background image

INSTALLATION AND MAINTENANCE 

MANUAL

REXENER

 

Mass Filter 

Summary of Contents for Mass Filter

Page 1: ...INSTALLATION AND MAINTENANCE MANUAL REXENER Mass Filter ...

Page 2: ...TOR VALVE 5 4 OPERATION 5 4 1 PRIMING THE FILTER 6 4 2 FILTRATION 6 4 3 FILTER BACKWASHING 6 4 4 DRAINING THE POOL 6 4 5 RINSING 6 4 6 RECIRCULATION ONLY PERFORMED BY A 6 WAY VALVE 7 5 CABLE REPLACEMENT 7 6 MAINTENANCE 7 7 TROUBLE SHOOTING AND TECHNICAL ASSISTANCE 15 GUARANTEE CERTIFICATE 15 1 GENERAL TERMS 15 2 INDIVIDUAL TERMS 15 3 LIMITATIONS 16 EVIDENCE OF CONFORMITY ...

Page 3: ...ate the unit unless it is properly primed NEVER touch the filter when it is operating if you are wet or have wet hands When handling the filter or valve DISCONNECT the power supply Make sure that the ground is dry before touching the electrical equipment Do not submerge the or put it in a place where it could be submerged Do not permit children or adults to sit or lean on the unit Children should ...

Page 4: ...llation process if in doubt contact the vendor of the unit 2 2 ASSEMBLY Once the unit is in place proceed as follows See pages 10 to 14 1 Attach filter to the mass filter according to model Ø300 Pag 10 14 Fix the pump to the base with the screws and washers supplied 2 Place the inner collector correctly on the bottom of the filter Cover the mouth of the collector situated on the inside of the filt...

Page 5: ...RATE THE MATERIALS OF THE UNIT AND LIMIT ITS EFFICIENCY Whenever chemical products are used to treat the pool water it is recommended that the minimum filtration time is respected in order to protect bathers health as stated by the health regulations 4 1 PRIMING THE FILTER The filter must be correctly primed at all times If the filter is not primed this means that an air chamber has been created i...

Page 6: ...until the front rib is in line with the backwashing mode Connect a hose to the valve waste outlet from the valve and direct the other end of the hose to a drain or sewer Run the filter for approximately 2 minutes until impurities no longer run out with the water Stop the unit Put the valve in the rinse position and connect the filter for a few seconds Stop the unit put it in the desired filter pos...

Page 7: ...ck that the filter is correctly primed The unit is designed to work so that practically no maintenance is required Some consumables or components subject to wear and tear may have a shorter service live than the unit s warranty period Contact your service engineer for any maintenance work that may be required 7 TROUBLE SHOOTING AND TECHNICAL ASSISTANCE This filter and its instructions are especial...

Page 8: ...lter The flow rate of the filter is low Due to use the filter is dirty The filter is not primed Perform a backwash Prime the filter Water comes out through the mouth of the filter The connection between the valve and the filter is dirty The metal band is loose Clean the sand from the opening In sert the coupling on the valve proper ly and tighten the metal band firmly The filter valve leaks throug...

Page 9: ...emplary Only in some models 5 functions valve Metallic clamp Connection hose Ø38 Pressure gauge set Closing band assembly Collector filter assembly Filter body Filter purgue assembly Mass filter base Screw M8x30 DIN933 Washer M8 DIN125 Pump ...

Page 10: ...10 1 Ø300 mm Images of the products are exemplary 2 Ø300 mm ...

Page 11: ...11 3 Ø300 mm 4 Ø300 mm RETURN PUMP ...

Page 12: ...12 5 Ø300 mm Installing the pressure gauge 6 Ø300 mm Installing the pump hose ...

Page 13: ...13 Figures FIG 1 FIG 2 CAUTION PUMP PUMP OK WRONG CLAMP FIG 3 FIG 4 ...

Page 14: ...14 Figures FIG 4A OK PLACE THE CLAMP FOLLOWING THE FILTER TANK LINE Keep the same distance when tightening the screws WRONG FIG 5 FIG 6 PUMP SKIMMER RETURN INLET PUMP ...

Page 15: ...must strictly follow the manufacturer s instructions included in the documentation accompanying the Product if said documentation is applicable depending on the range and model of the Product 2 4 When a schedule is given to replace maintain or clean certain parts or components of the Product the guarantee will only be valid if this schedule has been followed correctly 3 LIMITATIONS 3 1 This guaran...

Page 16: ...tic fields of household appliances and similar apparatus with regard to human exposure 1907 2006 EC REACH SIGNED THE PRESENT CONFORMITY EVIDENCE SIGNATURE 07 05 2021 Recycling This symbol is required by European Community Directive 2012 19 UE on WEEE Waste Electrical and Electronic Equipment and means that your appliance must not be thrown into a normal bin It will be selectively collected for the...

Page 17: ...3 5m3 h Sand filling 25 KG Grain Size 0 4 0 8 mm Filtration speed 50m3 m2 h Power 1 3 CV Voltage 230V 50Hz 09443 0008 Rev 00 We reserve the right to change all or part of the features of the articles or contents of this document without prior notice ...

Page 18: ...Technical support and service North UK Service I 44 7538 959 818 South UK Service I 44 75 3895 9836 Customer Support I 013 553 773 70 service rexnordic com ...

Reviews: