Roger Access Control System 

RWL-1 Wireless Lock 

Operating Manual 

Firmware version: 1.1 

 

Document version: Rev. F 

 

 

 

 

 
 

 
 

Summary of Contents for RWL-1 series

Page 1: ...Roger Access Control System RWL 1 Wireless Lock Operating Manual Firmware version 1 1 Document version Rev F ...

Page 2: ... is separated from the deadbolt and moves freely When the access is granted the electronic module couples the external handle with deadbolt and latch to enable door opening When the door is closed then the deadbolt is relocked automatically in order to protect door against unauthorized opening The RWL 1 lock can be optionally equipped with door cylinder and then be opened from the outside with tra...

Page 3: ...der G which can be used for emergency door opening with mechanical key The electronic module which is located inside the escutcheon includes service pins B and programming pins C Wires with larger plug D are used to connect the electronic module with mortise lock and wires with smaller plug E are used to connect the module with battery pack Two isolated wires F ended with heat shrinkable sleeve ar...

Page 4: ...the mortise lock In Online mode the status of knob is reported to access controller with KNOB SWITCH input which can be further configured in VISO management software In Offline mode the door can be locked with the knob switch and then it cannot be opened from the outside using proximity card When the handle is twisted then the knob reverts to normal position The internal escutcheon includes also ...

Page 5: ...rvomechanism controlled by electronic module External handle is coupled momentary whenever access is granted When the RWL 1 is operated in Office mode then external handle is coupled permanently Handle spacing i e distance from handle to cylinder in the mortise lock equals to 72mm Fig 6 Mortise lock Door cylinder RWL 1 lock is adapted to door cylinder installation Such cylinder enables emergency d...

Page 6: ... encrypted with own key in order to enable protection against card copying Due to relatively easy copying of the card serial numbers CSN it is recommended to configure the lock for operation with programmable card numbers PCN Offline mode In the Offline mode the lock grants access for cards stored in its memory The lock can operate permanently in Offline mode or enter this mode temporary when wire...

Page 7: ...ess connection is lost If the Emergency mode is not configured in RACS 5 AIR system then there is a risk that mentioned disturbances will affect the system and hinder its operation Radio channels The wireless communication utilizes the IEEE 802 15 4 2 4GHz band which is shared with Wi Fi networks If the lock uses the same channel as Wi Fi network then in case of intensive Wi Fi transmission the lo...

Page 8: ...mode user list and can grant the access according to the description given in section Offline mode The card can be granted access if it is stored on any of two mentioned user lists LED indicators RWL 1 lock is equipped with 4 LED indicators which functions are described in the table below LED indicators Name Colour Description LED RED Red Online mode the function of this LED is programmed in VISO ...

Page 9: ...DD ADD programming card New card adding to the lock DEL DEL programming card Card deleting from the lock Configuration recovery from the lock In some circumstances it might be required to recover the configuration settings from the lock Such operation can be done by means of RogerVDM software Regardless of the operating mode it is not possible to recover communication password and card encryption ...

Page 10: ...d to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards programming Example Programming of user with Normal access and Office access Read ADD programming card thrice Read first card to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are ...

Page 11: ...e LED SYSTEM shall pulsate 4 In RogerVDM select Device New and then select type of device RWL 1 and serial COM port with RUD 1 interface 5 Select required settings 6 Make backup by saving settings to file button Send to File 7 Upload settings to the lock button Send to device 8 In RogerVDM select Device Disconnect 9 Remove jumper from MEM pins 10 Short RST pins for a moment preferably by placing a...

Page 12: ...on LED SYSTEM Default value Yes Short sound after card read When option is set then card reading is confirmed with short acoustic beep Default value Yes LED SYSTEM pulsing when card close to the reader When option is set then orange LED SYSTEM pulses whenever card is detected near the reader Default value No Battery low level signalisation When option is set then lock signals low battery level by ...

Page 13: ...d automatically when the network is defined Default value Auto Notification time s The parameter defines how often the lock shall wake from standby mode and shall communicate with hub to confirm its availability in the network The shorter is the notification time the more often communication is established and batteries are discharged quicker Default value 60s Registration time s The parameter def...

Page 14: ...sents output which controls LED RED Default value LED red LED GREEN comment Any text to be displayed in VISO management software in order to facilitate object identification LED GREEN object represents output which controls LED GREEN Default value LED green LED SYSTEM comment Any text to be displayed in VISO management software in order to facilitate object identification LED SYSTEM object represe...

Page 15: ...the card s memory Default value BIN First byte position FBP The parameter specifies the position of the most significant byte MSB of programmable card number PCN Default value 0 Last byte position LBP The parameter specifies the position of the least significant byte LSB of programmable card number PCN Default value 7 Sector ID The parameter specifies sector number in card s memory where programma...

Page 16: ...ment preferably by placing and removing jumper When acoustic signalization is started place jumper on MEM pins and the devices shall confirm memory reset with 2 acoustics beeps Read any proximity card and it shall be new ADD programming card Read any proximity card and it shall be new DEL programming card Wait for 3 acoustic beeps The lock shall restore default factory settings and shall switch to...

Page 17: ...o EN 50131 1 Class I indoor general conditions temperature 5 C to 40 C relative humidity 10 to 95 no condensation IP code IP40 Dimensions 78 x 242mm Weight Approx 2200g Certificates CE Ordering information Product Description RWH 1 RACS 5 AIR wireless hub RWL 1 LI Wireless door lock with escutcheons left hand RWL 1 RI Wireless door lock with escutcheons right hand RWL 1 LO Wireless door lock with ...

Page 18: ...lectric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp z o o sp k 82 400 Sztum Gościszewo ...