SmokeSight SS10MANN V0.6 

Page 1 

 

 

SmokeSight Residential Smoke Alarm 

By Redbusbar 

 
Part Number:  SS10MANN 
Description: 

240 VAC Mains Power Photoelectric Smoke Alarm with 2xAA 1.5VDC Battery Backup 

 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE OCCUPANT, TO BE RETAINED FOR THE LIFE OF THE ALARM. 

THIS SMOKE ALARM MUST BE INSTALLED BY A LICENSED ELECTRICIAN. 

1

 

Read all Instructions before Installation and Operation 

Regular testing of this smoke alarm is necessary to ensure the unit is functional and that the battery is in good 
condition. It is recommended that the smoke alarm be replaced after 10 years of normal service. The only user-
serviceable parts are the replaceable backup batteries. Refer to ‘Replacing the Backup Batteries’.  
 

 

 

 

RISK OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH 
• This product must only be installed and serviced by 
appropriately qualified and/or licenced electrical 
personnel. 
• This product must only be used for the purpose 
described in these instructions and must be installed in 
accordance with the local regulations. 
• Hazardous voltages may be present at wires 
connected to this product. 
• Before working on this product, isolate the electrical 
supply. 
• Ensure that the product has been correctly installed 
and tested for safe operation before reconnecting the 
electrical supply. 

Failure to comply with these instructions may result in 
death or serious injury. 

 

EQUIPMENT INSTALLATION HAZARD 
• This alarm cannot be operated from power derived 
from a square wave, modified square wave or modified 
sine wave inverter. These inverters are sometimes 
used in off grid installations such as solar or wind 
power sources. They produce high peak voltages that 
will damage the alarm. 
• Ensure that the mains supply, active and neutral is 
wired to the correct terminals. 
• Ensure that green LED is ON when mains supply is on. 
• Ensure that red LED is not fast flashing. 
• Smoke Test each interlinked alarm. Check to ensure 
every interlinked alarm, alarms correctly. If any unit 
fails to alarm, check all wiring and connections. 

Failure to follow these instructions may result in 
equipment damage or injury. 

 

Smoke Alarm – Top View 

 

Smoke Alarm – Bottom View 

 

1.

 

Mains (Green) LED 

2.

 

Alarm (Red) LED 

3.

 

Smoke Alarm Backup 
Battery Holder 

 

 

 

 

Summary of Contents for SmokeSight

Page 1: ...with the local regulations Hazardous voltages may be present at wires connected to this product Before working on this product isolate the electrical supply Ensure that the product has been correctly...

Page 2: ...AS NZS 60065 AS NZS 60950 1 IEC 62599 2 Sensing Type Photoelectric The smoke alarm contains NO radioactive material 3 Locations This smoke alarm can be used in all residential homes and apartments and...

Page 3: ...e above 95 or fall below 5 relative humidity False alarms and unstable operation may result In areas where particles of combustion are normally present such as garages or kitchens as this can cause fa...

Page 4: ...tion 1 If tamper prevention is required prevents alarm removal without the use of a tool remove the Tamper Clip from the mounting base by twisting it back and forth until it breaks loose 2 Strip the A...

Page 5: ...led correctly the smoke alarm is operational If smoke is detected the alarm will sound and the red LED will flash rapidly This will continue until the air is cleared of smoke During normal operations...

Page 6: ...Test button If cooking or other non hazardous sources cause the alarm to sound it can be temporarily silenced by pressing the Test Hush button The alarm then enters a low sensitivity period for 9mins...

Page 7: ...problem persists contact an electrician for replacement CHIRP One audible chirp every 40 to 50secs no LED flash Low battery warning Replace the 2xAA 1 5VDC batteries Press the Test Hush button to sile...

Page 8: ...ng the smoke alarm has not cannot be cleaned properly b If the alarm does not sound reinstall the cleaned smoke alarm ALWAYS TEST THE SMOKE ALARM AFTER CLEANING If the smoke alarm is defective in any...

Reviews: