background image

Specifications:

Switching Capacity: 

  8 amps

STL200HB

STL200H1

STL200

Voltage:      

 120 volts

1000 watts Incandescent

500 watts Fluorescent

Detection Pattern: 

 50’ x 200˚

Time Adjustment: 

 5 seconds to 12 minutes

Power Consumption:      1 watt
Surge protection: 

  I. E.C. specs 

UL Listing:      

Raintight Photoelectric Switch

STL200 Installation Manual

STEALTH

Toll free fax:

e-mail:

Send a fax to

888 722-1232

Tech Help Line:

Call our experts

888 722-1000

Visit our website for

product info

Easy Answers

rclighting.ca:

Get answers promptly

sales@rclighting.ca

The designs of RC Lighting fixtures are protected under Canadian, U.S. and international intellectual property laws, © 2010 RC Lighting

Summary of Contents for STL200

Page 1: ...protection I E C specs UL Listing Raintight Photoelectric Switch STL200 Installation Manual STEALTH Toll free fax e mail Send a fax to 888 722 1232 Tech Help Line Call our experts 888 722 1000 Visit...

Page 2: ...ns Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equipment washer dryer or garage door openers Sensor must be below and as far as possible away from lights Se...

Page 3: ...night only Manual Override Mode to keep lights on Flip the switch twice slowly off on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset...

Page 4: ...ich time the controlled lights will go on At night the LED serves as a deterrent indicating a security device in operation Choosing a Location LED Detection Indicator 100 Top View 30 Side View 30 10 3...

Page 5: ...round Power In White White Red pigtail is only used to switch remote or additional fixtures 4 EZ Plate 1 Lights may turn on occasionally during rain snow and windstorms because the sensor is detecting...

Page 6: ...reference STL200 Power In Sensor Red Black White Ground 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high...

Page 7: ...l help is needed Control Panel 6 Start Finish 1 Check that lamps and fixtures work Compare wiring to the wiring diagram in this manual Check that the power is on 2 If installing during daylight rememb...

Page 8: ...Make sure heat from lights is not triggering sensor Make sure the sensor is below and as far as possible away from lights Technical Tips Lights Do Not Turn Off 7 WRONG OK OK WRONG 20 Safety Zone OK W...

Page 9: ...s are protected under Canadian U S and international intellectual property laws 2010 RC Lighting Caract ristiques Capacit de commutation 8 A Tension 120 volts Incandescence de 1 000 watts Fluorescence...

Page 10: ...ontinuer Tout le c blage doit tre conforme aux codes locaux de l lectricit et doit tre effectu par un lectricien comp tent La charge d clairage totale raccord e au Stealth ne doit pas d passer 8 A inc...

Page 11: ...5 secondes et 12 minutes R glage de l usine 5 8 minutes Sensibilit Accro t ou r duit la r action et la port e du d tecteur r glage de 30 100 R glage de l usine 100 Photocellule Derri re la lentille P...

Page 12: ...or repaired at our option if it proves to be defective in workmanship or materials within ten years from the date of original purchase For repair replacement return the product freight prepaid and ins...

Page 13: ...the lens with opaque weatherproof tape to create an Animal Alley 4 Although it is surge and transient protected the sensor may turn on occasionally during extreme voltage surges 5 A possible source of...

Page 14: ...quickly To fix move the sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Sensor will not detect until movement crosses zones Micro Adjust sensor by mov...

Page 15: ...tings will adjust operation during dusk and dawn 8 Your sensor is ready for operation See the Technical Tips pages 7 11 if additional help is needed 1 Check that lamps and fixtures work Compare wiring...

Page 16: ...sor away from reflective objects or move the objects and lower sensitivity 9 Self ballasted PL lamps may cause cycling on off 10 Check Solutions 2 4 5 6 and 7 under If Lights Do Not Turn Off 20 Safety...

Reviews: