background image

HIDEAWAY

ACTIVE SENSOR-FLUSH URINAL

To see the complete HIDEAWAY range go to  

www.reece.com.au/bathrooms

Disclaimer:

 Products in this specification manual must by regulation be installed by licensed and registered 

trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from 
their range without prior notification. Dimensions are nominal measurements only.  Dimensions and set-outs 
listed are correct at time of publication however the manufacturer/distributor takes no responsibility for 
printing errors.  

Tech Page Version 4

SPECIFICATIONS

Recommended Use

Domestic, hotel and commercial

Urinal

Vitreous China American Standard Active Urinal

Colour 

White

Water Inlet 

Concealed rear inlet DN20 and kee seal

Outlet

Plastic Trap is supplied with kee seal for push-in 

connection to DN50 waste pipe

Application

Inwall, suitable for minimum cavity wall thickness 

of 90mm, Induct, Ceiling 

Flush Pipe Height

Maximum 2000mm from urinal inlet
Minimum 500mm from urinal inlet

Urinal Fixing

L shape brackets supplied

Template

Included in packaging

Water Saving

WELS 6 star rating (0.8L/flush)

Sensor models 

240V AC (transformer) or 6 V DC (battery pack)

Easy to Adjust

Push button flush volume adjustment based on 

the dynamic supply pressure

Easy to Install

Supplied complete with all mounting hardware 

and cables

Sensor Technology

Prevents false detection

Normal Mode

In Normal mode the unit will flush after every use

Eco Mode Setting

Additional water conservation for high traffic 

bathrooms. A flush is only activated after the 

third user has visited or 15 minutes has elapsed, 

whichever comes first.

Saver Mode 

When high frequency usage is detected in 

Normal mode, the unit will switch to Saver mode 

to conserve water.

Hygienic

Urinal automatically flushes touch free after use.

Janitors Flush

Triggers and automatic hygiene flush after 48 

hours of non-use.

Over-flow Protection

Sensor can detect blockages and will stop 

flushing to prevent urinal overflow

Fault finding 

Self diagnostic fault finding

Technical Support

If you have any questions or queries during 

installation please contact Tech-Support for 

phone assistance free call 07 3875 2465  We are 

happy to assist you.

Dear Customer,

This is the warranty by Reece Pty. Ltd. relating to this product. 
Please keep it together with your purchase receipt. In the unlikely event of 
a query please contact your nearest Reece Plumbing Centre.

Warranty

You have purchased a quality product from Reece Australia. This 
product is covered by a twelve month warranty.  This warranty 
covers faults in the product construction, material and assembly. Faulty 
products will be repaired or exchanged free of charge. Faulty items be-
come our property.
This warranty does not include faults caused by:
• Unsuitable or improper use
• Incorrect installation 
• Installation or part installation by the purchaser or any person other    

than a LICENSED PLUMBER or tradesman

• Normal wear and tear
• Inadequate or complete lack of maintenance

Cleaning Recommendations
Any sanitaryware should not be cleaned with abrasive materials 
eg. steel wool/scourers. Do not use any corrosive or abrasive cleaning 
agents containing acids or scouring agents. 
In the event of a warranty claim, we will replace or repair defective prod-
ucts, or pay for the cost of having defective products repaire

or replaced, but will not be liable for any injury to any person, damage to 
any property, any indirect or consequential loss, or in any other respect.

WARRANTY & CARE DETAILS 

571

Φ

10

269

279

350

33

299

Disclaimer:

Products in this speci cation manual must by regulation be installed by licensed and registered trade people. The manufacturer/dis-

tributor reserves the right to vary speci cations or delete models from their range without prior noti cation. Dimensions and set-outs 

listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Tech Page Version 1

WMK

T21654.4

   

 

Watermark

WMKT21654.4

Fixing

To wall with L shape bracket supplied

Standards

AS/NZS 6400:2005

Warranty

12 months warranty (see below)

Template

Including in packaging

 

WELS

3 Star rating, average  ush 1.2 litres  

expansions coupling 

page 1 of 16

The more 

stars the more 

water efficient

WATER RATING

www.waterrating.gov.au

In accordance with AS/NZS 6400

Licence No. 0025

Reece Limited

0.8

litres per 

flush per stall

Summary of Contents for HIDEAWAY

Page 1: ...ions or queries during installation please contact Tech Support for phone assistance free call 07 3875 2465 We are happy to assist you Dear Customer This is the warranty by Reece Pty Ltd relating to t...

Page 2: ...d valve is fitted with 200mm cable and 2 pin connector Fig 1 Cables are supplied as follows Sensor extension cable 2500mm long with female male 4 pin connectors 1800mm power cable wired with single ma...

Page 3: ...mum size not supplied free of kinks for sensor extension cable Fig 4 7 Fit single 240 volt 10 amp GPO for transformer power supply unit adjacent to proposed location of controller 3 0 Control Unit Con...

Page 4: ...V flush with finished wall Fig 7 5 Fit kee seal to waste trap and lubricate before gently pushing into 50mm PVC DWV pipe so trap finishes flush with face of wall Fix waste trap to wall with single scr...

Page 5: ...r C Do not press buttons on the controller yet LED FLASH RESPONSE FIRST TIME POWER ON MEANING 1 Initial 2 short ashes followed by steady flashes at 1 second intervals After about 25 seconds of steady...

Page 6: ...ns in the male plug are not bent apart and line up with the holes in the female plug If required use your fingers to squeeze the plug and pins together 3 Check plug alignment and re connect Re connect...

Page 7: ...Schools This program will ush the urinal only after every 3 rd user or 15 minutes after use whichever comes rst It also triggers a janitor s ush after 48 hours of non use Button 2 To change the progr...

Page 8: ...onnection Now the ushing is suspended for 30 minutes 3 Add more of the cleaning agent to the water of the urinal After 30 minutes a ush will automatically trigger and the urinal is ready for use How t...

Page 9: ...instructions is left with the end user for future reference HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Use the following figures to provide installation guidance Fig 11 In ceiling ins...

Page 10: ...NSOR FLUSH URINAL Plumbers please ensure a copy of the installation instructions is left with the end user for future reference HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Continued Fig...

Page 11: ...HIDEAWAY ACTIVE SENSOR FLUSH URINAL HIDEAWAY ACTIVE SENSOR FLUSH URINAL 8 0 Installation Types Continued Fig 13 page 11 of 16...

Page 12: ...ically switch to Saver Mode 1 flush every minute when 4 users visit the urinal in less than 1 minute intervals no matter how many times used 1 minute of non use will reset the control unit back to Nor...

Page 13: ...sioning Look for 2 confirmation flushes to confirm urinal is functioning normally Problem fixed If problem cannot be resolved call 07 3875 2465 for assistance 5 seconds pause Pause then Temperature Se...

Page 14: ...ge is blocked Dynamic pressure has changed Un screw the solenoid cartridge and rinse out dirt out of the strainer see Section 1 Maintenance of the Solenoid Cartridge Check dynamic pressure and reset f...

Page 15: ...enoid cartridge lubricate the two O Rings with a suitable tap O Ring lubricant Hydroseal tap lubricant or equivalent Note Do not over tighten The max torque is 1Nm hand tight 13 0 Spare parts 9503303...

Page 16: ...RINAL INLET OUTLET SEAL 200 034 9503309 HIDEAWAY URINAL SOLENOID CARTRIDGE 200 036 9503310 HIDEAWAY URINAL SOLENOID BODY 200 037 9503311 HIDEAWAY URINAL AIR BREAK 200 038 9503312 HIDEAWAY URINAL FLUSH...

Reviews: