background image

cod

. 20

129

5

36

  r

e

v.

 2

03

/2

0

19

INSIEME EVOe 32 B/110 LN

EN

  USER MANUAL

Summary of Contents for INSIEME EVOe 32 B/110 LN

Page 1: ...cod 20129536 rev 2 03 2019 INSIEME EVOe 32 B 110 LN EN USER MANUAL ...

Page 2: ...must be observed to ensure the trouble free installation and efficient functioning of your INSIEME EVOe 32 B 110 LN boiler Please accept our renewed thanks for your purchase Riello S p A CONFORMITY INSIEME EVOe 32 B 110 LN boilers conform to the following di rectives Directive 92 42 EEC on efficiency requirements Electromagnetic Compatibility Directive 2014 30 EU Low Voltage Directive 2014 35 EU E...

Page 3: ... 6 1 6 Control panel 7 1 7 Menu navigation 9 1 8 Navigation scheme 11 1 9 List of user parameters 12 2 USE 14 2 1 Putting into service 14 2 1 1 Preliminary operations 14 2 1 2 Start up 14 2 1 3 Adjustment of heating setpoint 15 2 1 4 Enable disable the heating function 15 2 1 5 Adjustment of domestic setpoint 15 2 1 6 Enable disable the domestic function 15 2 1 7 Special functions 16 2 1 8 Ignitio...

Page 4: ...e used for an extended peri od of time perform the operations described later in this manual 9 9This manual is an integral part of the equipment and there fore must be stored carefully and must ALWAYS accompany the boiler even if it is sold to another Owner or User or trans ferred to another plant If it is damaged or lost request an other copy from your local Technical Assistance Service R 1 2 Pre...

Page 5: ...eds the limit threshold of 3 bar Pressure transducer sends a signal to the electronic reg ulator which views and continually checks the primary circuit pressure to switch on the generator or cause it to stop in case of low pressure Boiler temperature probes delivery and return im mersion probe on the delivery line of the generator is used by the regulator to view and check the delivery wa ter temp...

Page 6: ...sel 6 Control panel 7 Heating expansion reservoir 8 Burner 9 Boiler drain cock 10 Magnesium anode 11 Storage cylinder inspection flange 12 Storage cylinder flange insulation 13 Storage cylinder drain cock 14 Storage cylinder safety valve 15 Storage cylinder fill cock 16 Storage cylinder with insulation 17 Flame inspection window 18 Boiler body 19 Pump 20 Exhaust flue duct 21 Flue gas box cover 22 ...

Page 7: ...restoring the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and initialization in progress after the power supply reset Steady green Thermal unit on Steady red Thermal unit in alarm mode Red blinking Thermal unit in lock out mode ...

Page 8: ...ing the Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation is active Par 2001 1 or 2 6 Celsius Fahrenheit temperature 7 Displays current value 8 Displaying of system pressure or parameter number or external temperature 9 Icon displayed when the circulat...

Page 9: ...eating setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a permanent error Loc Additional functions Button Function with It accesses enable disable heating function mode It accesses enable disable DHW production function mode 9 9For more information see...

Page 10: ...is mode keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increases a certain parameter value 4 Selects the previous menu or decreases a certain parameter value 5 ENTER RESET Enters into the selected menu parameter or confirms the parameter change ...

Page 11: ...11 GENERAL INFORMATION 1 8 Navigation scheme Modalità visualizzazione base Modalità utente Bar C oppure Example of parameter setting change confirmed change canceled or or or ...

Page 12: ...rol accessory this parameter can be used to quickly change Zone 3 setpoint This parameter simultaneously modifies the value of Par 2303 See Par 2303 See Par 2303 C 0000 047 Quick adjustment of DHW setpoint with heater See Par 2047 C 0000 048 Quick adjustment of DHW setpoint with instant production See Par 2048 C 0000 201 Stops the venting function 0 No action 1 Stop venting 0 1 0 0000 901 Unit of ...

Page 13: ...irect Zone Zone 1 climatic curve 10 10 0 C Zone 2 Heating Settings 2000 2203 Zone 2 heating setpoint in 0 and 3 heating modes The thermal unit adjustment determines the boiler setpoint in heating mode using the highest value among the requests of all the active zones Par 1101 1201 1301 If Zone 2 is configured as mixed the value set in parameter 1113 will be used as setpoint BT Par 2221 45 AT Par 2...

Page 14: ...C close the system load valve 2 1 2 Start up Once you have completed all the checks listed above proceed as follows to start up the boiler for the first time set the main switch of the system to ON and the main switch of the equipment to I Upon switching on the display of the control interface of the device shows the following pages in sequence HEAT Bar Bar C F Psi Psi OUTSIDE Firmware version of ...

Page 15: ...Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3 seconds or press the key ENTER RESET Check that the thermal unit starts the ignition phase and that the display shows the icon blinking ambient heating request and the icon The boiler now starts up and the burner remains lit until the temp...

Page 16: ...t the first start up and at each reset of the power supply When the function is active the message Air is displayed During the venting the circulator is enabled so that the air which may be present inside the system circuit can exit through the automatic drain valve of the device The status of the light guide changes to flashing green Circulator and 3 way valve activation every 24 hours Every 24 h...

Page 17: ...e Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MAN AGEMENT MUST ENSURE THAT PROFESSIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS R s Technical Assistance Service is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to guarantee Greater safety Compliance with ...

Page 18: ... from the ambient thermostat is missing Check the temperature set on the am bient thermostat Contact your local Technical Assistance Service Insufficient domestic hot water or water not hot enough Diverter valve or pump faulty Contact your local Technical Assistance Service Domestic setpoint Check the temperature setting Contact your local Technical Assistance Service 3 RECYCLING AND DISPOSAL The ...

Page 19: ...19 ...

Page 20: ...llo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Reviews: