background image

I N S T A L L A T I O N

9321/23

Easy Read-Prox

®

 Reader

Fig. 1

Fig. 2

©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com

usA: 2517 sQuAdRon couRt, suIte 104, VIRGInIA BeAch, VA 23453 • cAnAdA: 210 sheARson cRescent, cAmBRIdGe, on  n1t 1j6 

 Phone: • 1.800.265.6630 • 519.621.7651 • fAX: • 519.621.7939 • e-mAIl: sAles@RutheRfoRdcontRols.com 

Is9321/23

R08/13cA

In or Out...we make it Easy! 

®

Where to install proximity readers

Low to high traffic doors

Interior or exterior doors

Narrow door frames

Inside walls

Architecturally sensitive installations

Where NOT to install proximity readers

Behind metal – RF will not penetrate

On a ferrous metal surface – diminishes read range

Near TVs or monitors – RF will interfere with reader

NOTE:  READER IS WEATHER RESISTANT. Do not apply sealant or gaskets to the back of the reader, as this may cause  

condensation build up and adversely affect reader operation.

9321 Slimline

1.  Select appropriate space on wall for reader installation.  

Ensure that there are no hidden electrical hazards prior to 

drilling. 

2.  Drill hole for reader wiring to pass through.

3.  Remove changeable cover from reader if necessary. Cover 

is removed by prying off from the bottom of cover only.

4.  Pass the readers 8 wires through hole.

5.  Hold reader against wall with LED’s at bottom, mark 

position of three mounting holes.

6.  Drill the three mounting holes as appropriate for the type of 

fasteners being used. 

7.  Install / level the reader and secure with three mounting 

screws.

8.  Install removable cover by engaging top tab and pivoting 

cover down over reader. Cover should snap in place when 

installed properly.

9.  Cover is secured with single screw (provided) on lower 

edge of cover.

  Important: Cover screw must not be longer than 1/4” or 

internal damage will result, voiding warranty.

9323 Micro

1.  Select appropriate space on wall for reader installation.  

Ensure that there are no hidden electrical hazards prior to 

drilling. 

2.  Holding reader back plate against wall, mark position for 

two screw holes and center hole for reader.

3.  Drill center hole 13/16” (7/8” max) in diameter. If wall is 

not hollow, ensure depth of the hole is at least 2-3/4” deep 

to prevent damaging reader/wiring.

4.  Drill two smaller mounting holes as appropriate for type of 

fastener being used.

5.  If necessary, drill hole through wall for wiring to pass 

through.

6.  Screw back plate onto reader until flush with front of 

reader.

7.  Pass reader wires through hole and out other side as 

appropriate.

8.  Insert reader into hole being careful not to damage wiring.  

Secure back plate with two screws provided.

9.  Snap the appropriate colored cap over the back plate by 

engaging one side and press the other side until it snaps 

securely in place.

Mounting Instructions

Summary of Contents for Easy Read-Prox 9321

Page 1: ... LED s at bottom mark position of three mounting holes 6 Drill the three mounting holes as appropriate for the type of fasteners being used 7 Install level the reader and secure with three mounting screws 8 Install removable cover by engaging top tab and pivoting cover down over reader Cover should snap in place when installed properly 9 Cover is secured with single screw provided on lower edge of...

Page 2: ...r in parallel 5 Reader operates on 12VDC only Connect reader to power transformer and electric lock as shown in Fig 6 or Fig 7 Note Unit requires a filtered and regulated power source for proper operation See our line of power supplies and transformers for options to use Fig 3 Fig 4 Micro reader surface mounted onto wall using back plate The plastic end cap is placed over the exposed end of the re...

Page 3: ... Reader Proximity Micro Reader or 2013 Rutherford controls www rutherfordcontrols com USA 2517 SQUADRON COURT SUITE 104 VIRGINIA BEACH VA 23453 Canada 210 shearson crescent cambridge on n1t 1j6 PHONE 1 800 265 6630 519 621 7651 FAX 519 621 7939 e mail sales rutherfordcontrols com or Red Proximity Slimline Reader ...

Page 4: ... To Enroll another Card Pack 1 Additional Card Pack s may be added as needed 2 To enroll an additional Card Pack first present the Enrolment Card from any currently enrolled Card Pack to reader 3 Follow this by presenting the Enrollment Card from new Card Pack 4 New Card Pack is now enrolled Hardwire Reset Instructions The proximity reader will remember its settings and details of card validity in...

Reviews: