DigiSense
DT Digital Detectors
All rights reserved. No part of this document may be
reproduced in any form without prior written permission
from the publisher.
Digi-412DTPT applicable countries (European version):
AT
BE
CY
CZ
DK
EE
FI
FR
DE
GR
HU
IE
IT
LV
LT
PT
LU
MT
NL
PL
SE
SL
ES
SK
GB
BG
RO
TR
CH
NO
Digi-412DTPT applicable countries (German Version):
AT, CZ, SL, DE, TR, RU, EE
© RISCO Group 10/2011
5IN1264 D
DigiSense FCC compliance Section (US version):
FCC Part 15 Note:
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
5HRULHQWRUUHORFDWHWKHUHFHLYLQJDQWHQQD
,QFUHDVHWKHVHSDUDWLRQEHWZHHQWKHHTXLSPHQWDQG
receiver.
&RQQHFWWKHHTXLSPHQWWRDQRXWOHWRQDFLUFXLWGLIIHUHQW
from that to which the receiver is connected.
&RQVXOWWKHGHDOHURUDQH[SHULHQFHGUDGLR79WHFKQLFLDQ
FCC Warning:
The manufacturer is not responsible for any radio or TV
LQWHUIHUHQFHFDXVHGE\XQDXWKRUL]HGPRGL¿FDWLRQVWRWKLV
HTXLSPHQW6XFKPRGL¿FDWLRQVFRXOGYRLGWKHXVHUV
authority to operate the equipment.
1
2
EN
FR
SP
IT
PR
PL
Wall mounting
Corner mounting
Montage mural
Montage en coin
Montaje en pared Montaje en rincón
Montaggio su parete piana Montaggio ad angolo
Montagem na parede Montagem no canto
0RFRZDQLXGRĞFLDQ\
0RFRZDQLXQDURĪQ\P
Terminal Wiring
EN
FR
SP
IT
PR
PL
TAMPER
ALARM
+
12VDC
-
Terminal Connection
12VDC: Power supply inputs
ALARM: NC Dry Contact switch
TAMPER: NC Dry Contact switch
Connexion
12VDC : alimentation électrique
$/$50FRQWDFWVHF1)GDODUPH
TAMPER : contact sec NF
GDXWRSURWHFWLRQ
Bornes de Conexión
12VDC: Entrada de alimentación
ALARM: Relé de Contacto Seco N.C.
TAMPER: Relé de Contacto Seco N.C.
Collegamento dei Morsetti
12VDC: Ingresso alimentazione
ALARM: Relè d’allarme NC libero da tensione
TAMPER: Relè di tamper NC libero da tensione
Terminais de Conexão
12VDC: Entrada de alimentação
ALARME: Relé de contato seco NF
TAMPER: Relé de contato seco NF
Pod
áą
c
]
enie
12VDC: Zasilanie czujki
ALARM: Zaciski alarmowe NC
7$03(5=DFLVNLVDERWDĪRZH1&
2
2
2
2
1
1
1
1
2
O N
DIP Switch & Jumper Settings
SW1-1: Pulse 1/2
ON
OFF
Important
1 pulse 2 pulses
EN
FR
SP
IT
PR
PL
For corridor and curtain
lens use only 1 pulse.
1 impulsion 2 impulsions Pour les lentilles rideau et
FRXORLUQXWLOLVH]TXXQHLPSXOVLRQ
1 pulso 2 pulsos
Para la lente de pasillo o cortina usar
sólo 1 pulso.
CHIUSO
APERTO
1 impulso 2 impulsi
Per le lenti a tenda o corridoio
utilizzare solo 1 impulso.
1 pulso 2 pulso
Para lente de corredor, use apenas
o pulso 1.
1 impuls 2 impulsów
:DĪQH'ODVRF]HZNLNRU\WDU]RZHML
NXUW\QRZHMOLF]QLNLPSXOVyZQDOHĪ\
XVWDZLüZSR]\FML21LPSXOV
SW1-2: LED ON/OFF
ON
OFF
LED Enable LED Disable
EN
FR
SP
IT
PR
PL
LED Activée LED Désactivée
LED Activado LED Desactivado
LED Attivato LED Disattivato
LED Ativado LED Desativado
/('$NW\ZQD/(':\áąF]RQD
Schematic of EOL Resistors
Sch
p
ma pour R
p
sistances EOL (r
p
sistances de
¿
n de ligne)
Esquema de Resistencias de Final de Línea
Schema di collegamento delle resisten
]
e EOL
Diagrama para resistor
¿
nal de linha
Re
]\
stor
\
parametr
\
c
]
ne (EOL)
No
Resistor
(Factor
\
Settings)
1K 2.2K 4.7K 5.6K 6.8K
J5 - TAMPER EOL JUMPERS
J6 - ALARM EOL JUMPERS
No
Resistor
(Factor
\
Settings)
1K 2.2K 4.7K 5.6K 6.8K
PANEL DEOL
ALARM
TAMPER
ALARM
TAMPER
EN
FR
SP
IT
PR
PL
Models: Digi-412DTPT
Mounting
2
1
4
3
5
Digi-412DTPT Wide Angle Lens
Top View
Clari
¿
cation
RTTE Compliance Statement
Risco Ltd. hereby declares that this equipment is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC. For the EC Declaration of Conformity please
referto our website: www.riscogroup.com
34k g
lb
PP
Side View
1
3
0
2
4
6
12
10
0
2
m
5
4
90°
2
4
6
0
2
4
6
2
4
6
10 12
0
m