Version 1.1 

Summary of Contents for ANOLIS Eminere Side 1

Page 1: ...Version 1 1 ...

Page 2: ... Fixture exterior view 4 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 3 3 The Booster box 9 3 4 The Booster box installation 12 4 Technical specifications 13 5 Cleaning and maintenance 19 5 1 Disposing of the product 19 6 ChangeLog 19 ...

Page 3: ...ing or installing Make sure the data power cable is not damaged by sharp edges Check the fixture and the power cord from time to time Do not install the unit near an open flame During operation the housing becomes hot Refer servicing to qualified service personnel This fixture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective earth...

Page 4: ...ck levels of possible interferences above the tested levels E1 E2 E3 given by this standard e g transmitters in surrounding area before installing the equipment Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B Please consider that unauthorized modifications on the fixture are forbidden due ...

Page 5: ...st be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The Eminere Side is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts Wiring of input output connectors Input panel connector Output panel co...

Page 6: ... control Do not connect disconnect Eminere Sides to the E box or Booster box and each other when they are under voltage When you change any setting of the E box disconnect the E box from power and connect it to power again to activate changes which you have made Examples of connection for various versions of the E box Please read the E box user manual for more information about its setting and con...

Page 7: ...Eminere Side 7 E box Pro E box Lite Number of connected Emineres Side to one E box output depends on a cable length power voltage type of and E box ...

Page 8: ... 159 191 20 m 83 131 159 191 30 m 58 131 159 191 50 m 35 88 128 186 70 m 25 63 92 133 100 m 17 44 64 93 200 m 9 22 32 47 EMINERE SIDE 2 Voltage Cable length 120V 190V 230V 277V 10 m 41 64 78 94 20 m 41 64 78 94 30 m 28 64 78 94 50 m 17 43 63 91 70 m 12 31 45 65 100 m 9 21 31 46 200 m 4 11 16 23 EMINERE SIDE 3 Voltage Cable length 120V 190V 230V 277V 10 m 28 44 53 64 20 m 28 44 53 64 30 m 19 44 53 ...

Page 9: ...ut The table below states max number of Emineres Side connected to the one LED output of the E box using Booster boxes which compensate a voltage drop regardless voltage and cable length 3 3 The Booster box To compensate a voltage drop in large installation the Booster boxes have to be connected in the chain of Emineres Side at every LED output of the E box The following tables give numbers of Emi...

Page 10: ...85 43 86 63 91 70 m 12 24 36 48 60 72 84 31 62 93 45 90 65 100 m 9 18 27 36 45 54 60 72 81 90 21 42 63 84 31 62 93 46 92 200 m 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 11 22 33 44 55 66 77 88 16 32 48 64 80 23 46 69 92 EMINERE SIDE 3 Max number of Emineres 3 64 Voltage Cable length 120V 190V 230V 277V 10 m 28 56 44 53 20 m 28 56 44 53 30 m 19 38 57 44 53 50 m 12 24 36 48 ...

Page 11: ...8 24 30 36 42 16 32 23 46 38 100 m 4 8 12 16 20 24 28 32 36 40 44 11 22 33 44 16 32 23 46 200 m 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 5 10 15 20 25 30 35 40 45 8 16 24 32 40 12 24 36 Example E box Daisy Power supply 230V Cable length 70m fixture Eminere Side 2 The Booster box has to be connected after every 45th Eminere Side 2 fixture 45 and fixture 90 from 94 fixtures ...

Page 12: ...lock 3 and two mounting holes of diameter of 4 6 mm 4 2 Screw the Booster box on a non flammable flat surface and connect cables The Cable gland M20x1 5 for Power IN 5 is intended for a cable of a diameter of 7 13mm Remove the end cap from the cable gland before passing the cable Power connection L N earth Core EU Braun Blue Green yellow Core US Black White Green We recommend to apply an adequate ...

Page 13: ...h power LEDs Eminere Side 4 48 x high power LEDs Colour variants RGBW RGBA single colour Beam Angle Symetrical 9 15 30 50 65 100 Bi symetrical 10 x 30 30 x 10 10 x 60 60 x 10 35 x 70 70 x 35 15 x 90 90 x 15 Wallwasher Wide Wallwasher Projected LED Life 60 000 Hrs L70 25 C77F Compatible drivers E box Daisy 1 Output 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel control 1px 1ft ...

Page 14: ...rating temperature 67 C Ambient 40 C 153 F Ambient 104 F Connection Input panel connector Amphenol ABAB DMQ06000021 IN P N13052952 Output panel connector Amphenol ABAB DAQ06000021 P N13052953 water tight cap Mounting method Via two L shape brackets LED module tilt adjustment range 95 95 Sizes Eminere Side 1 300mm 1ft Eminere Side 2 600mm 2ft Eminere Side 3 900mm 3ft Eminere Side 4 1200mm 4ft Housi...

Page 15: ...ere Side 15 Weight Eminere Side 1 2 5 kg 5 5 lbs Eminere Side 2 4 2 kg 9 3 lbs Eminere Side 3 5 9 kg 13 lbs Eminere Side 4 8 7 kg 19 1 lbs Dimensions All dimensions in mm inch Eminere Side 1 Eminere Side 2 ...

Page 16: ...Eminere Side 16 Eminere Side 3 Eminere Side 4 ...

Page 17: ...53007 Cable CE Leader FF 10m ABB1 DFQ06 P N 13053008 Cable CE Leader FF 25m ABB1 DFQ06 P N 13053009 Cable CE Leader FF 50m ABB1 DFQ06 P N 13053010 Cable US Leader FF 2m ABB1 DFQ06 P N 13053011 Cable US Leader FF 5m ABB1 DFQ06 P N 13053012 Cable US Leader FF 10m ABB1 DFQ06 P N 13053013 Cable US Leader FF 25m ABB1 DFQ06 P N 13053014 Cable US Leader FF 50m ABB1 DFQ06 P N 13053015 Cable CE Leader MM 2...

Page 18: ... MF 2m ABB1 DAQ06 P N 13053041 Cable US Leader MF 5m ABB1 DAQ06 P N 13053042 Cable US Leader MF 10m ABB1 DAQ06 P N 13053043 Cable US Leader MF 25m ABB1 DAQ06 P N 13053044 Cable US Leader MF 50m ABB1 DAQ06 Jumper cables P N 13053045 Cable CE Jumper FF FM 0 25m ABC1 DFQ06 P N 13053046 Cable CE Jumper FF FM 0 5m ABC1 DFQ06 P N 13053047 Cable CE Jumper FF FM 1m ABC1 DFQ06 P N 13053048 Cable CE Jumper ...

Page 19: ...ff loose dirt with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use ROBE OEM parts 5 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life...