Fail Locked = Fail Secure = FL AC = Alternating Current DC = Direct Current
Intermittent Duty = Energized less than 1 minute with 1:5 duty ratio Continuous Duty = Energized 1 minute or more
I N S T A L L A T I O N
VR165
ISVR165
®
Important: Adjust strike as indicated in steps 7 & 8 to ensure proper functionality. Ensure the exit device functions as
intended for life safety concerns by verifying electric strike and exit device compatibility. Maximum latch projection is
essential to obtain full engagement.
This product is Fail Locked only. The local Authority Having Jurisdiction shall be consulted with regard to the use of
selected panic hardware to ensure emergency exit from the secured area.
Installations of this Vertical Rod strike qualify as “Indoor Use Only” when not continuously exposed to an outdoor
environment.
Catalog Specifications
MODE
VOLTAGE CURRENT
DUTY
PEAK AMPS
OHMS
Fail Locked
12V
AC
Intermittent
0.20
22
Fail Locked
12V
DC
Continuous
0.45
22
Fail Locked
24V
AC
Intermittent
0.48
22
Fail Locked
24V
DC
Continuous
0.24
89
Fail Locked
11-16V
AC
Intermittent
0.18-0.27
22
SURFACE MOUNTED VERTICAL ROD STRIKE
Dimensional Details
© 2016 RUTHERFORD CONTROLS INT’L
WWW.RUTHERFORDCONTROLS.COM • PHONE: 1.800.265.6630 • FAX: 1.800.482.9795 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM
"
2 14
(57.0mm)
8 "
(41.5mm)
1 5
HOLES
MOUNTING
HORIZONTAL
ADJUSTMENT
LOCK DOWN
CLAMP
"
1 34
(44.5mm)
"
5 12
(139.7mm)
6 18 "
(155.6mm)
3
4 "
(19.0mm)
1 58 "
(42.0mm)
M8 SCREW
R09/16TG-2
®
UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I