background image

User manual

S20 

automatic door systems - this is record!

Translation of the original manual

Summary of Contents for S20 Series

Page 1: ...User manual S20 automatic door systems this is record Translation of the original manual ...

Page 2: ...2 3 Protection during opening cycle 11 2 3 1 DIN aluminium finishing profiles 12 2 3 2 Safety distances 12 2 3 3 Protective screen 13 2 3 4 Presence sensing device 13 2 4 General and additional requirements 13 2 4 1 Detection zone for sensor activation 13 2 4 2 Additional requirements for doorsets in escape routes and emergency exits 14 2 4 3 Signage 14 2 4 4 Guards 14 2 4 5 Commissioning and info...

Page 3: ...des BDE M 22 6 5 1 Operating mode display 23 6 5 2 Reset Button 23 6 6 Locking the control panel with the keyboard 23 6 7 Locking the control unit with a key option 24 6 8 Self test redundancy test of operator 24 6 8 1 When is a self test carried out 24 6 8 2 Resetting the alarm 24 7 Servicing and maintenance 25 7 1 General remarks 25 7 2 Monthly inspection work to be carried out by the operating ...

Page 4: ...or in emergency 31 8 4 1 Emergency opening with current supply 31 8 4 2 Emergency opening in case of power failure with a back up battery optional 31 8 4 3 Emergency operating using Bowden cable Option 31 9 Taking out of service and disposal 33 9 1 Taking out of service 33 9 2 Dismantling and disposal 33 ...

Page 5: ...ere injury or death DANGER Against an imminent or latent hazardous situation that could lead to electric shock and cause serious injury or death Intended purpose of use The system is designed exclusively for use as a pedestrian passage The installation may only occur in dry areas If there are deviations then proper waterproofing and water drains will be required on site Any other application or us...

Page 6: ...lay with the device or its regulating and or control devices including remote controls IMPORTANT When using motion detectors make sure that no moving objects such as flags plants etc enter the detection areas of the motion detectors IMPORTANT In order to avoid malfunctions the system must NOT be disconnected from the mains overnight IMPORTANT If malfunctions that endanger the safety of individuals...

Page 7: ...put them out of operation Do not connect the power supply until all work has been completed Work on the electrical system must only be carried out by qualified personnel Intervention rules on sites Subject to general labor laws IMPORTANT Before starting with inspection and maintenance it is necessary to ensure that a side entrance can be used by third parties It is highly recommended to have a ped...

Page 8: ... keeping We recommend obtaining a service agreement Personal protective equipment Personal protective equipment is used to protect persons from adverse effects on safety and health Personnel must wear personal protective equipment during the various work activities on and with the system Personal protective equipment is explained below Hearing protection is used to protect the hearing from noise A...

Page 9: ...In addition to protective equipment for specific work the work site may require other protective equipment for example a harness In hygiene protected areas special or additional requirements of personal protective equipment may be required These requirements must be considered when choosing personal protective equipment If there is any uncertainty regarding the choice of personal protective equipm...

Page 10: ...is hinged or pivoted from the upright frame part Sliding doors Powered pedestrian door with one or more wings which moves horizontally and parallel in its guides to the adjoining construction Powered pedestrian door with low energy drive Powered pedestrian door with limited kinetic energy Pivot fitting Break Out System whereby door wings and or side screens can be pushed open ma nually in the dire...

Page 11: ...be detected from both sides of the door on the whole travel area of the doorset The reference body 700x300x200 mm must be detected at any point of an area as wide as the doorway and extending over a distance of 200 mm on both sides of the door axle Reference body Solution Outside 3 x Ixio DT3 Inside 1x Ixio DT3 2x Ixio ST NOTICE A combination sensor Ixio DT3 Performance Level d must be used on the...

Page 12: ...the adjacent parts of the surroundings must be respected depending on the distance X between the front part of the door leaf and the fixed side screen see Figure a In that case the impact hazard and the hazard concerning crushing of the body are considered to be not relevant and no more safeguard is required For telescopic doorsets the reference leaf for the measurement is considered to be the one...

Page 13: ...eed when somebody wants to go through the doorway Alternatives to IXIO ST IMPORTANT Only products authorised according to EN 13849 1 2006 Performance Le vel c may be used Examples IRIS ON BEA OA AXIS T OPTEX PrimeScan Bircher Reglomat The wiring takes place on the programmable inputs of the STM or on the FEM 0 with parameterisation of the SIO function Book B7 Commissioning Chapter STM 20 STM 20 DU...

Page 14: ...closures covers enclosing guards or fixed protection leaves shall be designed so that 1 Persons cannot reach any danger point up to a height of 2 5 m above floor level 2 They can only be removed or opened with the aid of a tool Solution This requirement can be met by using the option lockable casing Commissioning and information for use The operator shall be instructed during commissioning Moreove...

Page 15: ...system The illustrations are for basic understanding and may differ from the actual presentation Specific re presentations are contained in the drawings Document identification Name BAL_S20_EN_1V0_REC_121 006454590 Version V1 0 Article nr 121 006454590 Publication date 02 2020 Copyright The copyright of the instructions remain at BLASI GmbH Carl Benz Str 5 15 D 77972 Mahlberg It is prohibited to r...

Page 16: ...er The manufacturer of the system is the company Blasi GmbH Carl Benz Str 5 15 D 77972 Mahlberg Operator The operator of the system is referred to as the owner regar dless whether he operates it as owner or discloses it to a third party Personnel All individuals referred to as personnel are those who perform any task on or with the system during its lifespan and are quali fied to perform such task...

Page 17: ...7 33 Description General view Example of 1 wing sliding door Pos Components Pos Components 1 Top guide 5 Combination sensor 2 Wall connection side panel 6 Wall connection wing side 3 Side panel 7 Wing 4 Emergency release unlock 8 Drive complete 4 4 1 ...

Page 18: ...Equally the door wing will stop immediately if the door hits an obstacle during the opening process The opening process will start anew after 3 seconds at extra slow speed Security sensors side panel The opening area of the door wing inside is monitored by security sensors The function of the sen sors is tested before each opening If there is detection during the opening process the door will stop...

Page 19: ...ing width A 800 mm to 3ʹ000 mm Passage height G max 3ʹ000 mm Max Door leaf inclination 10 Underfloor drive Width 330 mm Underfloor drive Depth 180 mm Underfloor drive Length 1ʹ800 mm to 6ʹ500 mm Max Door leaf weights Typ STA20 SU STA20 SU DUO RED STA22 SU DUO RED D STA 2 120 kg 2 150 kg 2 200 kg E STA 1 150 kg 1 200 kg 1 250 kg Electrical connection data Mains voltage 100 240V AC STA 20 115V AC Se...

Page 20: ...losed and locked if there is a locking de vice System remains locked even in case of power failure Reduced ope ning width Unobstructed access through the system in both direc tions Reduced opening width NOTICE The reduced opening width is also effective with operating modes One way and Continuously open Selection of special functions Key operation Function Display Description Manual mode Press key...

Page 21: ...on via the BDE V illustrated below Control unit BDE V night locking The door may only be locked by an authorised person responsible for the key after this one has made sure that nobody else is on the premises Locking via external clock timer or control system is not allowed Key Operating mode Symbol Function Automatic Door opens unhin dered from inside and outside Maximum opening width summer ope ...

Page 22: ...g modes One Way and Continuously open Selection of special functions RED Key Function Display Description Single opening Door is closed and locked 1 keystroke unlocks the door An opening closing cycle is performed Once closed door locks again NOTICE Automatic doors on escape routes RED installations cannot be manoeuvred by hand for safety reasons Selection of operating modes BDE M The mechanical o...

Page 23: ...n This hidden button will be actuated with a 25 mm long paper clip Therefore there is a little hole in the middle of the logo If the reset button will be pressed for about 5 seconds a software reset will happen The pre set set tings remain unaffected Locking the control panel with the keyboard IMPORTANT Standard EN 16005 requires protection of the selection of the mode of ope ration of pedestrian ...

Page 24: ... Self test redundancy test of operator When is a self test carried out In certain conditions the door automatically performs a so called redundancy test i e the door car ries out a slow opening and closing cycle thereby checking safety functions Such function is executed in particular in case of a change of the operating mode as specified below From Continuously open to another one From Locked to ...

Page 25: ...ion are cleaned and adjusted Re levant fixing screws are controlled and retightened if necessary Then functional testing is carried out for switching devices drives control units force or energy sto ring devices or command controllers The safety devices are adjusted and all the motion sequences including the final points are set A test run with final overall control of the door system is executed ...

Page 26: ...nt the door from closing Therefore en sure that the indoor air is dehumidified or wipe the ex ternal sensor dry if necessa ry The sensor must cover the entire passage width The door is opened early and at an adequate speed to al low an unimpeded passage Door wings side parts Check the condition of the panes Check the condition of the gaskets profiles No damaged panes No torn out gaskets energy los...

Page 27: ...rt cigarette butts etc The door leaf must be pro perly guided The movement of the door must not be obstructed by dirt Drive guard cover Check the fastening of the drive guard cover It must be completely closed and reliably engage in the hinges Protective wing optional de pending on national regulations Check the mechanical condi tion of the protective wing In particular check the clo sing mechanis...

Page 28: ... contact the relevant service centre Before you call write down the data displayed on the BDE D This information provides the tech nician with important informations for troubleshooting If several status messages are active at the same time they are numbered e g error 1 2 Pressing the E button permits to navigate from one error message to the next one Example Which information Procedure How displa...

Page 29: ...case please inform our service centre Manual opening without manual release Initial position door is blocked and locked in closed position in de energised state Opening the drive fairing and cover plates unscrewing Note Only open the cover plates in the middle to get to the locking mechanism To be on the safe side unplug the power cord from the wall outlet The socket outlet is located under the dr...

Page 30: ...on Door is closed and locked if applicable Inform the service point telephone number is displayed on the BDE D NOTICE If the door cannot be moved by hand and locked please follow the steps descri bed as follows Manual closing Step 2 If the efforts described in Step 1 to manually close and lock the door are unsuccessful this is a seri ous fault Proceed as follows Set the door on the control unit to...

Page 31: ...a pulling different procedures depending on the version of the switch Emergency opening in case of power failure with a back up battery optional If a back up battery is fitted and parametrized as Battery operation all functions of the automatic door will continue to be available In case of a power failure emergency opening is ensured by a back up battery that opens the door once except if the prog...

Page 32: ...o 31 Emergency stop The door can be slid open by hand Closing and locking the door Activate the emergency opening This causes the locking device to be unlocked Slide the door manually into the closed position Keep the door leafs in the closed position Close the unlocking flap The door is now locked Check manually if the door is really locked NOTICE Same procedure for the other operating elements 8...

Page 33: ...tems can be completely disassembled in reverse order The automatic door mainly consists of the following materials Aluminum Linking profiles Gearbox Door wing profiles and side profiles Various profiles and small parts Drive panel Steel iron parts Stainless steel casing Floor panel Box recess for floor installation Optional spacer or reinforcement profiles Gear components springs Various small par...

Page 34: ...ess Centre Unit 40 Annexe 2 Technology Drive Batley Wf17 6ER UK Southern Office 17 Invincible Road Farnborough Gu14 7QU UK tel 44 1698 376411 fax 44 1698 376422 info recorduk co uk www recorduk co uk record global export agtatec ltd Allmendstrasse 24 8320 Fehraltorf Switzerland tel 41 44 954 91 91 e mail export record global www record global Headquarters agtatec ltd Allmendstrasse 24 8320 Fehralt...

Reviews: