background image

WARNING

Read these instructions, the tool instructions and the warn-
ings and instructions for all equipment being used before op-
erating this tool to reduce the risk of electrical shock or
other serious personal injury.

Use the RIDGID

® 

RPA 120/220 AC Power (Mains) Adapter

only with the RIDGID

®

RP 340 Press Tool.

Other uses or mod-

ifying the AC Power Adapter for other applications may damage
the equipment and/or cause personal injury.

Do not probe AC Power Adapter terminals with conductive
objects. 

Shorting of terminals may cause sparks, burns or elec-

trical shock.

Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the tool. Keep cord away from heat, oil,
sharp edges or moving parts. 

Damaged or entangled cords in-

crease the risk of electric shock.

Always unplug the adapter from the outlet before removing
the adapter from the tool.

This will reduce the risk or electrical

shock.

Do not use in damp, wet or explosive environment.

Do not ex-

pose to rain, snow or dirt. Contaminants and moisture increase
the risk of electrical shock.

If operation in a damp location is unavoidable, use a ground
fault circuit interrupter (GFCI) protected supply. 

Use of a

GFCI reduces the risk of electrical shock.

AC Power Adapter plug must match the outlet. Never mod-
ify the plug in any way.

Unmodified plugs and matching outlets

will reduce risk of electric shock.

Use an appropriate power source. Do not attempt to use a
step-up transformer, an engine generator or DC power re-
ceptacle.

May cause damage to AC Power Adapter resulting in

electrical shock, fire or burns.

Avoid body contact with earthed or grounded surfaces
such as pipes, radiators, ranges and refrigerators.

There is

increased risk of electrical shock if your body is earthed or
grounded.

Do not open the AC Power Adapter housing.

Have repairs

performed only at authorized locations.

The EC Declaration of Conformity (890-011-320.10) will accom-
pany this manual as a separate booklet when required.

If you have any questions concerning this RIDGID

®

product:

• Contact your local RIDGID distributor.
• Visit www.RIDGID.com to find your local RIDGID contact point.
• Contact RIDGID Technical Services Department at rtctechser-

vices.com, or in the U.S. and Canada call (800) 519-3456.

Description

The RIDGID RPA 120/220 AC Power Adapter is designed to be
used in place of the battery in the RIDGID RP 340 Press Tool to
allow the tool to be operated off an appropriate AC power source
(wall outlet). 

Specification

Input ....................Available for 120V AC or 220V AC

Output ....................18V

Power Cord 
Length....................16.4 ft (5m)

Weight....................2.1 lbs (1.0 kg)

Dimension..............4.9" x 3.1" x 2.7" 

(124 x 78 x 69 mm)

Temperature 
Range ..................14°F to 140°F (-10°C to 60°C)

Cooling ................Passive convection cooling (no fan)

While the RIDGID RPA 120/220 AC Power Adapter will

physically fit onto and power other RIDGID 18V battery powered
equipment, use with equipment other than the RIDGID RP-340
Press Tool has not been evaluated to appropriate standards (ie.
UL/CSA/CE) and is not recommended.

Icons

Double Insulated

Figure 1 – AC Power (Mains) Adapter Label

Inspection/Maintenance

Make sure the AC Power Adapter is unplugged. Clean the AC
Power Adapter with a soft cloth to aid inspection and control. In-
spect before each use for proper assembly, wear, damage or other
issues that could affect safe use. Make sure that the cord and plug
are not damaged. Confirm that the markings are present and read-
able. Do not use if any issues are found.

Set-

Up/Operation

Make sure all equipment is inspected and set up per its instruc-
tions.

1. Confirm that the AC Power Adapter is unplugged from any

power source and securely insert the AC Power Adapter into
tool battery port.

2. Run the cord along a clear path, and with dry hands plug the

AC Power Adapter into an appropriate power source. If the
power cord is not long enough, use an extension cord that:
• Is in good condition.
• Is appropriately rated for the use.
• Has sufficient wire size (16 AWG for 50' or less, 14 AWG for

50' to 100'). Undersized wires can overheat, melting the in-
sulation or causing fire or other damage.

Confirm the Red LED is ON and solidly illuminated. If the Red
LED is flashing;

• An excessive initial temperature or temperature increase

has occurred (Temperature Protection).

• A short circuit has occurred (Short Circuit Protection) or

overload protection.

• The Adapter is not working properly.
Unplug the AC Adapter from the power source and allow a
minimum of 5 minutes to cool down. The internal thermal over-
load will reset itself. If this does not solve issue, have adapter
serviced.

3. Operate the tool as per its instructions, following duty cycle.

4. Unplug AC Power Adapter with dry hands when not in use. Al-

RIDGID

®

© RIDGID, Inc. 12/13

EC40379

999-999-465.10

REV. B

For Indoor Use Only

NOTICE

Catalog

Plug 

No.

Voltage

Product Region

Type

44823

120V

China AC Power Adapter

A

43338

220V

Europe AC Power (Mains) Adapter

C

44468

120V

North America AC Power Adapter

A

RPA 120/220 AC Power (Mains) Adapter Instructions

Summary of Contents for 44823

Page 1: ... Tool to allow the tool to be operated off an appropriate AC power source wall outlet Specification Input Available for 120V AC or 220V AC Output 18V Power Cord Length 16 4 ft 5m Weight 2 1 lbs 1 0 kg Dimension 4 9 x 3 1 x 2 7 124 x 78 x 69 mm Temperature Range 14 F to 140 F 10 C to 60 C Cooling Passive convection cooling no fan While the RIDGID RPA 120 220 AC Power Adapter will physically fit ont...

Page 2: ... choc électrique La prise de l adaptateur de courant CA doit être adaptée à la prise de courant Ne modifiez jamais la prise d aucune manière Les prises non modifiées et les prises adaptées ré duisent le risque de choc électrique Utilisez une source d alimentation appropriée Ne tentez pas d utiliser un transformateur élévateur de tension un généra teur de moteur ou une prise d alimentation électriq...

Page 3: ... Selon la norme européenne 2002 96 EC visant le recy clage des déchets électriques et électroniques et sa mise en application au niveau national tout matériel électrique hors d usage doit être récupéré séparément et recyclé de manière écologiquement responsable Instrucciones para el adaptador de electricidad de CA red RPA 120 220 ADVERTENCIA Lea estas instrucciones las instrucciones del aparato y ...

Page 4: ...n el Lineamiento Europeo 2002 96 EC para Desechos de Equipos Eléctricos y Electrónicos y su implementación en la legislación nacional los equipos eléctricos inservibles deben desecharse por separado en una forma que cumpla con las normas del medio ambiente Si tiene alguna pregunta acerca de este producto RIDGID Comuníquese con el distribuidor RIDGID en su localidad Visite www RIDGID com para averi...

Reviews: