background image

USER’S GUIDE

HIGH EFFICIENT COMBINATION BOILER

RSF 84ET - RSF 84E - RSF 100ET - RSF 100E

WITH OR WITHOUT BUILT IN TIMER

It is the law that all gas appliances are installed by

a competent person, in accordance with the gas
safety installation and use current regulations.
To the current Gas Safety (Installation and Use)

Regulations “1996”

All CORGI registered installers carry a CORGI I.D.

card and have a registration number. Both should be
recorded in your boiler log book. You can check your
installer by calling CORGI direct on: 01256 732300.

Escape of gas

Should a gas leak be suspected, contact your gas

supplier without delay.

Do NOT search for gas leaks with a naked flame.

WARNING:

This appliance must be earthed.

Do not touch or tamper with this sealed unit or
its components

1.

1.1

INTRODUCTION

Please carefully read information given in

the booklet to help you gain maximum con-

trol from your appliance with minimum
trouble and cost.

1.1.1

Your Ravenheat Combination Boiler has
been designed to supply your Central

Heating and Domestic Hot Water directly

from one unit.
When central Heating is operating, the cir-
culation will be interrupted when domestic
hot water is being drawn off. This will nor-
mally not affect the level of heating.

1.2.1

1.4.2

1.4.3

CLEARANCES AROUNDTHE BOILER

RSF 84E(T)

RSF 100E(T)

Above

125 mm

150 mm

Below

100 mm

100 mm

Front

450 mm

450 mm

Sides

75 mm

5 m m

25mm in front when installed in a cupboard.

Minimum clearances are required for safety
and maintenance. Do not obstruct any pur-
pose made ventilation opening if boiler has
been fitted in a compartment.
Never hang clothes, etc., over the appliance.

USER CONTROLS

See Fig. 1

This appliance is designed to operate with the

minimum of attention by the user. All controls

are to be found on the control panel.

OPERATING SAFETY CHECKS TO

PROTECTYOUR APPLIANCE

Before lighting the appliance check central

heating system pressure (7) is not less than 1

bar gauge. If it is below this do not light but

consult your installer about refilling your sys-
tem as you may have a leak in the system.

An ORANGE warning light on the control pan-
el (8) warns of a flame failure of the main
burner. This can be reset manually by press-
ing mains boiler on/off switch (1).

A RED warning light on the control panel (9)
warns of a high temperature lockout on the
overheat thermostat. This could occur due to air

or poor circulation in the boiler/heating circuit,

This can be reset manually by removing grey
cover (3) on control panel and pressing red re-
set button. Replace cap. If lockout should per-

sist leave the appliance shut down and consult

your installer/service engineer immediately.

Reviews: