  FOUR MULTI-RANGE UNITS COVER:

 199.9 

A to 1.999 A *, 199.9 mV (AC or DC)

  1.999 V to 300 V (AC or DC)

  3 1/2-DIGIT, 0.56" (14.2 mm) HIGH RED LED DISPLAY W/POLARITY

  BUILT-IN SCALING PROVISIONS

  SELECTABLE DECIMAL POINT LOCATION

  AUTO ZEROING CIRCUITS

  OVER-RANGE INDICATION

  NEMA 4X/IP65 SEALED FRONT BEZEL

  OPTIONAL CUSTOM UNITS OVERLAY W/BACKLIGHT

*

  Accessory Shunts Available For Higher Current Ranges.

GENERAL DESCRIPTION

PAX Lite Current and Volt Meters are premium quality instruments designed 

for tough industrial applications. With multi-range capability, built-in provision 
for scaling, and DIP switch selectable decimal points, these meters offer the 
ultimate in application flexibility. Four models cover your voltage and current 
indicator needs. The meter can provide direct readout from pressure, speed or 
flow transducers, or any other variable that can be translated to voltage or 
current. The built-in scaling allows the display to be scaled to the desired 
engineering unit.

The 3 ½ -digit bi-polar display (minus sign displayed when current or voltage 

is negative) features a 0.56" high, 7-segment LEDs for easy reading. The meter 
is also available with custom units label capability. Using the PAX label kit 
(PAXLBK30), the selected label is installed behind the panel, keeping it safe 
from washdown or other environmental conditions. A DIP switch is used to 
control the backlight for the units label. 

The meters have a NEMA 4X/IP65 sealed bezel and extensive testing of 

noise effects to CE requirements, allowing the meter to provide a tough yet 
reliable application solution. 

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

literature or on equipment must be observed to ensure personal safety and to 
prevent damage to either the instrument or equipment connected to it. If 
equipment is used in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired.

DEFINITION OF TERMS

INSTALLATION CATEGORY

 (overvoltage category) 

I

, (CAT I):

Signal level, special equipment or parts of equipment, telecommunication, 
electronic, etc. with smaller transient overvoltages than Installation 
Category (overvoltage category) II. (See IEC 664 & IEC 61010)

INSTALLATION CATEGORY

 (overvoltage category) 

II

, (CAT II):

Local level, appliances, portable equipment, etc. with smaller transient 
overvoltages than Installation Category (overvoltage category) III. (See 
IEC 664 & IEC 61010)

MODEL PAXLI - PAX LITE CURRENT METERS &
MODEL PAXLV - PAX LITE VOLTMETERS

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for    mounting clip installation is 

2.1" (53.4) H x 5.0" (127) W.

Bulletin No.  PAXLI/V-E
Drawing No.  LP0566
Released  10/10

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: Risk of electric shock.

CC

US LISTED

US LISTED

UL

R

51EB

IND. CONT. EQ.

Summary of Contents for PAXLI

Page 1: ...vironmental conditions A DIP switch is used to control the backlight for the units label The meters have a NEMA 4X IP65 sealed bezel and extensive testing of noise effects to CE requirements allowing the meter to provide a tough yet reliable application solution SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the literature or on equipment must be observed...

Page 2: ... the Meter 6 Troubleshooting 7 Calibration 7 TABLE OF CONTENTS ORDERING INFORMATION PAXL 0 I Current Input V Voltage Input 0 A AC Input D DC Input Meter Part Numbers Accessories Part Numbers APSCM100 APSCM010 PAXLBK30 100 Amp DC Current Shunt 10 Amp DC Current Shunt Units Label Kit Accessory APSCM PAXLBK Accessories TYPE PART NUMBERS DESCRIPTION MODEL NO ...

Page 3: ...ARTH 350 volt peak 16 CERTIFICATIONS AND COMPLIANCES SAFETY UL Recognized Component File E179259 UL61010A 1 CSA C22 2 No 61010 1 Recognized to U S and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc UL Listed File E137808 UL508 CSA C22 2 No 14 M95 LISTED by Und Lab Inc to U S and Canadian safety standards Type 4X Enclosure rating Face only UL50 IECEE ...

Page 4: ...230 115 REAR TERMINALS FRONT DISPLAY 4 2 0 SETTING THE JUMPERS AND SWITCHES SWITCH FUNCTION 1 Decimal Point 1 000 0 2 Decimal Point 2 00 00 3 Decimal Point 3 0 000 4 Backlight Annunciator for Units Label 5 Enables the Scaling Pot 1 0 INSTALLING THE METER Installation The PAX meets NEMA 4X IP65 requirements when properly installed The unit is intended to be mounted into an enclosed panel Prepare th...

Page 5: ... enclosure which is properly connected to protective earth 2 Never run Signal or Control cables in the same conduit or raceway with AC power lines conductors feeding motors solenoids SCR controls and heaters etc The cables should be run in metal conduit that is properly grounded This is especially useful in applications where cable runs are long and portable two way radios are used in close proxim...

Page 6: ...y zero voltage can display a value of zero DIVISION FACTOR FORMULA VT x D D P D F D R WHERE VT Maximum Transducer Output D D P Display Decimal Point D F Division Factor D R Desired Reading D D P 0 000 1 The Display Decimal Point 00 00 10 D D P is determined by 000 0 100 the desired decimal point 0000 1000 placement in the readout After the Division Factor for the application has been calculated th...

Page 7: ...Scaling to obtain a numerical readout higher than the normal value of the current can also be accomplished in most cases by selecting a lower current range However the maximum current for the range must not be exceeded See Specifications for maximum input currents PROCESS CIRCUITRY VDC S3 S2 S1 S4 COMMON SIGNAL 0 199 9mA 0 19 99mA 1 Ω 9 Ω S5 0 1 999mA 0 199 9µA 90 Ω 900 Ω POT SCALE 1 Ω 0 1 999A 1 ...

Page 8: ...uyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those ex...

Reviews: