THE

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

BOILING WATER DISPENSER

INSTALLATION & OPERATING

INSTRUCTIONS

Summary of Contents for SB2

Page 1: ...THE IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER BOILING WATER DISPENSER INSTALLATION OPERATING INSTRUCTIONS ...

Page 2: ...sed by a qualified electrician and plumbing engineer Installation and wiring must conform to current IEE Regulations U K and the Water Regulations Act 1999 Local regulations may apply in other countries The steam vent connection MUST BE MADE as required in these instructions The product must be supplied by a 13 Amp fused double pole isolating switch with a minimum contact gap of 3mm in each pole C...

Page 3: ...ssure range between 0 7 Bar 69kPa 10psi and 10 0 Bar 940kPa 140psi Do not connect to a storage tank Isolate the water supply Lay in 15mm water supply pipe to the location of the inlet connection Fig 1 Check that the water supply position gives enough space under the unit for it to be used properly Flush through the water supply before making the final connection so that any debris is removed Note ...

Page 4: ...tact gap of 3mm in each pole adjacent to where the unit will be fixed Removing the front cover Remove the screws from the bottom and top edge of the unit Fig 3 Support the front cover and remove the flow knob Fig 4 Pull the front cover away from the unit Please note that there is a flying lead and plug freely attached to the front cover Fig 3 ...

Page 5: ...5 Fig 5b Fig 4 Fig 5a ...

Page 6: ...e core multi strand PVC insulated mains cable The terminal block will not accept cable diameters above 1 5mm2 Check that the mains supply matches the electrical rating on the product The rating plate is located on the bottom edge of the unit IMPORTANT Connect the supply cable complying with BS6500 to this appliance in accordance with the following code GREEN AND YELLOW EARTH connect to terminal ma...

Page 7: ...front cover knob clockwise How to operate the SB2 Make sure the electricity and water is turned on Refer to Fig 6 Use the POWER button to switch the SB2 on and to power down The SB2 should be switched off at the mains if the water is not required e g at weekends holidays etc POWER light When the SB2 is on the POWER light will come on FULL light The FULL light comes on when the tank is full of wate...

Page 8: ...the SB2 Place your cup under the red spout at the bottom of the unit Turn the knob clockwise to fill your cup Fig 7b Turn the knob anti clockwise to OFF Fig 7a WARNING SCALDING HOT WATER can be dispensed from the SB2 Never wash your hands directly from the unit Some plastic cups can distort if they are filled with boiling water so causing a danger of scalding How to clean and descale your SB2 Befo...

Page 9: ... is used f All the lights are out and the POWER button does not work Ensure that the electricity supply is switched on at the isolator then press the POWER button g The water flowing from the outlet is sometimes only a trickle The water in the tank has been drained out due to a high demand Wait for the FULL TEMPERATURE READY lights to come on again h The SB2 takes a long time to reach the selected...

Page 10: ...lows continuously from the steam vent pipe Check that the float switch operates correctly and switches the water solenoid on and off d The water tank takes more than 20 minutes to fill with water CONDITION SB2 is switched on at the local isolator and the unit is empty of water POWER button is pressed SB2 is switched on at the local isolator and the unit is already full of cold water POWER button i...

Page 11: ...SB2 and have a note of the Catalogue number as stated on the rating plate along the bottom edge of the unit SPARE PARTS Part No Part Description 95719601 95719613 95719614 95719615 95719616 95719617 95719618 95719608 95719609 95719619 95719611 95719620 Element assembly Terminal block Logic board assembly Power PCB assembly Solenoid valve Float switch Cable pack Control knob Outlet Spout Scale Trap...

Page 12: ...not been taken apart modified or repaired except by a person authorised by us d EVIDENCE of the date of purchase in the form of an invoice receipt or hire purchase document is included with the appliance if returned under guarantee SCALE PREVENTION Formation of scale occurs with hot water heaters operating at high temperatures in hard water areas We strongly recommend the use of in line resin filt...