background image

INSTALLATION & OPERATING

INSTRUCTIONS

Catalog No. 6100.53U

Effective: 09-28-09

Replaces: 11-11-08

P/N 240362 Rev. 22

FOR YOUR SAFETY:

Do not store or use gasoline or other flammable vapors and

liquids or other combustible materials in the vicinity of this or any other appliance. To

do so may result in an explosion or fire.

Models

ELS 552-2 & ELS 1102-2

Electric

SPA-PAK

Heater

Summary of Contents for els 552-2

Page 1: ...11 11 08 P N 240362 Rev 22 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance To do so may...

Page 2: ...0 Salt ppm 6000 Maximum 6000 Maximum 6000 Maximum Free Chlorine ppm 2 3 2 3 2 3 Total Dissolved Solids ppm 3000 Maximum 3000 Maximum 3000 Maximum Free Chlorine MUST NOT EXCEED 5 ppm Occasional chemica...

Page 3: ...g the holes provided The heater must be located where leakage of heat exchanger or connections will not damage the area adjacent to the heater or structure Water Connections The Spa Pak has 1 1 2 male...

Page 4: ...of the units Field Wiring Heater requires three wire service With 240 VAC there are two hot wires and a grounding conductor Even when metallic conduit is used the grounding conductor must be run to th...

Page 5: ...ize Wire Size including ground Size of Fused Disconnect amps ELS 1102 2 46 1 6 60 ELS 552 2 23 1 2 10 30 Use a reducer bushing Table A Wire Sizes for Field Connection L1 L2 MODEL ELS 552 2 ONLY SCHEMA...

Page 6: ...sumer Product Safety Commission rec ommends the following guidelines When using this electrical equipment basic safety precautions should always be followed including the following 1 READ AND FOLLOW A...

Page 7: ...d also damaging the heater If the pH drops below 7 2 the heater will be severely damaged This will result in cor rosion of the heat exchanger Heat exchanger damage resulting from chemical imbalance is...

Page 8: ...re switch Removing the Magnetic Contactor 1 Turn off electric power to heater at main discon nect 2 Remove wires from contactor 3 Remove screw holding contactor to cabinet Winterizing Damage will occu...

Page 9: ...ather Use spa cover Call electrician Check resistance element bundle 240V 11 kw 5 0 to 5 8 OHMS 240V 5 5 kw 10 0 to 11 6 OHMS Spa does not reach temperature Mis adjusted knob stop Low flow Re adjust k...

Page 10: ...0 F 1 1 8 1 0 0 t i m i L h g i H 7 8 Contactor Wire Kit 001813F 001813F 9 Thermostat Control 003346F 003346F 1 6 7 0 5 6 1 6 7 0 5 6 h c t i w S e l g g o T 0 1 F 2 1 8 1 0 0 F 2 1 8 1 0 0 t h g i L...

Page 11: ...11...