background image

©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com

USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON  N1T 1j6 

 PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: SAlES@RUTHERFORDCONTROlS.COm

IS9212i

Pcn13031

R04/13cA

I N S T A L L A T I O N

9212i

Stand-Alone Keypad

Instructions

Features:

• 4 Independent Outputs

• 4 Independent Timers

• All Outputs Assignable by Code

• On board 5 Amp Form C Relay

• 120 Users

• Remote Triggering Input

• Keypad Programmable

Memory

Non-volatile EEPROM memory means your codes and 

programming will be there whether you remove power for 

5 minutes or 5 years.

Programming

All programming is accomplished entirely from the 

front of the keypad. LED or Sounder guidance makes 

programming easy, and changing codes a matter of 

seconds for an authorized user.

Codes

The RCI keypads allow up to 120 individual user codes 

to be valid. Codes may be from 1-6 digits in length 

and digits may be repeated. The Master Code is always 

assigned to user location one (1).

Main Relay

This is a 5 Amp (10 Amp surge) Form-C relay which can 

be toggled or timed from 1 to 90 seconds-by code.

Auxiliary Outputs

Auxiliary outputs can be individually timed from 1 to 90 

seconds or act as a toggle switch, and may be triggered 

individually or in combination-by code. The three auxiliary 

outputs provide a 50mA sink to ground when activated.

Remote Triggering Input

This normally open loop that by default operates the Main 

Relay upon activation and can be programmed to trigger 

any combination of outputs. Upon a momentary closure, 

the selected outputs will energize for their programmed 

time. The main relay (if selected) will energize for the 

same time period as the Master Code. This feature is 

especially useful when controlling an electric locking 

device.

Keypress Feedback / Audible Keypress

The RCI keypads will acknowledge a keypress by 

momentarily illuminating the yellow LED. This can be 

turned off through programming.

Keypad Active Output

The RCI keypads can be programmed to energize a 

voltage output whenever a key is touched. This can be 

used to turn on accessories such as lights, CCTV camera, 

or notify a guard.

Auto-Entry

This feature is used when the need for the code not to 

be followed by the * key is desired. The user only needs 

to enter their code number and the relay will activate for 

the programmed relay time. To use this feature, the user 

codes must be the same length as the master code.

Technical Notes: 

To avoid ESD (Electro-Static Discharge) from interfering 

with the operation of the RCI keypad, ground the negative 

terminal of the keypad to earth ground. If the power 

supply can not be grounded, then the case should be 

grounded. For 24VDC operation, remove jumper J2 (see 

Fig. 5).

Packing Checklist:

9212i Keypad

Ten (10) Conductor Wiring Harness (1)

Slotted Screws (2)

Security Screws (2)

Installation

Diode (1)

NOTE: As with any electronic product, the 9212i may be subject to irregularities in the AC power line. This can cause malfunction or unstable operation. 

Connecting the 9212i to a suitable DC power supply will limit the effects of AC fluctuation on the keypad.

 

Voltage 

Current Rating 

 

Temperature 

Output

  12-24 VAC/VDC 

@ 12VDC  8mA typ – 35mA w/ relay energized 

-20°F to 130°F (-28°C to 54°C) 

Main relay: 5A; form-C @24VDC; 10A surge 

 

 

@ 24VDC  16mA typ – 45mA w/ relay energized 

 

Outputs 2-4 are 50mA neg voltage outputs

Summary of Contents for 9212i

Page 1: ...losure the selected outputs will energize for their programmed time The main relay if selected will energize for the same time period as the Master Code This feature is especially useful when controlling an electric locking device Keypress Feedback Audible Keypress The RCI keypads will acknowledge a keypress by momentarily illuminating the yellow LED This can be turned off through programming Keyp...

Page 2: ...low LED Press 99 master code Flashes slowly 2 To change master code Press 1 new master code Flashes fast Repeat new master code Flashes slowly If main relay time must be changed substitute option 2 from Programming Options chart for step above 3 To add change second code Press 2 new user code Flashes fast Repeat new user code Flashes slowly 4 To add change third code Press 3 new user code Flashes ...

Page 3: ... 1 0 14 Turn auto entry on Press 30 2 1 15 Turn auto entry off Press 30 2 0 16 Turn keypad active output on4 Press 43 0 99 17 Turn keypad active off Press 43 0 00 18 Erase keypad memory reset defaults Press 46 00000 00000 19 Energize selected output s with a user code5 Press 59 outputs i e 1 2 or 2 3 etc user location new code repeat code e g User 2 code of 4321 energize outputs 2 3 Press 59 23 02...

Page 4: ...magnetic Lock Exit Button N O TS1 V V N C C N O Brown White Orange Fig 1 Basic access control w an electromagnetic lock Exit Button To Alarm Panel Closed Circuit Loop COM N O N O TS1 V V N C C N O Brown White Orange Fig 3 Shunting a Normally Closed N C Zone 4 2013 Rutherford controls www rutherfordcontrols com USA 2517 SQUADRON COURT SUITE 104 VIRGINIA BEACH VA 23453 Canada 210 shearson crescent c...

Page 5: ...result if incorrectly inserted Fig 6 9212i Wiring Harness WARNING Plug this harness in with the leads facing down Permanent damage may result if incorrectly inserted Wire Color Wire Function White Not Used White Blue Output 3 50mA sink to ground White Red Output 2 50mA sink to ground Orange Output 4 panic 50mA sink to ground Brown Remote Triggering Input REX White Orange Remote Triggering Input RE...

Reviews: