background image

June 2015

N-Tron

®

 Series

NT24k

TM

 Compact Industrial Managed Gigabit Ethernet Switches

Hardware Manual

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Summary of Contents for NT24k Series

Page 1: ...June 2015 N Tron Series NT24kTM Compact Industrial Managed Gigabit Ethernet Switches Hardware Manual Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 2: ...eries Hardware Manual Revised 06 02 2015 CHANGE HISTORY Revised Date Description February 2015 Initial Release June 2 2015 New models added Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 3: ...n the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard AVERTISSEMENT Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables L utilisation de matériel électrique dans un tel environnement constitue un danger certain WARNING Do not operate the equipment in a manner not specified by this manual AVERTISS...

Page 4: ...ANGEREUX This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only Combinations of equip ment in your system are subject to investigation by the local authority having jurisdiction at the time of installation Cet appareil est adapté pour utilisation en Classe I Division 2 Groupes A B C D ou endroits non dangereux seulement Combinaisons d équipement...

Page 5: ...e retired le panneau du châssis SURROUNDING AIR TEMPERATURE TEMPERATURE AMBIANTE NT24k models without PoE Power over Ethernet option 40 C to 85 C NT24k PoE models 40 C to 80 C Note Use 110 C or higher rated copper wire 0 22NM 2lb in tightening torque for field installed conductors Note Utilisez fil de cuivre classé 110 C ou plus 0 22Nm 2 pouces livres couple de serrage pour les connecteurs install...

Page 6: ...es de la classe A des appareils numériques conformément à la partie 15 des règles de la FCC Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle Cet équipement génère utilise et peut émettre de l énergie radiofréquence et si il n est pas installé et utilisé conformément aux instructions peut causer des interférences...

Page 7: ... 12FX4 POE 58 1 19 NT24k 12GX4 POE 61 1 20 NT24k 14FX6 POE 64 1 21 NT24k 14GX6 POE 67 1 22 NT24k 12SFP DM4 POE 70 1 23 LEDs 73 1 24 Transceiver Characteristics 75 1 25 Ordering Guide 76 Chapter 2 Hardware Installation 81 2 1 Unpacking 81 2 2 Mounting the NT24k Unit 81 2 3 Power Source 83 2 4 Grounding the Unit 87 2 5 Configurable Alarm Contact 88 2 6 Connecting the Unit 88 2 7 Ethernet Cable 89 2 ...

Page 8: ...ct models are available with copper only ports or a mix of copper and fiber ports IEEE 802 3af at PoE models are also available Performance NT24k managed switches provide uncompromising performance in harsh environments including network features like N Ring VLAN Quality of Service QoS port mirroring IGMP SNTP and SNMP Additionally the NT24k offers IEEE 802 1x with RADIUS remote server authenticat...

Page 9: ... DIN Rail 40 C to 85 C 8 4 NT24k 12GX4 12 DIN Rail 40 C to 85 C 8 4 NT24k 14FX6 14 DIN Rail 40 C to 85 C 8 6 NT24k 14GX6 14 DIN Rail 40 C to 85 C 8 6 NT24k 12SFP DM4 12 DIN Rail 40 C to 85 C 8 Up to 4 NT24k 8TX POE 8 DIN Rail 40 C to 80 C 8 8 PoE NT24k 10FX2 POE 10 DIN Rail 40 C to 80 C 8 8 PoE 2 NT24k 10GX2 POE 10 DIN Rail 40 C to 80 C 8 8 PoE 2 NT24k 11FX3 POE 11 DIN Rail 40 C to 80 C 8 8 PoE 3 ...

Page 10: ...ransitions to Gigabit network requirements Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring configuration Backup and...

Page 11: ...ure 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 2 22 5 64 cm Depth 5 54 14 07 cm Weight 1 68 lbs 0 76 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Front 2 5 08 cm Top 4 10 16...

Page 12: ...ware Manual Revised 06 02 2015 12 NT24k 8TX 1 2 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 13: ...tions to Gigabit network requirements Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring configuration Backup and rest...

Page 14: ...re 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 1 97 lbs 0 89 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Front 2 5 08 cm Top 4 10 16 ...

Page 15: ...are Manual Revised 06 02 2015 15 NT24k 16TX 1 3 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 16: ...00Base T X copper ports Two 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring configuration Bac...

Page 17: ...ENTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 1 95 lbs 0 89 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fro...

Page 18: ...are Manual Revised 06 02 2015 18 NT24k 10FX2 1 4 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 19: ...t 10 100 1000Base T X copper ports Two 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring confi...

Page 20: ...TAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 1 95 lbs 0 89 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Front...

Page 21: ...are Manual Revised 06 02 2015 21 NT24k 10GX2 1 5 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 22: ...t 10 100 1000Base T X copper ports Three 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring conf...

Page 23: ...MENTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 1 96 lbs 0 89 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fr...

Page 24: ...are Manual Revised 06 02 2015 24 NT24k 11FX3 1 6 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 25: ...t 10 100 1000Base T X copper ports Three 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring con...

Page 26: ...NTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 1 96 lbs 0 89 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fron...

Page 27: ...are Manual Revised 06 02 2015 27 NT24k 11GX3 1 7 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 28: ...ight 10 100 1000Base T X copper ports Four 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring co...

Page 29: ...ENTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 2 05 lbs 0 93 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fro...

Page 30: ...are Manual Revised 06 02 2015 30 NT24k 12FX4 1 8 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 31: ...t 10 100 1000Base T X copper ports Four 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring conf...

Page 32: ...NTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 2 05 lbs 0 93 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fron...

Page 33: ...are Manual Revised 06 02 2015 33 NT24k 12GX4 1 9 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 34: ...ht 10 100 1000Base T X copper ports Six 100BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring confi...

Page 35: ...ENTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 2 06 lbs 0 94 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fro...

Page 36: ...re Manual Revised 06 02 2015 36 NT24k 14FX6 1 10 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 37: ...ht 10 100 1000Base T X copper ports Six 1000BaseFX fiber ports Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring conf...

Page 38: ...NTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 2 06 lbs 0 94 kg Mount 35 mm DIN Rail RECOMMENDED WIRING CLEARANCE Fron...

Page 39: ...re Manual Revised 06 02 2015 39 NT24k 14GX6 1 11 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 40: ...rts Eight 10 100 1000Base T X copper ports Four SFP ports 100Base and 1000Base transceivers sold separately Redundant 10 to 49 VDC Power Inputs Keeps network running in the event of a power supply failure Extended Environmental Specifications 40 C to 85 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port...

Page 41: ... separately ENVIRONMENTAL Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 3 10 7 87 cm Depth 5 54 14 07 cm Weight 1 91 lbs 0 87 kg Mount 35 mm DIN Rail RECOMMENDED ...

Page 42: ... Manual Revised 06 02 2015 42 NT24k 12SFP DM4 1 12 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 43: ...equirements Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto conf...

Page 44: ...NNECTORS 10 100 1000BaseT Eight RJ45 copper ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07 cm Weight 3 13 lbs 1 ...

Page 45: ...e Manual Revised 06 02 2015 45 NT24k 8TX POE 1 13 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 46: ...unning in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A B C and D Plug and Play Operation IGMP auto configuration Automatic port detection and setup Simple network ring configuration Backup and restore via N...

Page 47: ...BaseT Eight RJ45 Copper ports 100BaseFX Two SC or ST duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07...

Page 48: ... Manual Revised 06 02 2015 48 NT24k 10FX2 POE 1 14 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 49: ...ach port Two 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A ...

Page 50: ...000BaseT Eight RJ45 copper ports 1000BaseFX Two SC duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07 c...

Page 51: ... Manual Revised 06 02 2015 51 NT24k 10GX2 POE 1 15 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 52: ...h port Three 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE outputs on all RJ45 ports simultane ously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Group...

Page 53: ...BaseT Eight RJ45 copper ports 100BaseFX Three SC or ST duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92cm Width 4 28 10 88 cm Depth 5 54 14 0...

Page 54: ... Manual Revised 06 02 2015 54 NT24k 11FX3 POE 1 16 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 55: ...ach port Three 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups ...

Page 56: ...00BaseT Eight RJ45 copper ports 1000BaseFX Three SC duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07 ...

Page 57: ... Manual Revised 06 02 2015 57 NT24k 11GX3 POE 1 17 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 58: ...ch port Four 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups ...

Page 59: ...BaseT Eight RJ45 copper ports 100BaseFX Four SC or ST duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 0...

Page 60: ... Manual Revised 06 02 2015 60 NT24k 12FX4 POE 1 18 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 61: ...ach port Four 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A...

Page 62: ...00BaseT Eight RJ45 copper ports 1000BaseFX Four SC duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07 c...

Page 63: ... Manual Revised 06 02 2015 63 NT24k 12GX4 POE 1 19 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 64: ...ch port Six 100BaseFX fiber ports with SC ST connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A...

Page 65: ...BaseT Eight RJ45 copper ports 100BaseFX Six SC or ST duplex fiber ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07...

Page 66: ... Manual Revised 06 02 2015 66 NT24k 14FX6 POE 1 20 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 67: ...ach port Six 1000BaseFX fiber ports with SC connectors Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A ...

Page 68: ...0 1000BaseT Eight RJ45 Copper ports 1000BaseFX Six SC Duplex ports ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28 10 88 cm Depth 5 54 14 07 cm W...

Page 69: ... Manual Revised 06 02 2015 69 NT24k 14GX6 POE 1 21 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 70: ...orts 100Base and 1000Base transceivers sold separately Redundant 22 to 49 VDC Power Inputs Boosts power to meet PoE output requirements Keeps network running in the event of a power supply failure IEEE 802 3af at PoE Output Supports PoE output on all RJ45 ports simultaneously Extended Environmental Specifications 40 C to 80 C operating temperature range 2M hours MTBF UL cUL Class I Div 2 Groups A ...

Page 71: ...rts 100 1000Base SX LX SFP Port Up to four SFP port transceivers SFP transceivers sold separately ENVIRONMENTAL Operating Temperature 40 C to 80 C Storage Temperature 40 C to 80 C Operating Humidity 10 to 95 non condensing Operating Altitude 0 to 10 000 ft Shock 200 g 10 ms bulkhead mounted Vibration 50 g 5 200 Hz Triaxial bulkhead mounted MECHANICAL Case Dimensions Height 5 88 14 92 cm Width 4 28...

Page 72: ...anual Revised 06 02 2015 72 NT24k 12SFP DM4 POE 1 22 3 Dimensions All specifications are subject to change Consult the company website for more information Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 73: ...n Green Power is On Red Power is On and a fault condition exists Off Power is Off LNK Green 10 100 1000 Mb Link between ports Off No link between ports ACT Green Data is active between ports Activity light blink rate indicates activity not necessarily the volume of activity Off Data is inactive between ports PoE Port Status Green Port is supplying PoE power normally Blinking Port has not completed...

Page 74: ... The switch is operating normally Flashing Green The switch has not been configured Flashing Red A recoverable minor fault has occurred Steady Red A non recoverable major fault has occurred Network Status Indicator State Description Steady Off The switch is not powered up or an IP address has not been configured Flashing Green An IP address is configured but no connections have been established St...

Page 75: ...m 20 dBm 23 dBm 24 dBm Wavelength 850 nm 1310 nm 1310 nm 1550 nm Assumed Fiber Loss 3 5 to 3 75 dB km 0 40 dB km 0 40 dB km 0 25 dB km Laser Type VCSEL FP DFB DFB Fiber Length 2 km 10 km 40 km 80 km TX Power Min 19 dBm 15 dBm 5 dBm 5 dBm RX Sensitivity Max 31 dBm 34 dBm 34 dBm 34 dBm Wavelength 1310 nm 1310 nm 1310 nm 1550 nm Assumed Fiber Loss 3 5 to 3 75 dB km 0 40 dB km 0 40 dB km 0 25 dB km La...

Page 76: ...ber Description NT24k 8TX POE Eight Port 10 100 1000Base T X Managed PoE Industrial Ethernet Switch NT24k NM PMK NT24k Non Modular Panel Mount Kit NTCD CFG NT24k Configuration Recovery Device NTPS 24 20 DIN Rail Power Supply 20 Amp 24 VDC NTPS 48 10 DIN Rail Power Supply 10 Amp 48 VDC Part Number Description NT24k 16TX 16 Port 10 100 1000Base T X Managed Industrial Ethernet Switch NT24k NM PMK NT2...

Page 77: ...ged Industrial Ethernet Switch 8 10 100 1000BaseT 3 100BaseFX singlemode ports NT24k 12FX4 XX 12 Port Gigabit Managed Industrial Ethernet Switch 8 10 100 1000BaseT 4 100BaseFX multimode 2km ports NT24k 12FXE4 XX YY 12 Port Gigabit Managed Industrial Ethernet Switch 8 10 100 1000BaseT 4 100BaseFX singlemode ports NT24k 14FX6 XX 14 Port Gigabit Managed Industrial Ethernet Switch 8 10 100 1000BaseT 6...

Page 78: ... Ethernet Switch 8 10 100 1000BaseT 6 1000BaseSX multimode 550m ports NT24k 14GXE6 SC ZZ 14 Port Gigabit Managed Industrial Ethernet Switch 8 10 100 1000BaseT 6 1000BaseLX singlemode ports NTCD CFG NT24k Configuration Recovery Device NTPS 24 1 3 DIN Rail Power Supply 1 3 Amp 24 VDC NT24k NM PMK NT24k Non Modular Panel Mount Kit Part Number Description N24k 12SFP DM4 12 Port Gigabit Managed Industr...

Page 79: ...net Switch 8 10 100 1000BaseT 3 100BaseFX singlemode ports NT24k 12FX4 XX POE 12 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 4 100BaseFX multimode 2km ports NT24k 12FXE4 XX YY POE 12 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 4 100BaseFX singlemode ports NT24k 14FX6 XX POE 14 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000Bas...

Page 80: ...seSX multimode 550m ports NT24k 14GXE6 SC ZZ POE 14 Port Gigabit Managed PoE Industrial Ethernet Switch 8 10 100 1000BaseT 6 1000BaseLX singlemode ports NTCD CFG NT24k Configuration Recovery Device NTPS 24 20 DIN Rail Power Supply 20 Amp 24 VDC NTPS 48 10 DIN Rail Power Supply 10 Amp 48 VDC NT24k NM PMK NT24k Non Modular Panel Mount Kit Part Number Description NT24k 12SFP DM4 POE 12 Port Gigabit M...

Page 81: ...nel or other flat surface A clearance of one inch should be observed on the sides back top and bottom to allow proper ventilation Also a cable bend radius of two inches should be observed for the front and top side of the unit DIN Rail Mounting Instructions Install the switch to standard 35mm DIN Rail as shown in the diagram above 1 First hook the top of the DIN Rail clip on the back of the switch...

Page 82: ...ires 3 Disconnect any communications cables from the unit 4 Insert a standard flat slotted screwdriver into the slot provided on the DIN Rail clip 5 Using the base of the switch as a pivot point apply upward force on the screwdriver to release the DIN Rail clip 6 With the DIN Rail clip latching mechanism released continue to rotate the switch upward and away from the panel 7 Once the switch has be...

Page 83: ...he DC voltage input plug from the power input header Install the DC power cables into the plug observing polarity Plug the voltage input plug back into the power input header Tightening torque for the terminal block power plug is 0 5 Nm 0 368 lb ft Verify that the power LED is on Note When a DC power supply is installed only one power supply must be connected to power for minimal operation For red...

Page 84: ...3af and or IEEE 802 3at for it to negotiate properly Devices with invalid PD signatures or non PoE devices will not be powered ON PoE capable models will remove power from the Powered Device if any of the following conditions occur Minimum power requirements are not satisfied The PD must draw minimum required current set forth by 802 3af at specifications in order to be powered on Maximum power is...

Page 85: ...e positive negative wires into the V2 V2 circular openings on the power connector by firmly pushing them into the terminal block Use 12 14 gauge solid or stranded wire to connect the Chassis Grounding point located near the power input ter minal to a known good ground Verify that no exposed conductors are touching each other or the unit case before powering on the unit Apply power to the unit and ...

Page 86: ...the positive negative wires from the V2 V2 circular openings on the power connector General Power Supply Notes for NT24k PoE models NT24k PoE models use 12 14 gauge solid or stranded wire with ferrules Voltage drop across the power wires between the source power supply and the NT24k unit should be considered during installation 0 5V 10ft for 12 AWG wire 0 65V 10ft for 14AWG Failure to use proper w...

Page 87: ...um voltage threshold 2 4 Grounding the Unit The grounding of any control system is an integral part of the design The optimum noise immunity and emissions are obtained when the NT24k chassis is connected to earth ground via a 12 14 gauge wire for the POE models and 14 18 gauge drain wire for all other units The NT24k units provide a ground lug see illustration that is used to provide a safe ground...

Page 88: ...other device use a standard CAT5E straight through or crossover cable with a minimum length of one meter and a maximum length of 100 meters Red Lion recommends the use of pre manufactured CAT5E cables to ensure the best performance If this is not an option and users must terminate their own ends on the CAT5E cables one of the two color coded standards shown to the right should be utilized If a use...

Page 89: ...g shielded cables it is generally recommended to only connect the shield at one end to prevent ground loops and interference with low level signals i e thermocouples RTD etc CAT5e cables manufactured to EIA 568A or 568B specifications are required for use with Red Lion Series switches In the event all CAT5e patch cables are short i e All Ethernet devices are located in the same local cabinet and o...

Page 90: ...SB interface accessed via the USB connector labeled as USB on the top of the compact models The USB connection is used to access the Command Line Interpreter CLI or PPP Point to Point Protocol USB Cable Connect the USB port of your PC and the Switch using a standard USB cable A cable with a Type A connector for the PC end and a Type B connector for the switch end must be used Standard USB cables a...

Page 91: ...uld result in an explo sion La connection USB est pour la connexion temporaire seulement Ne pas utiliser connecter ou déconnecter sauf si la zone est connue pour être non dangereuse Connexion ou la déconnexion dans une atmosphère explosive pourrait entraîner une explosion 2 10 Cleaning Clean only with a damp cloth Excess moisture or harsh chemicals can cause damage to the unit Port Settings 115200...

Page 92: ...201 The following login screen will appear For the User Name enter admin all lowercase For the password enter admin all lowercase Note For security purposes it is recommended that the password be changed according to your internal policies Login credentials can be changed in the User Management menu Upon successfully logging in the following screen will appear Please consult the NT24k Software Man...

Page 93: ...nty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Repairs are completed as soon as possible If you need a quicker turnaround ship the unit to us by air freight We give priority service ...

Page 94: ...XCLUSIVE IF AN RED LION PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT RED LION S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION...

Page 95: ...entioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice Red Lion makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall Red Lion be liable for any incidental special indirect or consequentia...

Reviews: