background image

 

WALLPOD: EV COMMERCIAL 

CHARGE SUPERFAST 

 

 

 

 

Doc No.: EVWPI-003 Rev: 01 

This instruction is applicable to the following EV Commercial Charge Superfast range of products: 
EVWP2096, EVWP2156, EVWP2036, EVWP2046, EVWP2056 & EVWP2066. 

INSTALLATION INSTRUCTIONS 

NOTE: WallPods must always be installed on a flat and smooth surface. When installing a Wallpod 
always remove the unit from the wall before drilling to avoid any brick dust contaminating the 
internal components. 

 
All installation work is to be carried out by a competent and suitably qualified engineer. 

1. 

Establish a suitable mounting location for the WallPod that is both secure and environmentally safe. 

2. 

Carefully remove the WallPod from its packaging and check that it is undamaged. 

3. 

Open the front of the unit by unscrewing the six screws that secure the front cover to the base (retain 
the screws). 

4. 

Drill out the four oval shaped mounting points, located at the rear of the base unit. 

5. 

Cut a suitably sized hole in the base unit to receive the supply cable. 

6. 

Whilst  supporting  the  front  of  the  unit,  carefully  place  the  base  unit  in  the  desired  location  and  mark 
the four fixing points. 

7. 

Remove the WallPod from the wall and drill the wall to receive the fasteners. 

8. 

Using the four fixing points and suitable fasteners, screw the base unit into position. 

9. 

Using an appropriate and water resistant method of cable entry into the unit, connect the supply cable 
to the 3 Phase, Neutral and Earth terminals. 

10. 

For models EVWP2056 & EVWP2066 fit the supplied switchgear at source in compliance with current 
regulations and then connect to the appropriate terminals within the WallPod. 

11. 

Switch on the overload/fault current device(s). 

12. 

Refit and secure the front cover, ensuring no cables are trapped beneath it. 

13. 

Switch on the power to the unit and test in accordance with current regional electrical regulations.  

14. 

Secure the IP65 cover. 

OPERATING INSTRUCTIONS 

Status Indicator Guide 

 

Flashing blue light - Ready for Charge (IEC socket only) 

 

Fixed blue light - Cable plugged in but not charging 

 

Fixed green light - Charging in progress 

 

Flashing red light - Fault indicated - Switch off unit at source and switch back on after 20 secs to 
clear fault. If fault persists, contact your installer 

 
 

 

Reviews: