background image

For Sales and Support, Contact Walker EMD • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800 • www.walkeremd.com

DESCRIPTION

The CUB7P is an 8-digit miniature programmable counter with large 0.35

inch (8.90 mm) high digits. It has an LCD read-out available in Positive Image
Reflective, Negative Image Transmissive with yellow/green backlighting, or red
backlighting. Backlight units require an external 9 to 28 VDC power supply. 

The CUB7P is available in either Low Speed Contact or High Speed Logic.

The Contact versions (CUB7P0xxx) operate from a switch contact or an NPN
open collector transistor. The Logic versions (CUB7P2xx) operate from 3 VDC
logic output or from an NPN open collector transistor. 

The CUB7P has a programmable prescaler that can be set for any value

between 0.0001 and 1.9999. The decimal point position can be set anywhere
from 0 (no D.P.) to 0.000000 or no Leading Zero Blanking. Both the prescaler
and DP selection are accessed using the front panel PGM and RESET push
buttons. See Programming for details. Note that the count, prescaler and DP
values will be lost if the battery is removed. See BATTERY INSTALLATION
for additional information.

The CUB7P counters use a CMOS LSI chip, mounted on a gold-plated

substrate, that is electrically connected by ultrasonic wire-bonding. Proven
micro-electronic assembly and manufacturing techniques provide these units
with the reliability and dependability required for industrial service.

The CUB7P series is housed in a lightweight, high impact plastic case with a

clear viewing window. The sealed front panel with the silicone rubber buttons
meets NEMA 4X/IP65 specifications for wash-down and/or dusty
environments, when properly installed.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators

not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.

1

O

LCD, POSITIVE IMAGE REFLECTIVE OR NEGATIVE IMAGE

TRANSMISSIVE WITH YELLOW/GREEN OR RED LED
BACKLIGHTING (9-28 VDC power supply required for versions with
LED backlighting)

O

AVAILABLE WITH LOW SPEED CONTACT (30 Hz MAX.), HIGH

SPEED LOGIC (10 KHz MAX.) 

O

PRESCALER FROM 0.0001 TO 1.9999

O

SELECTABLE DECIMAL POINTS

O

REPLACEABLE INTERNAL LITHIUM BATTERY PROVIDES UP

TO 6 YEARS OF UNINTERRUPTED OPERATION (Battery Included)

O

WIRE CONNECTIONS VIA SCREW CLAMP TYPE TERMINALS

O

FRONT PANEL AND REMOTE RESET INPUT

O

NEMA 4X/IP65 SEALED FRONT BEZEL

O

BOTH FRONT PANEL PROGRAM AND RESET BUTTONS ARE

INDIVIDUALLY ENABLED

MODEL CUB7P PROGRAMMABLE  ELECTRONIC 8-DIGIT COUNTER

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation

is 2.15" (54.6) H x 3.00" (76.2) W.

PANEL CUT-OUT

Bulletin No.  CUB7P-B
Drawing No.  LP0647
Released  3/07

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

C

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

51EB

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

BNL10000

CUB7P220

CUB7P210

CUB7P200

CUB7P020

CUB7P010

CUB7P000

PART NUMBER

Counter; Positive Image Reflective

Counter, w/Yel-Grn Backlighting

Counter; w/Red Backlighting
Counter; Positive Image Reflective

Counter, w/Yel-Grn Backlighting

Counter; w/Red Backlighting
Replacement 3 V Lithium Battery

BNL

HIGH SPEED

LOGIC INPUT

*CUB7P

LOW SPEED

CONTACT INPUT

MODEL NO. DESCRIPTION

* Battery is included with unit.

ORDERING INFORMATION

Summary of Contents for CUB7P

Page 1: ...s that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not...

Page 2: ...erature to 40 C Must use NEC Class 2 or SELV rated power supply 4 SIGNAL INPUT LS terminal 4 See Count Edge under Programming for incrementing edge of input signal Contact Input CUB7P0xx 30 Hz max fro...

Page 3: ...uch as ferrite suppression cores is effective Install them on Signal and Control cables as close to the unit as possible Loop the cable through the core several times or use multiple cores on each cab...

Page 4: ...when properly installed The units are intended to be mounted into an enclosed panel The viewing window and reset button are factory sealed for a washdown environment A sponge rubber gasket and mounti...

Page 5: ...max voltage drop 0 5 V when ON The OFF state leakage current must be less than 2 A Note The RC protection circuit on the RST Input causes a delay of approximately 15 msec in Reset response L S INPUT C...

Page 6: ...t versions of the CUB7P require an external 9 to 26 VDC power supply The external supply is connected between the V and common terminals as shown in the drawing APPLICATION TOTAL YARDS OF MATERIAL A f...

Page 7: ...For Sales and Support Contact Walker EMD Toll free 800 876 4444 Tel 203 426 7700 Fax 203 426 7800 www walkeremd com 7 This page intentionally left blank...

Page 8: ...or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be...

Reviews: