background image

 

Roger Access Control System 

Apartment locks  

ADL-2 and ADL-2-BLE   

v1.0 

User Manual 

Firmware version: v1.0 

Document version: v1.0 Rev. B 

 

 

 

 

 

 

Summary of Contents for ADL-2

Page 1: ...Roger Access Control System Apartment locks ADL 2 and ADL 2 BLE v1 0 User Manual Firmware version v1 0 Document version v1 0 Rev B ...

Page 2: ...with start expiry date Automatic removal of previous identifiers when the newer one is used Option to disable selected identifiers Lock latch controlled with traditional lock cylinder Electronic lock can be opened with a metal key Exit from room by means of internal handle Access log in the internal memory Lock installed as replacement of traditional mechanical escutcheons and with original mortis...

Page 3: ... escutcheon with handle and it is dedicated to installation at the entry to controlled room The escutcheon includes keypad card reader A and hole for door cylinder which can be used for emergency door opening with metal key The electronic module which is located inside the escutcheon includes service pins B and connector C for programming cable Wires with plug D are used to connect external and in...

Page 4: ...ternal part of lock consists of escutcheon with handle and it is dedicated to installation at the exit from controlled room The internal escutcheon includes battery pack with cable and connector G which is used to connect supply to external part of lock E in fig 3 In order to replace batteries unscrew bolt to remove the cover ...

Page 5: ...n pressed then keypad backlight is on and finished with Alternatively PIN can be stored on proximity card by means of Roger MDM app and then the access can be granted by card reading at the lock In case of ADL 2 BLE the access can be also granted using smartphone with Roger Mobile Key app iOS Android installed Note ADL 2 locks support only MFC 4 Roger proximity cards ADL 2 locks can be operated in...

Page 6: ... 12 digits PIN includes expiry time and its start time precedes expiry time by 12 months Validity period is defined with 1 day resolution This PIN type enables to toggle office mode in the lock PIN Service PIN with 12 digits PIN includes expiry time and its start time precedes expiry time by 12 months Validity period is defined with 1 day resolution It is possible to define 16 PINs of this type wi...

Page 7: ...s PIN Master and PIN is the one which is supposed to be blocked Alternatively the PIN can be blocked with Roger MDM app in accordance with the section Programming and configuration List of blocked PINs Write the PIN on the card In order to write the pin on the card use the command 8 PIN where PIN is the code that is to be saved on the card and then put the proximity card against it Remove PIN from...

Page 8: ...memory of the lock is displayed Select on title bar to add new PIN and then enter 8 or 12 digits as well as enter name for the PIN Depending on selected option PIN is recorded in the app database and optionally it can be sent to lock e g for verification to unblock the door In case of ADL 2 BLE when PIN is clicked on the list then identification process is started via Bluetooth BLE radio communica...

Page 9: ...ent Menu with following icons and commands is displayed in title bar Icon Description Saves configuration in app database and uploads it to the lock if it is in Bluetooth BLE range Stores configuration in app database Additional options Synchronise clock Synchronizes lock clock with and app clock Restore default Restore default settings both in the app and lock Save PIN on card Saves up to 32 PINs...

Page 10: ... of blocked PINs The list includes all blocked PINs max 255 When list is full then the newest PIN replaces the oldest one Block Command enables to block particular PIN Remove outdated Command removes all blocked PINs which are outdated and cannot be used anymore for access granting Remove all Command removes all blocked PINs including ones which are not outdated and could possibly be used for acce...

Page 11: ... Lock installation Make holes in door using drilling template Lead battery wires fig 5 pos G through hole and then connect with wires from external part of lock fig 3 pos E Make sure that handle pin hole is positioned in such way that marker red dot indicates door top hinge fig 7 and then install handle pin inside the lock Install 4 x AAA batteries in the pack Mount escutcheon and verify the opera...

Page 12: ...t hand version normal or reverse bevel MFC 4 13 56 MHz MIFARE DESFire EV1 2K ISO size thin PVC proximity card Product history Product version Released Description 1 0 VI 2021 The first commercial version of the product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health ...

Reviews: