background image

IQ-LOGGER™

This easy-to-use core logging solution provides

fast, accurate structural measurements

Q U I C K R E F E R E N C E G U I D E

REFLEX IQ-LOGGER™ Software v1.2

Inside

1. Installation
2. Set Up
3. Initialisation
4. Logging
5. Verification

Compatible

The information contained in this document is believed to be accurate at the time of printing; however, Imdex Limited, its subsidiaries, agents, distributors or resellers assume no responsibility
or liability for the accuracy or completeness of, or consequences arising from, such information and the use of such information. Changes, typos, and technical inaccuracies will be corrected in
subsequent publications. This publication is subject to change without notice.

Determination of the suitability of any information or product for use contemplated by any user, and the manner of that use is the sole responsibility of the user.

Copyright © 2017 Imdex Limited.

Summary of Contents for IQ-LOGGER

Page 1: ...er Imdex Limited its subsidiaries agents distributors or resellers assume no responsibility or liability for the accuracy or completeness of or consequences arising from such information and the use o...

Page 2: ...device by squeezing both side buttons until the blue and green lights illuminate enable Bluetooth on the computer Launch REFLEX IQ LOGGER software Double click desktop icon to launch the REFLEX IQ LO...

Page 3: ...Add Drillhole in the app Configure Drillhole in the app Custom Structural Feature lists can be created in IMDEXHUB IQ and synced to the app using the Sync button IQ LOGGER S E T U P 3...

Page 4: ...then sit it on a flat surface until the red light extinguishes and the laser illuminates A flashing green light indicates that battery charge is less than 20 If the battery charge is 5 the device will...

Page 5: ...device downhole Roll the REFLEX IQ LOGGER device down the core along the orientation line check that the depth increases in the software interface Align with first structure Stop rolling the device wh...

Page 6: ...de the device back on the core with the front wheel alignment marker inline with the first structure then slide downhole to the next structure ensure it is aligned with the drillcore orientation line...

Page 7: ...e linear structure by aligning the laser with the line on the plane surface Press the front button on the top of the device twice quickly to set the QA Flag for that reading Take measurements for all...

Page 8: ...and select the new feature from the dropdown list note that you cannot change linear readings to planar and vice versa l If custom lists have been synced from IMDEXHUB IQ select additional meta data a...