7104, 7304

Aluminum & Wood Frames

4104, 4304

Aluminum Frames

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-1/4

1.250

31.75

B

4-7/8

4.875

123.83

C

3-3/8

3.375

85.73

D

7/8

.875

22.23

E

3/8

.375

9.53

F

1/8*

.125*

3.18*

G 1-11/16

1.688

42.86

Vertical

Vertical Vertical

X

C/L

C/L

C/L

Door

Door

Door

R

5/32

.156

3.97

K

4-1/8

4.125

104.78

M 12-24

Vertical Centerline

of Door**

I N S T A L L A T I O N

Electric Strikes

4 / 7 Series

7105, 7305

Aluminum & Wood Frames

4105, 4305

Aluminum & Wood Frames

IS47

R07/06DA

P10/06DA

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-1/8

1.125

28.58

B

5-7/8

5.875

149.23

C

3-3/8

3.375

85.73

D

7/8

.875

22.23

E

1/4

.250

6.35

F

1/8*

.125*

3.18*

G

1-11/16

1.687

42.86

Vertical Vertical Vertical

X

C/L

C/L

C/L

Door

Door

Door

R

5/32

.156

3.97

K

5-3/8

5.375

136.53

M

12-24

Vertical Centerline

of Door**

1. Determine the vertical centerline of the door lock

face and the horizontal centerline of the latch.

IMPORTANT

: When determining the horizontal

centerline observe the following:

FOR MORTISE LOCKS

: Align the angled ramps of

the lip bracket with the deadlock trigger of the
mortise latch.

FOR CYLINDRICAL LOCKS

: Align the center of the

latch with the center of the strike opening.

2. Transfer both the horizontal and vertical centerlines

to the doorframe.**

3. Prepare the doorframe for cutting as per the

appropriate drawing.

4. If required, install “no weld” mounting brackets as

per the instructions included with the mounting
brackets in the hardware pack.

5. Attach the strike insert (coil unit or “motor”) to the

lip bracket with the screws provided.

6. Attach the strike faceplate to the lip bracket with the

screws provided. (It may be desirable to leave these
screws slightly loose to facilitate insertion into the
doorframe.

7. Connect the incoming wiring from the power supply

to the terminal screws on the strike insert. RCI door
strikes are not polarity sensitive although be certain
to observe proper polarity if a suppression diode is
required for access control applications.

8. Install the door strike in the doorframe using the

screws provided.

Instructions

NOTE

: Specifications subject to change without notice.

*

Dimension F

is measured from face of mounting tab to face of frame and equates to the thickness of the frame material.

**

Dimension X

on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be

necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to
relocate the vertical centerline an appropriate distance on the frame.

For wood frame door installations, substitute #12 wood screws for dimension M.