background image

1

CN

  2011

INSTALLATION  INSTRUCTIONS  FOR 

MODELS  JR-3  &  JR-4

This package contains the following factory supplied parts:

QUICK  TOUCH  TIMER

CORD SET

TWO  STEAM NOZZLES &  ESCUTCHEONS

WATER INLET

JR-3 or JR-4 

QUICK TOUCH TIMER SWITCH

(Packaged inside electrical box)

 

Use only the Relax-A-Mist factory supplied parts in this package!

1. GENERAL INFORMATION

 (See “SELECTION” p.5).

STEAM      GENERATOR      LOCATION   

The  steam

generator should be located in a ventilated area outside
of,  but  within  20  feet  of  the  shower  or  steam  room,
where  the  steam  pipes  can  be  installed  without  the
possibility of a steam trap.  The steam generator may
be placed under the floor, in a closet or any convenient
location  where  it  WILL  BE  LEVEL,  DRY,  AND  WILL
NOT  FREEZE  in  the  winter.    The  steam  generator
MUST be easily accessible should service be required
in  the  future.    INSTALL  THE  STEAM  GENERATOR
WITH THE COPPER STEAM PIPES COMING OUT
OF  THE  TOP  OF  THE  APPLIANCE  AND  THE
ELECTRICAL BOX FACING THE ACCESS!  See 

Fig1

.

STEAM  PIPES AND STEAM NOZZLE

 (To and in the

Steam Room)  The steam pipes must be a minimum of
½  inch  I.D.  rigid  copper  pipe  between  the  steam
generator and the area to be steamed.  Installing the
steam  pipes  using  the  most  direct  or  shortest  route
(WITHOUT FORMING A STEAM TRAP) and with the
fewest number of elbows will, in most cases, maintain
a lower pressure (less than 1 lb) in the boiling tank than
a longer route with many elbows.

CAUTION:  There  is  to  be  NO  RESTRICTION  in  the  STEAM  PIPES
BETWEEN the STEAM GENERATOR and the STEAM NOZZLES that
would  in  any  way  cause  PRESSURE  to  build  in  the  STEAM
GENERATOR. INSTALL the STEAM NOZZLE 12" above the finished
flooring, in a LOCATION where the STEAM WILL NOT BURN anyone.

During  the  final  installation,  the  steam  nozzles  supplied
MUST  be  used.    See  “Steam  Piping  to  Bath  or  Shower”.

“CAUTIONS 1 and 3"

 and 

Fig. 2

.

TIMER   SWITCH

    (Steam  Generator  Control.)

The Quick Touch Timer can be located inside or outside the
steam room.  If using the optional Time and Temperature
Control, refer to that control's installation instructions now.
Relax-A-Mist  Timer  Switches  are  not  a  precision  timing
device.   See 

“CAUTION  11”

DRAIN  VALVE  OPTION

  (Ask  Dealer  For  Details)

A 3/4 inch copper, female adapter (located below the water
supply connection), can be plumbed to a drain with either a
manual shut off or an automatic drain valve installed at the
steam generator (purchased separately) See Figure 2.

2. ROUGH-IN
WATER SUPPLY

 (According to Local Plumbing Code)  The

water supply pipe should be equipped with a shut off that is
accessible and close to the steam generator.  Installation of
a water hammer arrester (water bumper) is recommended.

To maintain a proper water level in the generator the water
supply should have a minimum of 20 lbs pressure.  If the
water  supply  contains  impurities  that  could  cause  scale
build-up or corrode the steam generator, install appropriate
water  treatment.  See 

“CAUTION  4"  and  “WARRANTY

POLICY”

.  See diagrams on 

Page 6

.