AY-H6255BT
CSN SMART™ Smart Card Readers (Rev. A)
Installation and User Manual
1
1.
Introduction
The CSN SMART™ AY-H6255BT is an innovative reader that lets
cardholders use smartphone apps as credentials in access control
systems by BLE ID and NFC ID compatible apps. The unit features three
technologies: a built-in CSN smart card (13.56 MHz) reader, an NFC ID
reader, and a Bluetooth BLE ID reader mode that supports BLE ID
transmitted by both Android and iOS smartphone apps.
The following list shows the credential technologies for which we have
confirmed compatibility:
ISO14443A – MIFARE® Ultralight® Nano / EV1/ C, MIFARE
Classic® / Classic EV1, MIFARE Plus® S / SE / X / EV1, MIFARE
DESFire® EV1 / EV2, N-TAG NFC / Card Emulation
ISO15693 – HID® iClass®, PicoPass, iCode, LEGIC
ISO18092 – SONY® FeliCa® (Hong Kong Octopus)
Rosslare’s CS-ECA NFC app (HCE) for Android smartphones
Scan the QR code to download Rosslare’s NFC app.
Android app and BLE ID for Android and iPhone
This list is continuously updated. For the latest compatibility list,
contact your sales representative
The standard reader outputs the Wiegand CSN data in Wiegand 26-Bit
format. Other Wiegand formats are selectable using the
CS-CCT
Configuration Card Tool for the DR-6255 application.
1.1
Installation Kit
The installation kit consists of the following items to be used during
the installation procedure:
1 self-adhesive mounting label template
2 mounting screws and 2 screw anchors
1 Torx key tool
1 Torx security screw
Figure 1: AY-H6255BT
2.
Technical Specifications
2.1
Electrical Characteristics
Power Supply Type
Regulated
Operating Voltage Range
8 to 16 VDC
Current @ 12 V
Standby: 110 mA, max: 185 mA
Bluetooth BLE Read Range
From 1 m to 10 m (3.2 to 32.5 ft) (line of sight)
RFID and NFC Read
Range*
5 cm to 10 m (2.0 to 3.9 in.)
LED/Buzzer Controls
Dry Contact, N.O.
Tamper Output
Open collector, active low, max. sink current
16 mA
Maximum Cable Distance
to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2
18-AWG twisted shielded cable
* Measured using a Rosslare MIFARE Classic EV1 (ISO card). Read range with
other credential technologies may vary. Range also depends on electrical
environment and proximity to metal.
2.2
Environmental Characteristics
Operating Temp. Range
-35°C to 66°C (-31°F to 150°F)
Operating Humidity Range
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, UV-resistant, meets IP65,
epoxy-potted, suitable for indoor and outdoor
use
2.3
Physical Characteristics
Dimensions
(H x W x D)
110.7 x 75.0 x 17.0 mm (
4.4 x 3.0 x 0.7
in.)
Weight
177 g (6.2 oz)
3.
Wiring
The units are supplied with a 10-conductor 5-m (16-ft) pigtail with
exposed wires coated with solder.
To connect the reader to the controller:
1.
Select the appropriate connections according to Table 1.
2.
Prepare the controller cable by cutting its jacket back about 3 cm
(1¼") and strip the insulation from the wires about 1.3 cm (½").
3.
Splice the reader’s pigtail wires to the corresponding controller
wires and cover each joint with insulating tape.
4.
If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
5.
Trim and insulate the ends of all unused conductors individually.
Do not short any unused wires together.
•
The individual wires from the reader are color coded according the
Wiegand standard.
•
When using a separate power supply for the reader, this supply and
that of the controller must have a common ground.
•
The reader’s cable shield wire should be preferably attached to an
earth ground, or a signal ground connection at the panel, or power
supply end of the cable.
Table 1: Wiring
Wire Color
Function
Red
Power
Black
Ground
Green
Data 0 / Data
White
Data 1 / Clock
Orange
Green LED Control*
Brown
Red LED Control*
Purple
Tamper Output
Yellow
Buzzer Control*
Blue
RS-485 – A / OSDP**
Gray
RS-485 – B / OSDP**
* These wires have programmable functions that may be adjusted by presenting
a configuration card within 10 seconds upon powering on the unit. See the
CS-CCT Configuration Card Tool for the DR-6255 Software Manual
for how
you can create a configuration card.
** RS-485 is used for firmware update.