background image

WARNING 
This information is a copy of an original 
archive, therefore Aga cannot be held 
responsible for its continued accuracy.

 

Summary of Contents for Regent

Page 1: ...WARNING This information is a copy of an original archive therefore Aga cannot be held responsible for its continued accuracy ...

Page 2: ......

Page 3: ......

Page 4: ...en handling use disposable gloves Fire cement when handling use disposable gloves Glues and sealants exercise caution if these are still in liquid form use face mask and disposable gloves Glass Yarn Mineral Wool Insulation Pads Ceramic Fibre may be harmful if inhaled may be irritating to skin eyes nose and throat When handling avoid inhaling and contact with skin or eyes Use disposable gloves face...

Page 5: ...should be made good with the fire cement provided Replace hot plate making sure that it is seating properly on the asbestos rope It should be approximately Xe proud of the enamelled hob with an equal space all round When lighting the fire for the first time allow the cooker to heat up gradually FIREBRICK REPLACEMENT The firebricks fitted to Rayburn Cookers are of first quality manufacture and prov...

Page 6: ...tly at this level but if the fire is allowed to bum very low there will be a time lag after refuelling before the heat reaches the oven hotplate and boiler When burning coal or anthracite time should be allowed for a fresh charge to ignite before the damper is closed open the chimney damper fire door and ashpit door Kindle with paper and sticks in the ordinary way Leave the doors open until the fi...

Page 7: ...hould prove successful in almost all cases but if closing the chimney damper causes the fire to smoke it should be opened gradually till the smoking stops To reduce top heat in the oven place the sheet metal shelf on the top pair of runners The oven may be cleaned with a stiff wire brush waken it is very hotb OVEN TEbTPEJLATURES Hot 400 500 Moderate 300 4060 Slow 200 300 THE HOTPLATE The best resu...

Page 8: ...tructions for Heating Engineers Turn dff the water from the main and drain the system Disconnect flow and return pipes and withdraw boiler through side of the cooker inspection panel and take out the insulating material on top and behind boiler After replacing boiler repack the insulating material above and behind the boiler Make good with fire cement the joints between boiler and fire bricks Re m...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Reviews: