Instruction Manual 
S1 & S2 & S3  
Digital Multimeter 

 

rspro.com

 

Summary of Contents for 199-3847

Page 1: ...EN Instruction Manual S1 S2 S3 Digital Multimeter rspro com ...

Page 2: ...o electric shock and injury replace the battery as soon as low battery indicator blinks Avoid working alone so assistance can be rendered Do not use the Tester if the Tester is not operating properly or if it is wet Individual protective device must be used if hazardous live parts in the installation where the measurement is to be carried out could be accessible Disconnect the test leads from the ...

Page 3: ...r IV according to IEC 61010 031 and shall have a voltage RATING of at least the voltage of the circuit to be measured Only replace the blown fuse with the proper rating as specified in this manual Do not attempt a current measurement when the open voltage is above the fuse protection rating Suspected open voltage can be checked with voltage function Never attempt a voltage measurement with the tes...

Page 4: ...of cardiac pacemakers and implanted defibrillators As a user of such medical devices keep a sufficient distance to the magnet Symbols as marked on the Meter and Instruction manual Unsafe Voltage To alert you to the presence of a potentially hazardous voltage when the Tester detects a voltage 30 V or a voltage overload OL in V mV AutoV PV The symbol is displayed Maintenance Do not attempt to repair...

Page 5: ...unt digital display 3 Push buttons 4 Rotary switch for turn the Power On Off and select the function 5 Input Terminal for Multi function 6 Common Ground reference Input Terminal 7 Input Terminal for A A COM Volt Seek V Volt Seek Light LCD Display Button Rotary Switch V Ω C Input or Common Input A Input ...

Page 6: ...3 EN 5 Features Function S1 S2 S3 ACV DCV DC mV Frequency Resistor Continuity Diode Capacitor Bluetooth Volt Seek AutoV LoZ Data Logger HFR Backlight Bar Graph ACA DCA Temperature AC µA mA DC µA mA PV Voltage ...

Page 7: ...t leads when removing the test leads remove the live test leads before removing the common test leads Measuring Voltage Preparation and Caution Before Measurement Observe the rules of Warnings and Cautions Dial the switch to select the measuring function CAUTION Do not use the LoZ mode to measure voltages in circuits that could be damaged by this mode s low impedance ...

Page 8: ...o select the measuring function CAUTION This function is only available with the dedicated PV test probe Always select correct DC AC mode to perform high voltage measurement This meter will flash symbol and the correct mode symbol AC DC if the input voltage is different and dangerous ...

Page 9: ...S1 S2 S3 EN 8 Measuring Current Dial the switch and press the Function button to select the measuring function Disconnect ...

Page 10: ...ing Capacitance Diode Dial the switch and press the Function button to select the measuring function Measuring Continuity Resistance Dial the switch and press the Function button to select the measuring function Red Black ...

Page 11: ... to select the measuring function C F Volt Seek Dial the switch to select the measuring function Warning The Volt Seek LED indicates the electric field If the Volt Seek LED is not on voltage could still be present Volt Seek Do not hold across this line when sensing the hazardous voltage ...

Page 12: ...unction Press the Function button to change the function on the same switch position Range Button Press Range Button 2 Sec to Enter Auto Range Mode 3 Auto Range Mode 1 Manual Range Mode 2 1 Switch range Switch Position Function ...

Page 13: ... recorded max value the meter records the new value Press Hold button to pause the recording Smart Hold The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts However it can not detect across the AC and DC Voltage Current Press Button 2 sec to exit the MIXMAX mode ...

Page 14: ...Relative button to enable disenable this function Backlight Press the HOLD button over 2 sec to turn on off Backlight Auto Power Off Wakeup the meter by dialing the switch or pressing any button After Specified Time Without Operation HOLD ...

Page 15: ... be 5 minutes 10 minutes 20 minutes and disabled OFF High Frequency Rejection HFR The High Frequency Rejection mode equip a low pass filter in the AC measurements The cut off frequency 3dB point of low pass filter is 800Hz Warning The hazardous voltage may be present even if the LCD reading is very low in HFR mode Verify the voltage again without HFR mode ...

Page 16: ...Testing LCD Monitor To turn on the meter after keeping HOLD button down Function of LOG Button 1 2 3 Pressing Bluetooth button while powering up to select the mode Data Logger mode Manual Saving mode and Clear memory ...

Page 17: ...Time interval setting mode Press Bluetooth button again to select time interval The interval can be 1 second 5 seconds 10 seconds 30 seconds 60 seconds Start to record auto matically after 2 sec without operaction LOG icon flashes while logging Time interval setting mode Caution All stored data will be cleared next startup Download the stored data by App first if needed ...

Page 18: ...wireless technology to transfer the real time reading and the stored data The open air communication range is up to 10m Download RS Pro Connect App Turn on Bluetooth function of the meter and open RS Pro Connect to connect the DMM The Bluetooth icon of the meter will freeze on LCD after the connection establishes successfully Flash To save a reading Show stored reading amount for 2 seconds ...

Page 19: ...S1 S2 S3 EN 18 Default Temperature Units Setting Turn on the meter after keeping Bluetooth button down OR Fuse Replacement ...

Page 20: ... Replacement Replace the battery as soon as the low battery indicator appears to avoid false reading Refer to the following figure to replace the batteries CAUTION Remove test leads from Meter before opening the battery cover or Meter case ...

Page 21: ...ower Requirement AA 1 5V x 2 batteries Operating Temperature 10 10 C 10 C 30 C 80 RH 30 C 40 C 75 RH 40 C 50 C 45 RH Storage Temperature 20 C to 60 C 0 to 80 R H batteries not fitted Altitude 6561 7 ft 2000m CAT Application field Ⅱ The circuits directly connected to Low voltage installation Ⅲ The building installation Ⅳ The source of the Low voltage installation Drop Protection 4 feet drop to hard...

Page 22: ...non sinusoidal waveforms Additional Accuracy by Crest Factor C F Add 3 0 for C F 1 0 2 0 Add 5 0 for C F 2 0 2 5 Add 7 0 for C F 2 5 3 0 Max Crest Factor of Input Signal 3 0 3000 counts 2 0 4500 counts 1 5 6000 counts Frequency Response is specified for sine waveform LCD displays 0 counts when the reading 20 counts 3 DC mV Range OL Reading Resolution Accuracy 600 0mV 660 0mV 0 1mV 0 5 5D Input Imp...

Page 23: ...nge OL Reading Resolution Accuracy 600 0V 660 0V 0 1V 2 0 3D 1000V 1100V 1V Input Impedance less than 3kΩ Frequency Response 45 500Hz Sine Wave Overload Protection AC DC 1000V 7 PV DC Voltage Range OL Reading Resolution Accuracy 600 0V 660 0V 0 1V 2 0 5D 2000V 2200V 1V Input Impedance 10MΩ Overload Protection AC DC 1000V 8 PV AC Voltage Range OL Reading Resolution Accuracy 600 0V 660 0V 0 1V 2 0 5...

Page 24: ...mA 1 5 3D 60 00mA 66 00mA 0 01mA 400 0mA 440 0mA 0 1mA Frequency Response 45 500Hz Sine Wave Overload Protection Fuse AC DC 440mA 11 DC Current Range OL Reading Resolution Accuracy 6 000A 6 600A 0 001A 1 0 3D 10 00A 20 00A 0 01A Maximum measurement time 5A for max 3 minutes with at least 20 minutes rest time 10A for max 30 seconds with at least 10 minutes rest time Overload Protection Fuse AC DC 1...

Page 25: ... 44 00MΩ 0 01MΩ 1 5 5D There is a little rolling less than 50 digits when measuring 10 00 MΩ Overload Protection AC DC 1000V 14 Continuity Range OL Reading Resolution Accuracy 600 0Ω 660 0Ω 0 1Ω 0 9 5D Continuity Built in buzzer sounds when measured resistance is less than 20Ω and sounds off when measured resistance is more than 200Ω Between 20Ω to 200Ω the buzzer maybe sound or off either Continu...

Page 26: ...10 000kHz 10 000kHz 0 001kHz 100 00kHz 100 00kHz 0 01kHz Minimum Sensitivity Ampere 0 6A 18 VoltSeek Voltage Range of High Sensitivity 80V 1000V At the top edge of the meter Voltage Range of Low Sensitivity 160V 1000V At the top edge of the meter 19 HFR High Frequency Rejection Available for AC only Add 4 to specified accuracy of each function and each range for 45Hz to 200Hz Accuracy is unspecifi...

Page 27: ...ccuracy is available with backlight off The heat of backlight may deviate the measurement The accuracy does not include the accuracy of the thermocouple probe Accuracy specification assumes surrounding temperature stable to 1 C For surrounding temperature changes of 2 C rated accuracy applies after 2 hours Overload Protection AC DC 1000V ...

Page 28: ...pair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above RS Components shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or econo...

Page 29: ...No 618 Yan an Eastern Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com U S A Allied Electronics 7151 Jack Newell Blvd S Fort Worth Texas 76118 U S A www allie...