background image

 

 

 

User Manual 

Universal Transmitter (TX) 

And Repeater 

 
 

 

 
 

 

A Division of TRAP INTERNATIONAL C.C.

  

Summary of Contents for Universal TX

Page 1: ...User Manual Universal Transmitter TX And Repeater A Division of TRAP INTERNATIONAL C C ...

Page 2: ...ls The input zone sends an intruder signal as soon as the input state is changed N C to N O or visa versa and will stop sending the supervisory auto test signal if it remains in the altered state hereby monitoring functionality of the devices wired to it Alternatively a Universal TX can be wired to a receiver and configured to be a repeater station for increased radio distance 400 meter radio rang...

Page 3: ...al this is important when installing multiple repeaters and will avoid possible signal clashing Delay Switch 1 Switch 2 Switch 3 2 4 SEC OFF OFF OFF 2 8 SEC OFF OFF ON 2 8 SEC OFF ON OFF 4 SEC OFF ON ON 4 8 SEC ON OFF OFF 5 SEC ON ON OFF 6 5 SEC ON ON ON Wiring Connect the Universal Transmitter to a 12 V power supply Wire the 12V ground and RXD of the Universal transmitter to a receiver SELECTING ...

Page 4: ...will be sent This will allow you to program the Roboguard into your appropriate decoder panel Tamper signals are required to programme Roboguards into decoder panels and will be sent when the relevant zone input is triggered NB When programming is complete turn Switch 2 off When mimicking Remote TX signals Switch 3 ON keep switch 2 off and program the input zones into remote TX zones of the decode...

Page 5: ...zones that are N O disconnected Turn Switch 4 on and off to programme The programme LED will flash the number of times on the chart below to confirm the desired zone input configuration Zone 1 2 3 4 1 flash N C N C N C N C 2 N O N C N C N C 3 N C N O N C N C 4 N O N O N C N C 5 N C N C N O N C 6 N O N C N O N C 7 N C N O N O N C 8 N O N O N O N C 9 N C N C N C N O 10 N O N C N C N O 11 N C N O N C...

Page 6: ... can now be tested by triggering the individual devices to confirming if they are working on the decoder panel The LED is used to indicate different settings and events In normal operation the LED will flash slowly for a repeater and fast when configured as a Universal TX When the Universal transmits the LED will flash faster for the duration of the transmition For a repeater the LED will go solid...

Page 7: ... on disconnection LED fast burst of flashing and the N O zones will do nothing as they are still N O By turning switch 4 on and off the Universal transmitter will learn the current state of the zones hence if a device is in the alternate i e N C switch being in an N O position state the wrong configurations re programmed as described on page 5 Trouble Shooting Notes ...

Page 8: ...s Dimensions 104 X 64 X 27 Weight 100 g Current consumption 5 2 mA Required Receiver U H F 433MHz Colour White Trap International CC PO BOX 38113 Point 4069 Durban South Africa sales roboguard co za www roboguard co za ...