background image

www.BC-Discount.com

+33 (0) 1 82 83 62 06 - contact@bc-discount.com

AgileBio SARL, 16bis quai Jean Baptiste Clément, F-94140 ALFORTVILLE

LS6000B

Laser Barcode Scanner

Quick guide

Summary of Contents for LS6000B series

Page 1: ...www BC Discount com 33 0 1 82 83 62 06 contact bc discount com AgileBio SARL 16bis quai Jean Baptiste Clément F 94140 ALFORTVILLE LS6000B Laser Barcode Scanner Quick guide ...

Page 2: ...cradle to the host For power supply the charging cradle of LS6000B also works as a battery charger for the scanner Users can plug in 5V DC power adaptor for power charge of the scanner The laser module we adopt is compliant with IEC60825 Class II Package of LS6000B series should contain 1 LS6000B Laser Barcode Scanner Rechargeable Li Ion battery pack inside 2 Charging Cradle with USB cable DC plug...

Page 3: ...03 Driver Installer exe to the host system for LS6000B series 3 Connect scanner cradle to the USB port on the host system Once link the red led light on scanner will off In case it still keeps ON please re plug the USB connector again and click on reset button shown on picture That circle on red color 4 Go to My Computer One click right button of mouse Administrate Device Administrator Connect Por...

Page 4: ...igure 1 to Figure 3 Figure 1 Figure 2 Figure 3 3 No need to key in No need to key in Step 1 key in the identify COM number Step 1 key in a file name Step 2 select the first icon Step 3 press OK Step 2 press OK Step 1 key in the identify COM number ex COM 5 Step 2 press OK ...

Page 5: ...Configuration to Defaults barcode This will reset the scanner to its factory settings LS 6000B Tip Do not hold the scanner directly over a barcode at 90 Scanning light bounces directly back into the scanner from the barcode label is known as specular reflection which will create a dead zone where decoding is difficult Practice a 4 Row 1 key in 9600 Row 2 key in 8 Row 3 key in none Row 4 key in 1 R...

Page 6: ...ot installed and used in accordance with the instructions manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the party responsible for compliance could void the ...

Page 7: ...conditions failure to follow the instructions and warnings or misuse or alteration or repair of the products without written approval 6 ...

Page 8: ...Setup from Bar Code Label 7 ...

Page 9: ...601 GOOD READ BEEP TONE NONE BUZZER LED GOOD READ BEEP TONE RESET 014200 0B142 DECODE OPTIONS REVERSE IMAGE ENABLE IMAGE DECODE OPTIONS REVERSE IMANGE DISABLE 01391 01390 DECODE OPTIONS SEND BAR CODE ID DISABLE CODE ID DECODE OPTIONS SEND BAR CODE ID AS A PREFIX 01400 01401 DECODE OPTIONS SEND BAR CODE ID RESET DECODE OPTIONS SEND BAR CODE ID AS A SUFFIX 8 ...

Page 10: ...AN MODE SINGLE SCAN NO TRIGGER 013300 013301 SCAN MODE MULTISCAN SCAN MODE MULTISCAN NO TRIGGER 013302 013303 SCAN MODE PULSE 013305 LASER CCD TIMEOUT 5 SECONDS LASER CCD TIMEOUT 2 SECONDS 0134005 0134002 LASER CCD PULSE RATE 7 LASER CCD PULSE RATE 3 013507 013503 9 ...

Page 11: ...n WEDGE MODE SCAN SET 2 PASS THRU 000200 000204 TRANSMIT SPEED 0 TRANSMIT SPEED TRANSMIT SPEED 25 0000000 0000025 KEYBOARD COUNTRY USA LANGUAGE KEYBOARD COUNTRY GERMAN 0005000 0005010 KEYBOARD COUNTRY FRANCE KEYBOARD COUNTRY UNIVERSAL 0005009 0005025 10 ...

Page 12: ...4 SERIAL BAUD RATE 9600 SERIAL BAUD RATE 19200 000705 000706 SERIAL HANDSHAKE NONE HAND SHAKE SERIAL HANDSHAKE XON XOFF 001200 001201 SERIAL HANDSHAKE RTS CTS SERIAL HANDSHAKE ACK NAK 001202 001203 SERIAL HANDSHAKE TIMEOUT 2 SECONDS SERIAL HANDSHAKE TIMEOUT 5 SECONDS 0013020 0013050 11 ...

Page 13: ...ETERS SERIAL DATA BITS 7 00081 00080 SERIAL STOP BITS 1 SERIAL STOP BITS 2 00090 00091 SERIAL PARITY NONE SERIAL PARITY ODD 001000 001001 SERIAL PARITY EVEN SERIAL PARITY MARK 001002 001003 SERIAL PARITY SPACE SERIAL PARITY RESET 001004 0B010 12 ...

Page 14: ...Symbologies On Off 1 CODE 11 ENABLE CODE 11 CODE 11 DISABLE 01261 01260 CODE 39 ENABLE CODE 39 CODE 39 DISABLE 00221 00220 FULL ASCII ENABLE FULL ASCII DISABLE 00231 00230 13 ...

Page 15: ...20 CODE 128 ENABLE CODE 128 CODE 128 DISABLE 00691 00690 CODE 128 ISBT ENABLE CODE 128 ISBT DISABLE 00701 00700 CODABAR ENABLE CODABAR CODABAR DISABLE 00851 00850 I2OF5 ENABLE INTERLEAVED 2 OF 5 I2OF5 DISABLE 00961 00960 ID2OF5 ENABLE INDUSTRIAL 2 OF 5 ID2OF5 DISABLE 14 ...

Page 16: ...01061 01060 15 ...

Page 17: ...n Off 3 MSI ENABLE MSI MSI DISABLE 01151 01150 UPC A ENABLE UPC EAN UPC A DISABLE 00341 00340 UPC E ENABLE UPC E DISABLE 00351 00350 EAN 13 ENABLE EAN 13 DISABLE 00361 00360 EAN 8 ENABLE EAN 8 DISABLE 00371 00370 16 ...

Page 18: ...LASER CCD REDUNDANCY DISABLE 01321 01320 CODE 39 SS CHAR NONE CODE 39 CODE 39 SS CHAR 002700 002704 CODE 39 SEND START STOP CHARS ENABLE CODE 39 SEND START STOP CHARS DISABLE 00281 00280 CODE 39 ID CHARACTER a CODE 39 ID CHARACTER z 0031a 0031Z CODE 39 LASER CCD REDUNDANCY ENABLE CODE 39 LASER CCD REDUNDANCY DISABLE 00331 00330 17 ...

Page 19: ... DISABLE 00681 00680 CODE 128 ID CHARACTER g CODE 128 CODE128 ID CHARACTER Z 0081g 0081Z CODE 128 LASER CCD REDUNDANCY ENABLE CODE 128 LASER CCD REDUNDANCY DISABLE 00841 00840 CODABAR SEND START STOP CHARS ENABLE CODABAR CODABAR SEND START STOP CHARS DISABLE 00861 00860 CODABAR WIDE GAPS ALLOWED ENABLE CODABAR WIDE GAPS ALLOWED DISABLE 00901 00900 18 ...

Page 20: ...0950 I2OF5 CHECK DIGIT DISABLE Interleaved 2 of 5 I2OF5 CHECK DIGIT ENABLE 00970 00981 I2OF5 ID CHARACTER i I2OF5 ID CHARACTER Z 0104i 0104Z I2OF5 LASER CCD REDUNDANCY ENABLE I2OF5 LASER CCD REDUNDANCY DISABLE 01051 01050 ID2OF5 BAR START STOP ENABLE Industrial 2 of 5 ID2OF5 BAR START STOP DISABLE 01071 01070 ID2OF5 ID CHARACTER j ID2OF5 ID CHARACTER Z 0113j 0113Z 19 ...

Page 21: ... MSI ISBN ID CHARACTER f MSI ISBN ID CHARACTER Z 0053f 0053Z MSI LASER CCD REDUNDANCY ENABLE MSI LASER CCD REDUNDANCY DISABLE 01251 01250 EXPAND UPC E TO UPC A ENABLE UPC EAN EXPAND UPC E TO UPC A DISABLE 00381 00380 EXPAND UPC A TO EAN 13 ENABLE EXPAND UPC A TO EAN 13 DISABLE 00391 00390 CONVERT EAN 13 TO ISBN ENABLE CONVERT EAN 13 TO ISBN DISABLE 00481 00480 20 ...

Page 22: ... DIGIT DISABLE 00431 00430 SEND EAN 13 CHECK DIGIT ENABLE SEND EAN 13 CHECK DIGIT DISABLE 00461 00460 SEND EAN 8 CHECK DIGIT ENABLE SEND EAN 8 CHECK DIGIT DISABLE 00471 00470 UPC A ID CHARACTER b UPC A ID CHARACTER Z 0049b 0049Z UPC E ID CHARACTER c UPC E ID CHARACTER Z 0050c 0050Z EAN 13 ID CHARACTER e EAN 13 ID CHARACTER Z 0051e 0051Z 21 ...

Page 23: ...SBN ID CHARACTER f ISBN ID CHARACTER Z 0053f 0053Z UPC EAN SUPPLEMENTS DISABLE UPC EAN SUPPLEMENTS 2 DIGIT ONLY 00550 00551 UPC EAN SUPPLEMENTS 5 DIGIT ONLY UPC EAN SUPPLEMENTS 2 5 DIGIT 00552 00553 UPC EAN LASER CCD REDUNDANCY ENABLE UPC EAN LASER CCD REDUNDANCY DISABLE 00541 00540 22 ...

Page 24: ... CHARACTER EDIT 2 OFF 020002020000001 0B20002 EDIT 1 FILTER LEADING SPACES EDIT 1 OFF 020001030000032 0B20001 EDIT 1 FILTER TRAILING SPACES EDIT 1 OFF 020001040000032 0B20001 EDIT FILTER ALL CHARACTERS EDIT DISABLE FILTER OF ALL CHARS 020000050000045 0B20000050000045 EDIT INSERT LEADING ZERO EDIT DISABLE INSERT LEADING ZERO 020000060000000048 0B20000060000000048 23 ...

Page 25: ...PLACE WITH TWO FOR CODE 39 ONLY MACRO 2 DISABLED 0201023012TWO 0B20102 MACRO FIND 0 AND REPLACE WITH A MACRO FIND 0 AND REPLACE WITH A DISABLE 02010001010A 0B2010001010A SPECIAL KEY MAP F3 TO 0 SPECIAL KEY DISABLE F3 KEY MAPPING 0162048 0B162 SPECIAL KEY MAP KEYPAD ENTER TO 2 SPECIAL KEY DISABLE KEYPAD ENTER MAPPING 0182050 0B182 24 ...

Page 26: ...128 TERMINATION CHAR CR STRING 2 CODE 128 TERMINIATION CHAR LF 0202021080 0D 0202021090 0A STRING 2 CODE 128 TERMINATION CHAR CR LF STRING 2 CODE 128 TERMINATION CHAR REMOVED 0202021080 0D 0A 0B20202 STRING CODE 39 TERMINATION CHAR TAB STRING CODE 39 TERMINATION CHAR TAB REMOVED 0202001020 09 0B202001020 09 STRING ALL CODES PREAMBLE STX STRING ALL CODES POSTAMBLE ETX 0202002000 02 0202003000 03 25...

Page 27: ...Factory Default Setting 26 ...

Page 28: ...mmunication Default Terminal Type PC AT Keyboard US keyboard Terminator Enter Alpha numeric USB Communication Default Terminator type Enter Code mode Scan Code Keyboard US keyboard Decoder Selection Default EAN UPC Enable Code 39 Enable Code 32 Disable CODABAR Enable ITF 2 of 5 Enable MSI Disable Code 93 Enable Code 128 Enable EAN 128 Disable 27 ...

Page 29: ...Appendix A Troubleshooting Error Beeps 28 ...

Page 30: ...wer up signal Possible Cause Possible Solution There is no power from PC series port Use external power supply or take the power from PC c Problem When I connected RS232 interface reader to PC or terminal I got power up signal but no data transmitted Possible Cause Possible Solution This may cause by wrong pin out or wrong communication protocol Check the pin out and communication protocol to matc...

Page 31: ...nce e Problem Light comes on but symbol does not decode Possible Cause Possible Solution Scanner is not programmed for the correct bar code type Please refer User s Guide and be sure to select the correct interface selection and ensure that the scanner is programmed to read the type of barcode you are scanning Barcode symbol is unreadable Check the symbol to make sure it is not de faced Try scanni...

Page 32: ...etting of your computer g Problem Scanned data is incorrectly displayed on the host Possible Cause Possible Solution Scanner is not programmed to work with the host Be sure proper host type is selected For RS232 ensure the scanner s communication parameters match the host s settings For keyboard emulation configuration ensure the system is programmed for the correct keyboard type and that the CAPS...

Page 33: ...rd flickers when I read a bar code Possible Cause Possible Solution The Keyboard Country that you are using requires shifting in and out of the shift Lock mode to send the data properly This is normal operation You can reduce the flickering and speed the data transmit by sending numerics as keypad numerics or setting the keyboard country to UNIVERSAL mode 32 ...

Reviews: