Installation Instruction
for
½”
annular corrugation cable
MA_1C7-C03_U
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.
: +49 8684 18-0
Email : info@rosenberger.de
Page
1 / 2
RF_35/0
6.10/1.0
Dieses Dokument ist urheberrec
htlich geschützt ●
T
his document
is protected by cop
yright ● Rosenbe
rger H
ochfreque
nztechnik Gmb
H
& Co. KG
60S1C7-C03
60K1C7-C03
53S1C7-C03
53K1C7-C03
64S1C7-C03
64K1C7-C03
Torque Wrench
acc. to series
A)
SLZ0002-000
SLT001-C03
Cut your cable with tool of picture A)
Straighten the first 200mm of the cable.
SLZ0009-000
SLZ0009-001
SLZ0009-003
1) Insert the cable into the jacket stripping
tool and remove about 20 mm of the
cable jacket.
2) Insert the cable into the jacket cutter,
annular nose in cable groove and cut
the jacket and cable outer conductor.
3) Remove cable jacket until the mark
done by the jacket blade.
4) Control the cut surfaces
5) Remove the cable outer conductor and
dielectric. Tool: 99W057-000
-001
6) If needed, clean the cable inner
conductor with stripper, avoid any
damages, scratches on the inner
contact. Tool: SLT004-000
7) mark inner conductor by means of
gauge : SLT009-000
8) cut the inner conductor at the marked
position. Tool: 99W057-003
9)
Sharpen the inner conductor of the
cable with the striping tool.