background image

Installation Instruction 

 

for 

½”

 annular corrugation cable 

MA_1C7-C03_U

 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG 
P.O.Box 1260 

D-84526 Tittmoning 

Germany 

www.rosenberger.de 

Tel. 

: +49 8684 18-0 

Email  : info@rosenberger.de 

Page 

 

1 / 2 

 

RF_35/0

6.10/1.0

 

Dieses Dokument ist urheberrec

htlich geschützt ● 

T

his document 

is protected by cop

yright ● Rosenbe

rger H

ochfreque

nztechnik Gmb

& Co. KG 

 

 

60S1C7-C03 

 

60K1C7-C03 

 

53S1C7-C03 

 

53K1C7-C03 

64S1C7-C03

 

64K1C7-C03

 

 

 

 

Torque Wrench  

 acc. to series

 

A) 

 

SLZ0002-000

 
 
 
 

SLT001-C03 

  Cut your cable with tool of picture A) 

  Straighten the first 200mm of the cable.

 

 

SLZ0009-000 
SLZ0009-001 
SLZ0009-003

 

1)  Insert the cable into the jacket stripping 

tool and remove about 20 mm of the 
cable jacket. 

2)  Insert the cable into the jacket cutter, 

annular nose in cable groove and cut 
the jacket and cable outer conductor.

3)  Remove cable jacket until the mark 

done by the jacket blade. 

4)  Control the cut surfaces 

5)  Remove the cable outer conductor and 

dielectric.  Tool:  99W057-000 
 

 

 

-001 

6)  If needed, clean the cable inner 

conductor with stripper, avoid any 
damages, scratches on the inner 
contact. Tool: SLT004-000

7)  mark inner conductor by means of 

gauge :  SLT009-000 

8)  cut the inner conductor at the marked 

position.  Tool:  99W057-003 

9) 

Sharpen the inner conductor of the 
cable with the striping tool. 