background image

ENGINEERING STANDARDS

Rosedale Products, Inc.

Issue Date: 25MAR96

3730 West Liberty Road

Revision: C

Ann Arbor, MI 48103

Revision Date: 30May2003

IOM

7_4_3 Model LCO-8

125.wpd

n:\iom\

Specification No.

7.4.3

PAGE:  1 of 6 

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Rosedale Engineering Standards are the property of Rosedale Products, Inc.  A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

Products, Inc.) to any individual or firm beyond the intended recipient firm or individual.  Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or

future employment, or removal from Rosedale’s "Approved Manufacturers and Specialty Contractors List".

MODEL

LCO-8

INSTALLATION, OPERATION AND

MAINTENANCE MANUAL

ROSEDALE PRODUCTS, INC.

MODEL LCO-8

125 PSIG RATED FILTER UNIT

Table of Contents

I.

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

II.

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

III.

Spare Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

IV.

Spare Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Summary of Contents for LCO-8

Page 1: ... not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufacturers and Specialty Contractors List MODEL LCO 8 INSTALLATION OPERATION AND MAINTENAN...

Page 2: ... MODEL LCO 8 is designed to utilize either the side NPT coupling as an outlet or the bottom NPT coupling as an outlet depending upon your application requirement Simply install the NPT plug to direct flow as needed There are two 1 4 NPT ports on the shell of the MODEL LCO 8 Filter unit These ports can remain plugged or used for pressure gauges or special fittings as your application requires Some ...

Page 3: ...l completely open Complete opening of inlet service line until desired flow rate is reached Once the desired service flow has been established the filter will operate efficiently until dirty However under no circumstances should more than 15 PSI Differential Pressure through the filter be obtained Operating the filter unit with a high differential may cause filter bags to rupture and or cause dama...

Page 4: ...e bag basket making sure filter bag ring is firmly seated against the top of the basket flange For best results be sure filter bag is installed fully extended to the bottom of the basket 9 Inspect cover gasket for cuts or other signs of failure and make sure it is properly seated Your Rosedale MODEL LCO 8 Filter unit is now ready for operation Refer to filter system start up procedure III Spare Pa...

Page 5: ...ing Standards are the property of Rosedale Products Inc A Rosedale standard or copy thereof shall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Appro...

Page 6: ...ww rosedaleproducts com Important Notice Warranty In the event any Rosedale Products Inc filtration product is found to be defective in material workmanship or not in conformance with any express warranty for a specific purpose Rosedale s only obligation and your exclusive remedy shall be to repair replace or refund the purchase price of such parts or products upon timely notification thereof and ...

Reviews: