Page 1: ...Operational Instructions Glue Applicator MS 200 Translation from German to English ...

Page 2: ...2 Safety Measures to be taken during Operation 3 Start up and Control 4 Cleaning and Maintenance 6 Trouble Shooting 7 Environmental Protection 8 Additional Information 8 CE Declaration of Conformity 9 Spare Parts 10 Technical Data 11 Table of Contents ...

Page 3: ... applicator Eggenstein Leopoldshafen Germany 23rd of May 2011 The applicator works with non reactive hot melt glue which is dispensed by a mechanical conveying system Therefore this glue applicator should only be used by qualified persons who have been familiarized with the proper use and the safety precautions Handling the applicator properly will avoid unnecessary accident hazards and problems B...

Page 4: ...instructions Making the Information available This operating manual shall always be kept at the place of operation of the applicator Be sure that all persons handling the applicator can consult the instructions at any time In addition to this operating manual there must be available instructions regarding legal and other mandatory regulations relating to accident prevention and to relevant require...

Page 5: ...zzle Warning risk of burns When a nozzle is replaced liquid glue might leak out Never bring the hot nozzle into contact with the cable Never direct the glue jet towards people When your skin got into contact with hot glue cool it with cold water immediately Do not try to remove the hot melt from the skin first If necessary consult a doctor When hot adhesive got into your eyes immediately cool them...

Page 6: ...nsed at once and vice versa Avoid accidents by stumbling Lay all cables hoses and conducts so that they will not cause any risk of stumbling For this install cable ducts and bridges Wear protective gloves and safety goggles whenever you work with the applicator Never direct the glue jet towards people Never lay the hot melt applicator on its side Do not hold the nozzle top upward for too long Do n...

Page 7: ...es of up to max 200 C After the end of the heat up period approx 5 min open the lid by turning the star grip counter clockwise Load granulate up to 1 5 cm 0 6 inch under the lower rim of the feeding opening Open the lid by turning the star gripe counter clockwise Shut the lid and allow the applicator to melt the glue Wear protective gloves and safety goggles whenever you work with the applicator N...

Page 8: ...k of explosion If the applicator is used very often we recommend having it maintained regularly For this fix a date with our service department Further more the MS 200 can be put down on magnetic surfaces by using the magnetic foot In this case the wire stand is not needed and can stay folded in Replacement of Nozzles Warning risk of burns When your skin got into contact with hot glue cool it with...

Page 9: ...f possible fault indications and assistance in trouble shooting In case of damage send the glue applicator to Reka indicating type and serial no of your applicator We shall not be responsible for any repair made by yourselves ...

Page 10: ...elt glues and hot melt cartridges from the respective safety datasheet Additional Information Do you have any more questions or requests We should be glad to help you Please contact us by Phone 49 0 721 970780 Telefax 49 0 721 705069 E Mail sale reka klebetechnik de Our mailing address is Reka Klebetechnik GmbH Co KG Siemensstr 6 D 76344 Eggenstein Internet http www reka klebetechnik de RHEOLOG RH...

Page 11: ...2009 89 336 EEC from 29 12 2009 2006 42 EC 2002 95 EC The following standards have been applied IEC CISPR14 IEC 60335 IEC 60204 IEC 61000 This declaration of conformity shall get invalid if the product is modified extended or otherwise changed without express approval of Reka Klebetechnik GmbH Co KG and or other components than accessories of Reka Klebetechnik are fitted and if the product is not ...

Page 12: ...Spare Parts Lid MS 200 Nozzle MS 200 ...

Page 13: ...tection IP 30 Temperature control Thermostat Temperature limitation Temperature controller Operating temperature 20 200 C 70 390 F Temperature constancy 5 C Heat up time appox 5 min Gross tank capacity 250 ml Conveying system Mechanics Length of electric cable 1 8 m Recommended melts Hot melt granulate pillows and 43mm 1 7 Sticks Technical Data Stand 2011 10 ...