background image

Intense, Oracle, 

Reveal Illuminated Mirror

Installation & aftercare instructions

Please retain for future reference

INTENSE MLE500

ORACLE MLE510

REVEAL MLE520

REF:  AR.RR.MLE500.510.520|  2.14 V1.00

Customer Services, Roper Rhodes Ltd, Brassmill Lane Trading Estate, Bath, BA1 3JF 

Tel: 01225 303 900    

|

    Fax: 01225 448 877    

|

    Email: sales@roperrhodes.co.uk    

|

    Web: www.roperrhodes.co.uk

ELECTRICAL SAFETY INSTRUCTIONS

 (Applicable to UK Installations only)

All fittings must be installed by a competent person, in accordance with current IEE wiring 

regulations.  If in doubt consult a qualified electrician

IMPORTANT

Always switch off the electrical supply at the mains during installation and maintenance.  It 

is recommended that the fuse is withdrawn or the circuit breaker is switched off for the 

necessary circuit before installation commences.

Fitting in Bathrooms is subject to the appropriate zone in accordance with IEE Regulations.  

This product is suitable for zone 2 and outside zones.  IT IS NOT suitable for installation in 

Zone 0 or Zone 1. It is also not suitable for installation in saunas, steam rooms or shower 

cubicles.  This product is only suitable for permanent installation.  DO NOT connect to a 

trailing plug and socket outlet.  Although this product has an Ingress Protection rating of 

IP44 it is only suitable for indoor use.  Do not attach the product to surfaces that are damp or 

otherwise electrically conductive.

INSTALLATION CARE & SAFETY

Wear suitable eye protection when drilling.  Take care when using power tools near water - 

the use of a residual current device (RCD) is advised.  Beware of hidden cables or pipes.  

Take care if drilling on tiled surfaces in case the drill slips.  A piece of masking tape applied 

to the wall before marking out the fixing holes will stop the drill from wandering.

IMPORTANT

The product must be installed with a minimum distance of 150mm between the infrared 

sensor and an adjacent wall or obstruction to ensure correct function of the sensor (see 

diagram below).

DO NOT strike glass components with hard or pointed items.  DO NOT place very hot or very 

cold items against or in close proximity to glass surfaces unless an adequately thick 

insulation material is used to prevent such items coming in contact with the glass.  

The nominal thickness of the mirror glass used in this product is 5mm and is film backed for 

safety.  If the glass becomes chipped or broken replace immediately.

This product should be positioned well away from curtains and other fabrics. Never cover 

the mirror. This product is heated, we recommend that it is turned off after use and should 

never be left on for prolonged periods of time 

This  product  could  be  dangerous  and  is  only  to  be  installed  by  a  competent  person.

CLEANING

It is recommended that the unit is cleaned with a soft, dry, non abrasive cloth when turned 

off.  Never use cleaning agents or abrasive materials on any type of surface finish.  Do not 

allow moisture to come into contact with the electrical components.

COMPLIANCE

This product complies with all relevant British and European safety standards:

WIRING

This product is manufactured to class I category and must have an earth connection.

COLOUR CODING:

L    - Live 

= Brown

N   - Neutral  = Blue

      - Earth  = Green & Yellow

LIGHTS

.

To obtain a replacement LED lamp if faulty or broken contact customer services (see details 

at foot of page) quoting product code.

2

2

2

OUTSIDE

ZONES

2

ZONE

1

0.75m

2.25m

3.0m

0.6m

0.6m

0.75m

Bathroom Zones Diagram

Distances from a bath tub or shower tray

Reviews: