Page 1: ...Guangzhou Geliang Lighting Technology Co Ltd Tel 8620 86872001 2 3 www rigelighting com RG W15IB15 KF3A USER MANUAL 15W3Leds Wall Washer ...

Page 2: ...TIONS 2 4 SCHEMATIC DIAGRAM 3 5 PRODUCT FEATURES 4 6 TECHNICAL SPECIFICATIONS 4 7 MOUNTING AND INSTALLATION 5 8 UNDERSTANDING DMX 6 9 CONTROL BOARD 8 10 Wireless DMX WDMX System 10 11 DMX CHANNEL TRAITS 11 12 MAINTENANCE AND CLEANING 12 13 1 YEAR LIMITED WARRANTY 13 ...

Page 3: ... instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below CUSTOMER SUPPORT We provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www rigelighting com for any comments or suggestions For servi...

Page 4: ...r two of this manual Operating the Eight head beam bar without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury 5 Only qualified and certified personnel should perform installation 6 When mounting this fixture use only the original rigging parts included with this fixture Any structural modification will void the original manufactures warran...

Page 5: ...15W3lLeds Wall Washer 3 4 SCHEMATIC DIAGRAM ITEM FUNCTION 1 Power supply input output 2 Dual hanging bars 3 LED display board 4 Fixed knob 5 DMX input output 6 LED model 7 Safety buckle ...

Page 6: ...ower Led 15W pcs RGB 3IN1 Service Life 50000 Hrs Beam angle 60 Protect Level IP30 Power adapter Input AC100 240V 50 60HZ Power Consumption 45 Watts Working Temperature 20 40 Weights and Measures lengthXwidthXheigth mm 375x120x139 447x120x160 including of dual hanging bars Net Weight 3 7 Cross Weight 4 2 Package Size 7 MOUNTING AND INSTALLATION Cautions For added protection mount the fixtures in ar...

Page 7: ...asure to prevent accidental damage and or injury in the event the clamp fails Mounting points Overhead mounting requires extensive experience including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation you...

Page 8: ... pin or 5 pin XLR connector for data input and data output the figure on the next page is of a 3 Pin XLR connector If you are making your own cables be sure to use two conductor shielded digital DMX cable rated at 120 ohms this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers Your cables should be made with a male and f...

Page 9: ...ngs of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the Fixture which is a 3 channel fixture you sho...

Page 10: ...s Wall Washer 8 9 CONTROL BOARD 9 1 ADDR This function is used to set or adjust the fixture s starting DMX address Every device controlled by DMX has to have a unique starting address The addressing feature is ...

Page 11: ...el mode 3 DMX channal 9 3 Manual Mode This function is used to set the mixed color by manua Including of rL gL bL EL four parts This setting will store in the build in menmory You can use this setting next time without reset 9 4 Automatic Mode This function including FLAS FADE ACS CE CS five modes which allows the internal programs to run in either stand alone or master salve mode In CS mode this ...

Page 12: ...lue dimmer CH6 0 Strobe off 1 255 Strobe effect slow to fast CH1 129 255 CH1 129 255 Four section mode open CH2 0 255 Total dimmer 0 100 CH3 0 255 Red dimmer 0 100 first section CH4 0 255 Green dimmer 0 100 CH5 0 255 Blue dimmer 0 100 CH6 0 255 Red dimmer 0 100 second section CH7 0 255 Green dimmer 0 100 CH8 0 255 Blue dimmer 0 100 CH9 0 255 Red dimmer 0 100 third section CH10 0 255 Green dimmer 0...

Page 13: ... the installation spot and usage have to be adhering by a skilled installer and any safety problems have to be removed In order to make the fixture in good condition and extend the life time we suggest a regular cleaning to the fixture 1 Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust 2 A detailed electric check by approved electrical eng...

Page 14: ...orb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of us under this warranty shall be limited to the repair of the product or replacement thereof including fixturets at the sole discretion of us E Our company reserves the right to make changes in design and or improvements upon its products without any obligation to includ...