1.

 

General Description 

The AY-Q12 Prox Reader is a weather-resistant and 
vandal-resistant RFID proximity card reader, to be 
installed for use with access control systems.  
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

2.

 

Technical Specifications 

2.1.

 

Electrical Characteristics 

Power supply:  Linear type recommended 
Operating Voltage Range: 5-16 VDC 
Tamper Output: 
Open collector, active low, max. sink 
current is 16 mA 
RF modulation: ASK 
Output modulation: 26-bit Wiegand 
Maximum Input Current 
Standby - 35 mA; Read - 100 mA 
Regulatory Approvals: USA UL294 & FCC Part 15B; Europe 
CE Listed 

2.2.

 

Environmental Characteristics 

Operating Temperature: -31°C to +63°C (-25°F to +145°F) 

Operating Humidity: 0% to 95% non-condensing  
Usage
: Indoor and outdoor use 
Card read distance: 
55 mm (2")measured using Rosslare 
Proximity Card (P/N AT-11/14) or equivalent. Range also 
depends on electrical environment and/or proximity to 
metal. 

2.3.

 

Physical Characteristics 

Dimensions: 120 mm (L) x 76 mm (W) x 27 mm (D) (4.72" x 3" 
x 1") 
Maximum cable distance to Controller: 150 meters (500 ft.) 

3.

 

Installation Instructions 

The guide contains instructions for:  

 

Mounting the Reader 

 

Wiring the Reader to the Controller 

 

Testing the Reader 

3.1.

 

Mounting the Reader 

1)

 

Determine an appropriate mounting position for 
the Reader.  

2)

 

Peel off the back of the self-stick mounting label 
template included with the unit, and place at the 
desired mounting position. 

3)

 

Using the template as a guide, drill two holes (hole 
size is indicated on the mounting template) for 
mounting the Reader to the surface. Drill a 10 mm 
(7/16") hole for the cable. If mounting on metal, 
place a grommet around the edge of the hole. 

4)

 

Remove the case screw, and slide the rear case 
away from the front case (see Figure 1). 

5)

 

Drill holes into the back of the rear metal case 
according to how you want to mount the Reader 
(see Figure 1). 

6)

 

Attach the Reader to the Controller. 

7)

 

Screw the Reader rear case to its mounting 
location, and return the front case onto the 
mounted rear case. 

8)

 

Secure the front cover by using the supplied 
security screw in the controller accessories kit. Use 
the provided L-shaped tool to tighten the screw. 

Note: Use card readers with a Listed access control unit 
whose power supply is UL Listed Class 2 or equivalent. 

 

Figure 1: 

US Gang Box 

3.2.

 

Wiring the Reader to the Controller 

The Prox Reader is supplied with an 18-inch pigtail, having 
a 6-conductor cable.  

1)

 

Prepare the Reader cable by cutting the cable 
jacket back 11/4 inches, and strip the wires 1/2 
inch. 

2)

 

Prepare the Controller cable by cutting the cable 
jacket back 11/4 inches, and strip the wires 1/2 
inch. 

3)

 

Splice the Reader pigtail wires to the 
corresponding Controller wires and cover each 
connection (see Figure 2). 

4)

 

If the tamper output is being utilized, connect the 
purple wire to the correct input on the Controller.  

5)

 

Trim and cover all conductors that are not used. 