background image

1

CONVERTS NUMEROUS PROTOCOLS SIMULTANEOUSLY

EXTENSIVE BUILT-IN DRIVER LIST ALLOWS EASY DATA

MAPPING TO PLCs, PCs, AND SCADA SYSTEMS

10 BASE-T/100BASE-TX ETHERNET PORT SUPPORTS FOUR

SIMULTANEOUS PROTOCOLS

INDEPENDENT SERIAL PORTS PROVIDE VIRTUALLY

UNLIMITED INTEGRATION METHODS

SUPPORTS UP TO NINE PROTOCOLS SIMULTANEOUSLY(with

expansion card)

GENERAL DESCRIPTION

The Data Station Plus was designed to act as a nexus for industrial data

collection and management. With three built in serial ports and a 10 Base-T/100
Base-TX Ethernet port, the unit performs protocol conversion, allowing
disparate devices to communicate seamlessly with one another. The Ethernet
port supports up to four protocols simultaneously so even Ethernet to Ethernet
conversion may be performed.

The CompactFlash card allows new configuration files to be loaded into the

Data Station Plus. The USB port may be used for blazing fast file downloads, or
to mount the Data Station’s CompactFlash card as an external drive to your PC.
The Data Station’s DIN rail mounting saves time and panel space and snaps
easily onto standard top hat (T) profile DIN rail.

SOFTWARE

The Data Station is programmed with Crimson

®

2.0 software for Windows

®

2000 or later platforms. The software is an easy to use graphical interface which
can be purchased as part of a kit that includes a manual and cables, or
downloaded free of charge from www.redlion.net.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller. An independent and
redundant temperature limit indicator with alarm outputs is strongly
recommended.

CompactFlash is a registered trademark of CompactFlash Association.

MODEL DSPLE – DATA STATION PLUS

Bulletin No.  DSPLE-C
Drawing No.  LP0671
Released  03/09

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to 

installation and operation of the unit.

DIMENSIONS  In inches (mm)

FOR USE IN HAZARDOUS LOCATIONS:

Class I, Division 2, Groups A, B, C, and D

3PWL

PROGRAMMABLE 

CONTROLLERS

CC

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

34AD

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2

THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I,
DIVISION 2, GROUPS A, B, C, D, OR NON-HAZARDOUS
LOCATIONS ONLY

Summary of Contents for Data Station Plus

Page 1: ...e which can be purchased as part of a kit that includes a manual and cables or downloaded free of charge from www redlion net SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not s...

Page 2: ...s steel Installation Category I Pollution Degree 2 8 POWER CONNECTION Removable wire clamp screw terminal block Wire Gage Capacity 24 AWG to 12 AWG Torque 4 45 to 5 34 in lb 0 5 to 0 6 N m 9 MOUNTING Snaps onto standard DIN style top hat T profile mounting rails according to EN50022 35 x 7 5 and 35 x 15 10 CERTIFICATIONS AND COMPLIANCES SAFETY UL Listed File E302106 UL508 CSA 22 2 No 14 M05 LISTED...

Page 3: ...evices or equivalent are recommended Ferrite Suppression Cores for signal and control cables Fair Rite part number 0443167251 RLC part number FCOR0000 TDK part number ZCAT3035 1330A Steward part number 28B2029 0A0 Line Filters for input power cables Schaffner part number FN610 1 07 RLC part number LFIL0000 Schaffner part number FN670 1 8 07 Corcom part number 1 VR3 Visit RLC s web site at www redl...

Page 4: ...G USB PG RS232 PG ETHERNET WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE NON HAZARDOUS INPUT AND OUTPUT I O WIRING MUST BE IN ACCORDANCE WITH CLASS I DIV 2 WIRING METHODS AND IN ACCORDANCE WITH THE AUTHORITY HAVING JURISDICTION ...

Page 5: ...Bradley equipment PORT 3 ETHERNET CONNECTION RS232 RS485 5 DATA STATION PORT PIN OUTS TROUBLESHOOTING If for any reason you have trouble operating connecting or simply have questions concerning your new Data Station contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion n...

Page 6: ... 0 and is located in the folder C Program Files Red Lion Controls Crimson 2 0 Device after Crimson 2 0 is installed This may have already been accomplished if your Data Station was configured using the USB port Once the driver is installed connect the Data Station to your PC with a USB cable and follow Mounting the CompactFlash instructions in the Crimson 2 0 user manual Note The USB port is for s...

Page 7: ...t lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 0 User Manual Transmitting GREEN Receiving RED INDICATION LED Note LEDs are not available on the Programming Port RS232 PG Link Established YELLOW Solid 100 BASE TX Communications AMBER 10 BASE T Communications GRE...

Page 8: ...uyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those ex...