background image

NK ZSU4   

 

 

  imported by goobay    / Pillmanstr. 12 / 38112 Braunschweig / WEEE 828 986 22 

 

          

OPERATING INSTRUCTIONS 

Please read the following instructions carefully before connecting this timer to electrical appliances. 

                                           IMPORTANT 
Don’t plug in an appliance where the load exceeds the maximum. Always ensure the plug of any appliance is 
fully inserted into the timer outlet. If cleaning of the timer is required, remove from main power and wipe timer 
with a dry cloth. 
DO NOT IMMERSE TIMER IN WATER OR ANY OTHER LIQUID. 
Heaters and similar appliances should never be left unattended during operation. The manufacturer 
recommends such appliances not to be connected to timers. 
                                     KEYBOARD DEFINITION 
a. 

MASTER CLEAR: Clear all data in memory including current time and all programs. 

b. 

RANDOM: Set or cancel random function   

c. 

CLOCK: Set current time combined with buttons WEEK, HOUR, MINUTE. Select 12 or 24 hour mode 
combined with button TIMER. Activate summertime function combined with button ON/AUTO/OFF. 

d. 

TIMER: Set programs combined with buttons WEEK, HOUR, MINUTE. Select 12 or 24 hour mode 
combined with button CLOCK. 

e. 

ON/AUTO/OFF: Select operating modes of timer. 

f. 

WEEK: Set week combined with button CLOCK or TIMER. 

g. 

HOUR: Set hour combined with button CLOCK or TIMER. 

h. 

MINUTE: Set minute combined with button CLOCK or TIMER. 

i. 

RST/RCL: Override programs or recall the overridden programs. 

j. 

LED: Shows status of power output. When the indicator is ON, there is power output. When the indicator is 
OFF, there is no power output. 

                                      GENERAL FEATURES 
1.    8 ON/OFF programs with 1 minute step 
2.    Output LED indicator. 
3.    MANUAL ON/AUTO/MANUAL OFF selectable 
4.    12/24 hour mode selectable 
5.    Summertime function available   
6.    Random function with a random advance of 0-30 minutes between 6:00PM and 6:00AM. 
7.    16 combinations of day or blocks of days available as follows: 

Mo 
Tu 
We 
Th   
Fr 
Sa 
Su 
Mo, Tu, We, Th, Fr, Sa, Su 
Mo, Tu, We, Th, Fr 
Sa, Su 
Mo, Tu, We, Th, Fr, Sa 
Mo, We, Fr 
Tu, Th, Sa 
Mo, Tu, We 
Th, Fr, Sa 
Mo, We, Fr, Sa 

                                      INITIAL OPERATION 
1. 

Plug the timer into a regular 230/240 Volts power outlet and turn the power on. Leave for approximately 12 
hours to charge the Memory Back-Up battery. 

2. 

Clear all current information by pressing MASTER CLEAR button with a sharp object such as a pen or 
pencil after charging. 

3. 

The timer is now ready to be set up for use. 

 

                                   SETTING CURRENT TIME 
1. 

Press CLOCK button and hold, simultaneously press WEEK button until the right day is displayed. 
Continue by pressing HOUR or MINUTE button until the current hour or minute is displayed. When 
setting, the buttons WEEK, HOUR or MINUTE can be held down for rapid forward counting. 

2. 

Release both buttons. The week and time will be set. 

3. 

To reset incorrect time, repeat above steps. 

                                      
                                     SETTING PROGRAMS 
 
TIP: When verifying your programs, ensure that the settings do not overlap, especially when using the block 
option. If there are program settings overlapping, the timer ON or OFF will be executed according to program 
time, not by program number. Program OFF has the priority over program ON. 
1. 

Press TIMER button and release. LCD shows ON_1. The first ON setting can be made now. 

2. 

Press WEEK button to set the day or block of days. Set the time by pressing HOUR and MINUTE button. 

3. 

Press TIMER button again to finish the first ON setting and enter into the first OFF setting .LCD shows 
OFF_1. By repeating 2 to make the first OFF setting. 

4. 

Press TIMER button again to finish the first OFF setting and enter into the 2

nd

 ON setting. Repeat 2 and 

3 to program remaining settings. Press TIMER button and hold for 2 seconds to enter fast advance. 

5. 

After completing settings, press CLOCK button. The timer is ready to operate. 

EXAMPLE: Timer ON at 17:15 and OFF at 22:30 everyday 
a.  Press TIMER once and release. LCD displays ON_1 
b.  Press WEEK till LCD displays

MO, TU, WE, TH, FR, SA, SU

 

c.    Press HOUR till LCD displays 5:00PM or 17:00 
d.    Press MINUTE till LCD displays 5:15PM or 17:15 
e.  Press TIMER again and release. LCD displays OFF_1 
f.      Repeat the above c. and d. till LCD displays 10:30PM or 22:30 

                      
                      MANUAL ON/AUTO/MANUAL OFF SETTING 

Operating modes can’t be changed during program settings. 
1.  Press ON/AUTO/OFF button to revert the three modes in turn. 
2.    The programs can only be executed in AUTO mode. When AUTO is selected, the timer operates as the 

programs. In MANUAL ON or MANUAL OFF mode all programs are ignored and the timer doesn’t 
operate. When MANUAL ON mode is selected, power output is always ON. When MANUAL OFF mode 
is selected, power output is permanently off. 

3.    When the mode is turned from MANUAL ON to AUTO, the timer will keep the setting of MANUAL ON until 

to the next timer setting. 

                             RANDOM FUNCTION 

1.    Press RANDOM button. LCD displays RANDOM. Random function is activated. 
2. 

When this function is ON, the settings will be executed with a random advance of 0-30 minutes between 
6:00PM and 6:00AM. 

3. 

Press the RANDOM button again to cancel this function. Random function can't be set during program 
settings. 

                              12/24 HOUR MODE 

Press CLOCK and TIMER simultaneously to turn the time display between 12 and 24 hour mode. 

                            SUMMERTIME FUNCTION 

1.  Press CLOCK and ON/AUTO/OFF simultaneously. LCD shows SUMMER. Clock advances 1 hour. 
2.    To revert to winter setting, press the two buttons again. Clock moves backward 1 hour. SUMMER 

disappears in LCD. 

                                SPECIFICATIONS 
Voltage                   230/240 V AC 50Hz 
Max Load                  16(2)A, 3600W 
Min Setting Time            1 Minute 
Operating temperature        -10 to +40

 

Accuracy                   +/- 1 minute per month   
Battery backup              Ni MH 1.2V

100HRs   

Model:                    NK ZSU 4   
 

Reviews: