Page 1: ...AC B C D3x Family Standalone Access Control Units Installation and Programming Manual AC B3x AC C3x AC D3x ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ...1 Mounting 12 3 2 Wiring 14 3 2 1 AC B3x 15 3 2 2 AC C3x 16 3 2 3 AC D3x 17 4 Normal Secure and Master Users 18 5 Modes of Operation 19 6 Changing the Modes of Operation 20 6 1 Changing from Normal to Secure Mode 20 6 2 Changing from Secure to Normal Mode 20 6 3 Changing from Normal to Bypass Mode 21 6 4 Changing from Bypass Mode to Normal Mode 21 7 REX Button 22 8 Case and Back Tampers 23 9 BL D4...

Page 4: ...10 9 Enrolling Primary and Secondary Codes 31 10 9 1 Primary Codes 31 10 9 2 Secondary Codes 32 10 9 3 Enrolling Primary and Secondary Codes 32 10 9 4 Enrolling Primary and Secondary Codes Using the Standard Method 32 10 9 5 Enrolling Secondary Codes Using the Code Search Method 34 10 10 Deleting Primary and Secondary Codes 35 10 10 1 Deleting Primary and Secondary Codes Using the Standard Method ...

Page 5: ... 13 Figure 5 AC C3x Mounting Holes and Terminal Blocks 14 Figure 6 AC D3x Mounting Holes and Terminal Blocks 14 Figure 7 AC B3x Wiring the Lock Strike Relay and REX 15 Figure 8 AC B3x Wiring the BL D40 External Sounder 15 Figure 9 AC C3x Wiring the Lock Strike Relay and REX 16 Figure 10 AC C3x Wiring the BL D40 External Sounder 16 Figure 11 AC D3x Wiring the Lock Strike Relay and REX 17 Figure 12 ...

Page 6: ...List of Tables vi AC B C D3x Family Installation and Programming Manual List of Tables Table 1 Programming Menu 25 ...

Page 7: ...g future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained ...

Page 8: ...dard AC C31 2X6 Mullion AC C32 2X6 Mullion AC D31 3X4 Standard AC D32 3X4 Standard 1 2 Key Features The following are some of the AC B C D3x key features Built in proximity card reader 125 kHz ASK Modulation AC x32 models Built in keypad for PIN code entry Internal buzzer Comes with security screw and security screw tool Two status programming interface LEDs Three user levels Normal User Secure Us...

Page 9: ...ession diode 1N4004 1 3 Equipment The following equipment is provided in every AC B C D3x package AC B C D3x controller Installation kit Installation and operating instructions 1 4 Additional Equipment The following additional equipment is required Electric Lock Strike Mechanism Fail Safe Power to Lock or Fail Secure Power to Open Power supply with backup battery 12 to 16 VDC from a regulated powe...

Page 10: ... mA Relay Outputs Lock Strike Relay Electronic 3 5 A with built in suppressor protection Auxiliary Relay Form C 1 A AC x32 models Inputs REX N O Dry Contact Auxiliary Input In Monitor Monitor Mode N C Dry Contact Input Mode N O Dry Contact LEDs Two tri colored LEDs Built In Proximity Reader AC x32 models Read Range 90 mm 3 5 in Modulation ASK at 125 kHz Compatible cards All 26 Bit EM cards Measure...

Page 11: ...ge 31 C to 63 C 25 F to 145 F Operating Humidity Range 0 to 95 non condensing Mechanical Characteristics Dimensions Length x Width x Depth AC B3x 92 x 92 x 24 mm 3 6 x 3 6 x 0 9 in AC C3x 130 x 42 x 18 mm 5 1 x 1 7 x 0 7 in AC D3x 122 x 75 x 24 mm 4 8 x 3 0 x 0 9 in Weight AC B3x 124 g 4 4 oz AC C3x 55 g 1 9 oz AC D3x 115 g 4 1 oz ...

Page 12: ...ce use a plastic spacer when mounting the reader 3 1 Mounting Before starting select the location to mount the controller This location should be at shoulder height and on the same side as the door handle The AC B C D3x is designed to be easily mounted onto a US Gang Box To mount the controller 1 Remove the bezel screw from the bottom of the unit see Figure 1 Figure 2 and Figure 3 Figure 1 AC B3x ...

Page 13: ...ogramming Manual 13 Figure 2 AC C3x Labeled Diagram Figure 3 AC D3x Labeled Diagram 2 Screw the controller onto a US Gang Box through the two mounting holes provided see Figure 4 Figure 5 and Figure 6 Figure 4 AC B3x Mounting Holes and Terminal Blocks ...

Page 14: ...3 2 4 Replace the controller s bezel and replace the factory default screw with the security screw that is provided in the installation kit A security screw tool is also provided in the installation kit 3 2 Wiring Typical wiring diagrams for the various units are shown in the following subsections For other wiring diagram examples refer to the support section of the Rosslare website http www rossl...

Page 15: ...Installation AC B C D3x Family Installation and Programming Manual 15 3 2 1 AC B3x Figure 7 AC B3x Wiring the Lock Strike Relay and REX Figure 8 AC B3x Wiring the BL D40 External Sounder ...

Page 16: ...Installation 16 AC B C D3x Family Installation and Programming Manual 3 2 2 AC C3x Figure 9 AC C3x Wiring the Lock Strike Relay and REX Figure 10 AC C3x Wiring the BL D40 External Sounder ...

Page 17: ...Installation AC B C D3x Family Installation and Programming Manual 17 3 2 3 AC D3x Figure 11 AC D3x Wiring the Lock Strike Relay and REX Figure 12 AC D3x Wiring the BL D40 External Sounder ...

Page 18: ...grants access in its three modes of operation There are three user levels Normal User A Normal User only has a Primary Code and is only granted access when the unit is in Normal or Bypass mode Secure User A Secure User must have a Primary and Secondary Code programmed the two codes cannot be the same The Secure User can gain access when the unit is in any of its three modes of operation In Normal ...

Page 19: ...trike Relay is programmed for Fail Safe Operation or for Fail Secure Operation When the Lock Strike Relay is programmed for Fail Secure Operation the door is locked until the door bell button is pressed When the Lock Strike Relay is programmed for Fail Safe Operation the door is constantly unlocked Secure mode Mode LED is red Only Secure and Master Users can access the premises during the Secure M...

Page 20: ...ure mode 1 Enter the 4 digit Normal Secure code The Mode LED flashes red 2 Press to confirm the mode change The Mode LED turns red 6 2 Changing from Secure to Normal Mode The default factory setting for the Normal Secure Code is 3838 To change from Secure to Normal mode 1 Enter the 4 digit Normal Secure code The Mode LED flashes green 2 Press to confirm the mode change The Mode LED turns green Mod...

Page 21: ...it Normal Bypass Code The Mode LED flashes orange 2 Press to confirm the mode change The Mode LED turns orange 6 4 Changing from Bypass Mode to Normal Mode See Section 10 6 to create modify the Normal Bypass Code To change from Bypass to Normal mode 1 Enter the 4 digit Normal Bypass code The Mode LED flashes green 2 Press to confirm the mode change The Mode LED turns orange Mode Door Orange Mode D...

Page 22: ...ail Safe Operation or for Fail Secure Operation The door chime in the BL D40 does not sound when the REX button is used to open the door Fail Secure Operation From the moment the REX button is pressed the door remains unlocked until the Lock Strike Release Time passes After this time the door is locked even if the REX Button is not released Fail Safe Operation From the moment the REX Button is pre...

Page 23: ...der PS x41 Series Power Supply or PS x42 Series Power Supply receives a Tamper Event Signal it activates a siren and if available a strobe light The siren time can be easily programmed in the unit from 0 to 9 minutes You can clear a tamper event by entering a valid User or Open code to open the Lock Strike Output in the current mode of operation For example while in Secure mode you cannot use the ...

Page 24: ...The bell always sounds when the controller s doorbell button is pressed The door chime can be programmed to sound whenever the controller unlocks the door the door chime does not sound when the REX button is used to open the door The siren can be programmed to sound when the case of the controller is opened or when the controller is removed from the wall The controller can also program the length ...

Page 25: ... unit s menus It also shows all the default factory codes and settings Table 1 Programming Menu Menu Number Menu Description Factory Settings 1 Change Open Code 1 2580 2 Change Open Code 2 0852 3 Change Program Code 1234 4 Change Normal Secure Code 3838 5 Change Normal Bypass Code N A 6 Change Door Release Time 0004 7 Enroll PIN code proximity cards AC x32 models or both 8 Delete PIN code or proxi...

Page 26: ...Programming code is valid the door LED turns green and the unit enters Programming mode The controller must be in Normal mode to enter the Programming mode The factory default Programming code is 1234 If a Programming code is not entered within five seconds the unit returns to Normal mode 10 2 Exiting Programming Mode To exit Programming mode 1 Press for two seconds Three beeps are emitted The Doo...

Page 27: ... the Lock Strike Relay during installation The default factory setting for Open Code 1 is 2580 When the first user is added to the controller the default Open Code 1 is automatically deleted and is ready for a new Open Code 1 to be re entered To change the Open Code 1 1 Enter Programming mode 2 Press 1 to enter Menu 1 The Mode LED turns red 3 Enter the new 4 digit code that you want to set as Open...

Page 28: ...Programming mode 2 Press 2 to enter Menu 2 The Mode LED turns orange 3 Enter the new 4 digit code that you want to set as Open Code 2 Three beeps are emitted The system returns to Normal mode Open Code 2 does not function in Secure mode Wrong entries return the controller to Normal mode Code 0000 erases and deactivates the Open code 10 5 Changing the Programming Code To change the Programming code...

Page 29: ...LED flashes red 3 Enter the new 4 digit code that you want to set as the Normal Secure code Three beeps are emitted The system returns to Normal mode When the Auxiliary Mode is 1 2 3 or 4 the Auxiliary Input takes priority over the Normal Secure Code 10 7 Changing the Normal Bypass Code and Door Chime Settings The Normal Bypass code is also used to turn the door chime off and on To change the Norm...

Page 30: ...ypass Code and disable the door chime Enter any code ending with 0 Enable Bypass Code and enable the door chime Enter a code not ending with 0 Three beeps are emitted The system returns to Normal mode The door is only generated when the Lock Strike Relay is activated due to a valid code entry 10 8 Setting Fail Safe Secure Operation Tamper Siren Time and Lock Strike Release Time 1 Enter Programming...

Page 31: ...0512 means a Fail Secure Operation consisting of a 5 minute siren and a 12 second Lock Strike release time Three beeps are emitted The system returns to Normal mode 10 9 Enrolling Primary and Secondary Codes 10 9 1 Primary Codes Primary Codes can only be enrolled to an empty user slot meaning a slot where there is no existing Primary code Primary Codes must be unique meaning that one user s Primar...

Page 32: ... Codes There are two methods to enroll Primary and Secondary codes Standard Method Mainly used when the user slot number for the user that you want to program is known You can program both Primary and Secondary codes using the Standard method see Section 10 9 4 Code Search Method Mainly used when enrolling a user s Secondary code and the User slot code is unknown The Code Search method only works ...

Page 33: ... the controller is ready to accept a Secondary Code If the selected slot already has a Primary and Secondary Code you hear a long beep and the controller returns to Normal mode b Present a proximity card AC x32 models or enter the 4 digit PIN that you want to assign as the Primary or Secondary Code for this slot number If the proximity card presented or PIN entered is valid the Mode LED stops flas...

Page 34: ...m you want to add a Secondary Code 4 Present a proximity card AC x32 models or enter the 4 digit PIN code of the Primary code belonging to the user for whom you want to add a Secondary code 5 The Mode LED flashes red If the Primary code entered is not valid a long beep is emitted and the unit continues to wait for a valid Primary code 6 Present a proximity card AC x32 models or enter the 4 digit P...

Page 35: ...d 1 Enter Programming mode 2 Press 8 to enter Menu 8 The Mode LED turns orange and the Mode LED turns red 3 Enter the 3 digit user slot code you wish to delete The Mode LED flashes red indicating the controller is waiting for the Programming code to confirm the deletion If the user slot is empty a long beep is emitted and the unit returns to Normal mode 4 Enter your programming code to confirm the...

Page 36: ...d 3 Enter 000 as the 3 digit user slot number The Door LED flashes orange indicating that the controller is now waiting for the Primary code of the user you want to delete The controller is now waiting for the Primary Code of the user you want to delete 4 Enter the 4 to 8 digit PIN code of the Primary Code belonging to the user you want to delete The Mode LED flashes red 5 Enter your Programming c...

Page 37: ...de 2 Press 0 to enter Menu 0 The Mode LED and the Door LED flash red 3 Enter your 4 digit Programming code If the Programming Code is valid all memory is erased three beeps are emitted and the controller returns to Normal mode If the Programming code is invalid a long beep is emitted and the controller returns to Normal mode without erasing the memory of the controller 10 12 Replacing a Lost Progr...

Page 38: ...ing a Lost Normal Secure Code To be able to replace lost Normal Secure code the controller must be in Secure mode Before proceeding verify that the Mode LED is red 1 Remove power from the unit 2 Press the REX button 3 Apply power to the unit while pressing the REX button 4 Release the REX button 5 You have 15 seconds to program a new Normal Secure code into the unit using the initial default code ...

Page 39: ...al 39 A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 40: ...security com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electronics Ind...