your  

installer/service engineer immediately.

1.4.4   The CSI 85 condensing boiler is fitted with a con-

densate outlet which must be connected by the 

installer to a suitable discharge point as speci-

fied in the installation manual. 

 

On  no  account  should  this  discharge  pipe  be  

blocked or modified.

Escape of gas

 

Should a gas leak be suspected, contact your gas supplier 

without delay.

Do NOT search for gas leaks with a naked flame. 

WARNING:

 This appliance must be earthed.

Do  not  touch  or  tamper  with  this  sealed  unit  or  its 

components.

1. 

INTRODUCTION

1.1 

Please  carefully  read  information  given  in  the  

booklet  to  help  you  gain  maximum  control  from 

your appliance with minimum trouble and cost.

1.1.1  Your  Ravenheat  Condensing  Combination  Boiler 

has been designed to supply your Central Heating 

and  Domestic  Hot  Water  directly  from  one  unit. 

When central Heating is operating, the circulation 

will be interrupted when domestic hot water is being 

drawn off. This will normally not affect the level of 

heating.

CLEARANCES AROUND THE BOILER

Above 125mm (5 inches)

Below 150mm (6 inches) 

Front 450mm (18 inches) 

Sides 5mm (0.2 inches)

25mm (1 inch) in front when installed in a cupboard.

CONDENSING SYSTEM INNOVATION SUPER HIGH EFFICIENT AUTOMATIC MODULATING

COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER

USER’S GUIDE 

CSI 85 B (T) - CSI 85 A (T) 

WITH OR WITHOUT BUILT IN TIMER