background image

PS-C25TB 

 

Power Managment Enclosure with built in Secure Relay I/O Module 

Installation Manual 

 

1.

 

Introduction 

The PS-C25TB is a Power Management Enclosure for use with 
Rosslare's Secure Stand-Alone Controller Unit. It is a combination of 
the ME-0515M Multipurpose Power Management Enclosure and the 
MD-25TB Secure Relay I/O Module preassembled for installation 
convenience. The secure relay provides power to the Controller Unit. 
The Controller Unit communicates with the secure module through a 
Rosslare proprietary protocol, providing instructions to activate the 
lock/auxiliary relays and a built-in sounder (with bell and siren 
tones). The secure module also communicates the REX input status 
to the Controller Unit. A red LED indicates the secure module power 
status. The secure module includes removable terminal blocks for 
ease of wiring and installation. 
The enclosure features a switch-mode power supply (SMPS) that 
outputs power to the PM-05 power management module. 
The PM-05 power management module has two independent power 
channels with an isolated PTC (self-resetting fuse). One channel 
powers the MD-25TB while the other channel may be used to power 
a lock. Battery backup is available. When AC power fails, the PM-05 

instantaneously (UPS) switches power over to a stand-by sealed 
lead acid (SLA) battery (not included) charged by a built-in battery 
charger. 

Figure 1: PS-C25TB 

 

 

 

 
 

2.

 

Technical Specifications 

2.1

 

Electrical Characteristics 

 SMPS 

Input 

110 

 240 VAC, 50/60 Hz, 1.5 A 

Output 

15 VDC, 4 A 

PM-05 

Input 

15 VDC, 4 A 

DC Output 

14.5 VDC, 2 A (CH1/CH2) 

Battery Charge 
current 

1.5 A 

MD-25TB 

Input 

12 VDC, 2 A 

Output 

12 VDC, 0.25 A (PCB maximum output 
current) 
5 A Form C, SPDT Relay 

Auxiliary Output 

Max Switched Current: 5 A 
Max Switched Voltage: 150 VDC or 300 VAC 
UL Rating: 5 A at 30 VDC or 5 A at 125 VAC 

Speaker Output 

0.25 W, 8 

Ω

 (minimum) 

LED indicators 

Power status: 

 

Red 

 power on 

 

Off 

 power off 

2.2

 

Environmental Characteristics 

Operating Environment 

Indoor 

Operating Temperature Range 

-10°C - 50°C (14°F - 122°F) 

Operating Humidity Range 

0% - 85% (non-condensing) 

2.3

 

Physical Characteristics 

Dimensions  
(H x W x D) 

228 x 224 x 84 mm 

Weight 

2.21 kg (4.87 lb) 

 

3.

 

Installation 

3.1

 

Mounting 

Make sure the mounting location is a flat surface. 

To mount the ME-0515M: 

1.

 

Drill holes in the wall using the enclosure back cover holes as a 
guide (Figure 2)

2.

 

Insert masonry anchors into the drilled holes. 

3.

 

Mount the enclosure on the wall. 

4.

 

Once the PC-C25TB is mounted, it can house a controller and an 
expansion. 

Figure 2. Enclosure Drill Holes 

 