P/N 241758 Rev 4

4000856

 

Tested to UL Standard 1261

CATALOG NO. 6100.63C

Effective: 05-01-19

Replaces: 03-01-19

INSTALLATION AND OPERATION 

MANUAL

Electric Heater

MODELS

ELS 0005, ELS 0011, 

ELS 0018, and ELS 0027

 

FOR YOUR SAFETY:

 Do not store or use gasoline or other flammable vapors and 

liquids or other combustible materials in the vicinity of this or any other appliance. 

 

To do so may result in an explosion or fire.

NOTE:

 The instructions in this manual are for the use of qualified individuals specially trained and experienced 

in the installation and maintenance of this type of equipment and related system components. Installation and 

service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install, 

service, or maintain this equipment.

This manual should be maintained in legible condition and kept adjacent to the electric heater or in a safe place 

for future use.

Summary of Contents for ELS 0005

Page 1: ...er appliance To do so may result in an explosion or fire NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and mainten...

Page 2: ...immediate hazards which will cause severe personal injury death or substantial property damage if ignored WARNING Indicates the presence of hazards or unsafe practices which could cause severe person...

Page 3: ...EW Congratulations on the purchase of the most advanced spa pool electrical heater in the market To get the best performance and savings from your new heater it is important to install the heater in a...

Page 4: ...odels are rated operation ONLY on 240V single phase 60Hz power Heaters are flow activated No Hartford loop is required After tightening both fittings at the water heater start the pump to allow water...

Page 5: ...no circumstances should you attempt to install repair or disassemble this heater without first shutting off all power to the heater directly at the fuse or breaker box WARNING Serious bod ily injury o...

Page 6: ...ill function only when there is sufficient flow through it 15 gpm 57 lpm minimum On the digital control panel press and hold the knob for five 5 seconds to check the flow rate in the unit ELS 0005 GRN...

Page 7: ...Table D Fault Codes 11 CONTROL Turn the control knob to set your desired temperature When the set tempera ture is reached the heater will go to idle and the elements will not draw power NOTE If the c...

Page 8: ...ng must be run in a separate conduit Remote wiring must not be run parallel to high voltage lines For runs of under 30 ft 9 m remote wiring should have stranded conductors with a minimum of 22 AWG 600...

Page 9: ...at least one wire lead disconnected from each element 6 10 to 7 11 Delay in energizing elements heater starts heating 1 minute after powering up and sufficient flow is recorded 1 minute 30 secs Turn...

Page 10: ...her conditions cold high winds Defective heating element Call the electric company Calculate temperature in heat rise hr Heater input kw x 410 divided by spa gallonage This does not take into account...

Page 11: ...OF THE CHAMBER 10K SENSOR INLET THERMISTOR OF THE CHAMBER 10K SENSOR CN3 CN4 GND 1 2 HI LIMIT 2 HI LIMIT 1 L1 L2 L1 L2 L1 L2 ELEMENT 2 1 3 1 2 1 2 1 2 WATER OUTLET SENSOR 150K WATER INLET SENSOR 150K...

Page 12: ...Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ISO 9001 REGISTERED QUALITY MANAGEMENT SYSTEM www raypak com...