GAS CONVERSION KIT INSTALLATION FOR GAS-FIRED INDOOR 
HEATER

Supersedes:  CP-CAUA-GC (01-18) PN170635R9

MODEL CAUA

GENERAL INFORMATION

The gas conversion kits in these instructions are for model CAUA heaters equipped with specific single-stage or 

two-stage gas valves. The kits are for operation at sea level. When converting a unit with a two-stage valve (option 

AG2), check for the valve manufacturer. If the unit has a two-stage White-Rodgers valve, a new two-stage gas valve 

is required.

Gas Valve Identification

In order to verify which conversion kit is compatible with your heater, it is necessary to know the type of gas valve on 

the heater. Refer to the unit rating plate for the complete model number of the heater. Also, refer to the manufacturer’s 

name and number found on the gas valve. Match the model number of the valve to the one listed in the kit—if different, 

contact your manufacturer representative to select and verify parts required for gas conversion.

Important Safety Information

Please read all information in this manual thoroughly and become familiar with the capabilities and use of your 

appliance before attempting to operate or maintain this unit. Pay attention to all dangers, warnings, cautions, and 

notes highlighted in this manual. Safety markings should not be ignored and are used frequently throughout to 

designate a degree or level of seriousness.

DANGER: 

A danger statement describes a potentially hazardous situation that if not avoided, will result in severe 

personal injury or death and/or property damage.

WARNING: 

A warning statement describes a potentially hazardous situation that if not avoided, can result in severe 

personal injury and/or property damage.

CAUTION:

 A caution statement describes a potentially hazardous situation that if not avoided, can result in minor 

or moderate personal injury and/or property damage.

NOTE: 

A note provides important information that should not be ignored.

 ⚠ DANGER ⚠ 

 

FIRE OR EXPLOSION HAZARD

 

• Failure to follow safety warnings exactly could result in serious injury, death, or property 

damage.

 

• Improper installation, adjustment, alteration, service, or maintenance can cause serious injury, 

death, or property damage.

 

• Installation and service must be performed by a qualified installer, service agency, or the gas 

supplier.

 

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 

any other appliance.

WHAT TO DO IF YOU SMELL GAS

 

• Do not try to light any appliance.

 

• Do not touch any electrical switch; do not use any phone in your building.

 

• Leave the building immediately.

 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

DO NOT DESTROY. PLEASE READ CAREFULLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

Summary of Contents for CAUA

Page 1: ...ot be ignored and are used frequently throughout to designate a degree or level of seriousness DANGER A danger statement describes a potentially hazardous situation that if not avoided will result in severe personal injury or death and or property damage WARNING A warning statement describes a potentially hazardous situation that if not avoided can result in severe personal injury and or property ...

Page 2: ...combustion system install either the horizontal or vertical combustion air ventsystemillustratedintheheaterinstallationmanual usingtheconcentricadaptersupplied All installations must comply with the combustion air requirements in the installation codes and instructions Units installed in a confined space must be supplied with air for combustion and ventilation as required by code and in the heater...

Page 3: ...Size Kit PN Component Description PN Gas Valve Model No All LP to NG spring kit HW 394588 for single stage valve VR8105 VR8205 or VR8305 98721 Tape Conversion 64391 Disk Natural Gas 1401 150 269833 LP to NG spring kit HW 396222 for single stage valve VR8215 261651 Single stage HW VR8204M1018 VR8205M1148 or VR8215S5215 or two stage HW VR8304Q4412 Spring conversion kit HW 3906025 for two stage valve...

Page 4: ... 10 250 63003 1 20 mm 13 300 39658 56 15 350 87391 40 11834 54 12 400 11792 41 61652 1 45 mm 14 6001 7000 US 150 40414 48 39658 56 8 200 84583 47 10 250 13 300 15 350 11792 41 11834 54 12 400 84437 42 61652 1 45 mm 14 7001 8000 US 150 39651 49 63922 1 15 mm 8 200 84583 47 39658 56 10 250 63922 1 15 mm 13 300 39658 56 15 350 84437 42 11834 54 12 400 14 8001 9000 US 150 39651 49 63922 1 15 mm 8 200 ...

Page 5: ...g kits are not interchangeable Each kit must be used only in the model and type of gasvalveforwhichthekitisdesignated Verifycompatibilitybeforeinstallingtheregulatorspringkit a Select regulator spring kit that corresponds with gas valve on heater All gas conversion kits include one or two regulator spring kits for single stage valve and one regulator spring for two stage valve Other included regul...

Page 6: ...ws that secure manifold assembly and remove manifold assembly from heater c Carefully remove existing burner orifices d For all conversions select replacement burner orifices in accordance with Table 3 WARNING Do not attempt to drill burner orifice Use factory supplied orifice only e Install replacement burner orifices CAUTION Ensure that the manifold is positioned properly with relation to the bu...

Page 7: ...High Fire Two Stage Low Fire Natural Gas Propane Natural Gas Propane Manifold Outlet Pressure IN WC 3 5 10 0 1 8 5 0 Or as stated on the unit rating plate b Turn knob or switch on top of valve to OFF to prevent flow to gas valve NOTE A manometer fluid filled gauge is recommended rather than a spring type gauge due to the difficulty of maintaining the calibration of a spring type gauge Use a water ...

Page 8: ...rew IN clockwise to increase pressure or OUT counterclockwise to decrease pressure 3 Reconnect wire to Hi terminal on gas valve WARNING In the event of improper ignition wait at least 5 minutes before attempting to relight the heater f Turn up thermostat and cycle burner once or twice to properly seat adjustment spring in valve g Recheck outlet pressure When pressure corresponds to Table 5 disconn...