background image

1

 

z

PROTOCOL CONVERSION FEATURE CONVERTS NUMEROUS 

PROTOCOLS SIMULTANEOUSLY

 

z

COMPACTFLASH

®

 SLOT ALLOWS PROCESS DATA TO BE 

LOGGED DIRECTLY TO CSV FILES

 

z

VIRTUAL HMI OFFERS BUILT-IN PC-BASED SCADA 

FUNCTIONALITY

 

z

250+ COMMUNICATIONS DRIVERS FOR COMMUNICATING 

DIRECTLY WITH PLCs, DRIVES, ETC.

 

z

BUILT-IN WEBSERVER ALLOWS REMOTE VIEW OR CONTROL 

FROM ANY INTERNET CONNECTED PC

 

z

PROVIDES EMAIL AND SMS TEXT MESSAGE ALERTS

 

z

SYNCS DATA LOGS TO FTP SERVERS AND MICROSOFT SQL 

SERVER

®

 

z

USB HOST CAPABILITY ALLOWS PROGRAMMING AND LOG 

FILE STORAGE USING THUMB DRIVES AND ALLOWS 

CONNECTION TO OTHER USB DEVICES

 

z

10 BASE-T/100 BASE-TX ETHERNET CONNECTION CAN 

CONNECT TO AN UNLIMITED NUMBER OF DEVICES VIA TEN 

PROTOCOLS SIMULTANEOUSLY

GENERAL DESCRIPTION

The DSPZR was designed to act as a nexus for industrial data collection and 

management. The unit offers multiple protocol conversion, data logging and 

remote machine access. With three built in serial ports and a 10 Base-T/100 

Base-TX Ethernet port, the unit performs protocol conversion, allowing 

disparate devices to communicate seamlessly with one another. The Ethernet 

port supports up to ten protocols simultaneously using C3, so even Ethernet to 

Ethernet protocols can be converted.

The DSPZR leverages over 250 communications drivers via three independent 

serial ports and an Ethernet port, to connect and collect data from virtually any 

PLC, drive, bar code scanner, etc. 

The DSPZR’s built-in data-logger will log tags at user-programmable rates, 

and automatically time/date stamp them. The information is stored in open CSV 

file format, allowing you to access them with virtually any application. The 

DSPZR can synchronize the log files with any FTP server and/or Microsoft’s 

SQL Server for further analysis.

The CompactFlash card allows data to be collected and stored for later 

review. The files are stored in simple CSV file format allowing common 

applications, such as Microsoft Excel and Access, to view and manage the data. 

The CompactFlash card may also be used to load new configuration files into 

the DSPZR

The DSPZR extends production monitoring to remote personnel by providing 

email and text alerts, and its built-in webserver allows information to be 

monitored via any networked PC or smart-phone. If enabled, remote personnel 

can take partial or full control of the system remotely, allowing a maintenance 

person to effect changes without a site visit.

The USB port may be used for blazing fast file downloads, or to mount the 

DSPZR’s CompactFlash card as an external drive to your PC. The DSPZR’s 

DIN rail mounting saves time and panel space and snaps easily onto standard 

top hat (T) profile DIN rail.

SOFTWARE

The DSPZR is programmed with Crimson 3.0 software for Windows

®

 XP 

Service Pack 2 or later platforms. The software is an easy to use, graphical 

interface which allows the configuration of communications, logging, and 

stunning visual displays through simple drag and drop steps.

CONTENTS OF PACKAGE

- Data Station

- Terminal Block for connecting power

CompactFlash is a registered trademark of CompactFlash Association.

MODEL DSPZR – DATA STATION PLUS

Bulletin No.  DSPZR-D
Drawing No.  LP0913
Released  04/15

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

3.35 (85.2)

5.21

(132.4)

4.18 (106.1)

STS

CF

ETHERNET

RS485

RS232

USB HOST

RS232/PG

DIMENSIONS  In inches (mm)

C

US LISTED

UL

R

IND. CONT. EQ.

34AD

FOR USE IN HAZARDOUS LOCATIONS: 

Class I, Division 2, Groups A, B, C, and D

C

US LISTED

UL

R

3PWL

PROGRAMMABLE 

CONTROLLERS

Summary of Contents for DSPZR

Page 1: ...any application The DSPZR can synchronize the log files with any FTP server and or Microsoft s SQL Server for further analysis The CompactFlash card allows data to be collected and stored for later r...

Page 2: ...tery Lithium Coin Cell Typical lifetime of 10 years at 25 C A Battery Low system variable is available so that the programmer can choose specific action s to occur when the battery voltage drops below...

Page 3: ...s in the same conduit or raceway with AC power lines conductors feeding motors solenoids SCR controls and heaters etc The cables should be run through metal conduit that is properly grounded This is e...

Page 4: ...5 RS232 120 240 VAC VAC NEUT CHASSIS GND VDC PWR OUT COM PWR OUT 24 USER POWER POWER STS CF ETHERNET RS485 RS232 USB HOST RS232 PG Use appropriate communications cable See Ordering Information for des...

Page 5: ...rimson literature for more information on the proper names and locations of the files CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types...

Page 6: ...s they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson User Manual USER COMMUNICATION PORTS T...

Page 7: ...NET00 XCGSM GSM Cellular option card for ProducTVity Station Modular Controller or Data Station Plus 2 XCGSM000 XCPB PROFIBUS option card for ProducTVity Station Modular Controller or Data Station Plu...

Page 8: ...Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any pe...

Reviews: