background image

1

Your roofing coil nailer has been engineered and manufactured to our high standards for dependability, ease of operation, 
and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.

WARNING:

To reduce the risk of injury, the user must read and understand the operator’s manual before using this product.

Thank you for buying a RIDGID product.

SAVE THIS MANUAL FOR FUTURE REFERENCE

OPERATOR’S MANUAL

ROOFING COIL NAILER

R175RND

Summary of Contents for R175RND

Page 1: ...tor safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for buying a RIDGID product SAVE THIS MANUAL FOR FUTURE REFERENCE OPERATOR S MANUAL ROOFING COIL NAILER R175RND ...

Page 2: ...intenance 18 19 Accessories 20 Troubleshooting 20 Warranty 21 Customer Service Information Back Page TABLE OF CONTENTS INTRODUCTION This tool has many features for making its use more pleasant and enjoyable Safety performance and dependability have been given top priority in the design of this product making it easy to maintain and operate ...

Page 3: ...parts Keep fingers away from trigger when not driving fasteners to avoid accidental firing GENERAL SAFETY RULES Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations Use safety equipment Always wear eye protection Dust mask nonskid safety shoes hard hat or hearing protection must be used for appropriate ...

Page 4: ...tached Do not operate this tool if it does not contain a legible warning label Do not continue to use a tool that leaks air or does not function properly SPECIFIC SAFETY RULES OPERATION Always assume that the tool contains fasteners Do not carry the tool from place to place holding the trigger Accidental discharge could result Always handle the tool with care Respect the tool as a working implemen...

Page 5: ...causing injury or death Do not use with an air compressor which can potentially exceed 200 psi as tool may burst possibly causing injury The connector on the tool must not hold pressure when air supply is disconnected If an incorrect fitting is used the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly ca...

Page 6: ...learn their meaning Proper interpretation of these symbols will allow you to operate the tool better and safer Read The Operator s Manual Safety Alert SYMBOL NAME DESIGNATION EXPLANATION To reduce the risk of injury user must read and understand operator s manual before using this product Eye Protection Precautions that involve your safety Hot Surface To reduce the risk of injury or damage avoid c...

Page 7: ...tem that allows discrete selection of two or more of the following actuation systems single sequential actuation full sequential actuation or contact actuation One or more of the selections shall be single sequential actuation or full sequential actuation Air inlet port In an air tool the opening to which the compressed air supply is connected usually by means of a threaded fitting Coil nailer A n...

Page 8: ...SELECTABLE TRIGGER REPLACEABLE NOSEPIECE WORKPIECE CONTACT PRODUCT SPECIFICATIONS Operating Pressure 70 120 psi Magazine Capacity 120 nails Air Consumption 05 ft3 cycle at 100 psi Air Inlet 3 8 in NPT Weighted sound impulse power level 96 5 dBA Emission sound pressure level 84 2 dBA Vibration 3 57 m s2 Weight 5 1 lbs ...

Page 9: ...us nail sizes IN HANDLE AIR FILTER The self cleaning in handle air filter helps keep debris out to extend the life of the tool INTERNAL PISTON CATCH The internal piston catch delivers consistent driving power MAGNETIC NAIL HOLDER The magnetic nail holder allows for easy loading and maintains nail position down to the last fastener MUFFLER The muffler reduces noise during operation QUICK CONNECT SW...

Page 10: ...ARNING Do not attempt to modify this tool or create accessories not recommended for use with this tool Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury UNPACKING This product has been shipped completely assembled Carefully remove the tool and any accessories from the box Make sure that all items listed in the packin...

Page 11: ...nto the air fitting on the tool once daily with minimal use or twice a day with heavy use Only a few drops of oil at a time is necessary Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle Before connecting the tool check the air compressor gauge to be sure it is functioning within the proper range of 70 120 psi ADJUSTING THE EXHAUST See Figure 3 The adjustab...

Page 12: ...pressure that is higher than 120 psi may damage the tool The tool and air hose must have a hose coupling that allows all pressure to be removed from the tool when the coupling is disconnected WARNING Always use a coupling that discharges all the compressed air in the tool at the time the fitting or hose coupling is disconnected Using a coupling that does not discharge the compressed air could caus...

Page 13: ...t indicator inside the magazine to help you choose the right position To adjust the magazine pull up on the spool and rotate it until the nail tray rests in place in the desired position Rotate it counterclockwise to lower the nail tray Turn it clockwise to raise the nail tray Position Nail Size Position 1 3 4 in 7 8 in 1 in Position 2 1 1 4 in Position 3 1 1 2 in 1 3 4 in SPOOL Fig 5 Fig 6 POSITI...

Page 14: ...ING Never load nails with the workpiece contact or trigger activated Doing so could result in possible serious personal injury Connect the tool to the air supply Depress the feeder cover latch and open the cover Open the magazine cover Slide the coil of nails onto the spool with the nails pointing down Uncoil about 3 in of nails from the coil of roofing nails Insert the first nail into the feeder ...

Page 15: ...CTUATION MODE Contact actuation allows very fast repetitive fastener placement Disconnect the tool from the air supply Depress the trigger lever pivot pin Rotate the selector to Position B Release the trigger lever pivot pin NOTE The trigger lever pivot pin is spring loaded and held in position by locking tab to prevent movement during operation Reconnect the tool to the air supply Grip the tool f...

Page 16: ... alone If finer adjustments are needed use the drive depth adjustment on the tool DRIVE DEPTH ADJUSTMENT See Figure 12 The driving depth of the nail may be adjusted It is advisable to test the depth on a scrap workpiece to determine the required depth for the application To determine depth of drive first adjust the air pressure and drive a test nail To achieve the desired depth use the drive depth...

Page 17: ...ct the tool from the air supply Open the feeder cover and magazine cover see Loading the Tool with Nails Lift the nail strip from the spool and remove the remaining coil of nails CLEARING A JAMMED FASTENER See Figure 14 If a nail or fastener becomes jammed in the tool disconnect the air hose and keep the tool pointed away from you while clearing the jam Disconnect the tool from the air supply Open...

Page 18: ...lways wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust If operation is dusty also wear a dust mask WARNING Disconnect the tool from the air supply before performing maintenance Failure to do so could result in serious personal injury GENERAL MAINTENANCE Avoid using solvents when cleaning plastic parts Most plastics are susceptible to damage f...

Page 19: ... several times Hold the trigger in this position for a minimum of 5 seconds The tool must not operate Press the workpiece contact firmly against the workpiece Pull the trigger The tool must operate With the workpiece contact still depressed release the trigger The driver must return to its up position Rotate the selectable trigger knob on the trigger to Contact Actuation operation Position B as sh...

Page 20: ... damaged O rings or bumper Incorrect fasteners Damaged fasteners Loose magazine or nose screws Dirty magazine Worn or damaged driver Verify that fasteners are the correct size Replace fasteners Tighten screws Clean magazine Install Driver Maintenance Kit ACCESSORIES To order parts and maintenance kits call 1 866 539 1710 Driver Maintenance Kit 079006001111 Overhaul Kit 079006001110 Oil and Wrench ...

Page 21: ...ed service center will repair any faulty workmanship and either repair or replace any part covered under the warranty at our option at no charge to you One World Technologies Inc P O Box 35 Hwy 8 Pickens SC 29671 WHAT IS NOT COVERED This warranty applies only to the original purchaser at retail and may not be transferred This warranty only covers defects arising under normal usage and does not cov...

Page 22: ... location of the authorized service center nearest you please call 1 866 539 1710 or visit us online at www ridgid com The model number of this tool is found on a plate attached to the magazine cover of the tool Please record the serial number in the space provided below When ordering repair parts always give the following information Model No Serial No R175RND OPERATOR S MANUAL ROOFING COIL NAILE...

Reviews: