Rumble Tuff 

Electric Breast Pump

Instructions & Assembly

Easy Express

C1說明書-(75-PA20000-RT01)-20130104-A.indd   1

2013/3/4   下午 03:38:52

Summary of Contents for Easy Express

Page 1: ...Rumble Tuff Electric Breast Pump Instructions Assembly Easy Express C1說明書 75 PA20000 RT01 20130104 A indd 1 2013 3 4 下午 03 38 52 ...

Page 2: ...C1說明書 75 PA20000 RT01 20130104 A indd 2 2013 3 4 下午 03 38 52 ...

Page 3: ...g for example to express unsuitable milk while you are undergoing medical treatment The Rumble Tuff Electric Breast Pump provides many of the features busy moms love 4 speed modes and 7 levels of suction Milk back flow protection Quiet motor for discretion Small and lightweight 2 power options to fit your needs AC DC Adapter 4 AA Alkaline batteries not included Indication for Use The Rumble Tuff E...

Page 4: ...n Combo Kit Power Options Using your AC DC Adapter included Using 4 AA Alkaline Batteries Batteries not included Install the Batteries AA Alkaline Pumping Instructions Cleaning Instructions Sanitize Prior to First Use Before Each Use General Cleaning Instructions Tubing Cleaning Instructions Breastmilk Storage Guidelines Important Notes Tips Pumping Tips Battery Storage 0 0 3 3 3 3 5 6 7 8 11 12 1...

Page 5: ...ction Breastmilk Buildup in the Breastshield Body Where to get Replacement Parts Where to get Additional Accessories What Additional Accessories are Available Technical Data Power Requirements Warranty 26 27 27 27 27 28 28 28 28 29 29 30 English 2 C1說明書 75 PA20000 RT01 20130104 A indd 5 2013 3 4 下午 03 38 52 ...

Page 6: ...he product to avoid damage Do not touch the product with bare hands right after sterilizing by boiling water to avoid scalds and burns Do not over boil to avoid premature aging of the product materials WARNING To reduce the risk of burns electrocution fire or injury to persons This product should never be left unattended when plugged in Close supervision is necessary when this product is used near...

Page 7: ...DC Adapter or Li Ion battery pack not approved by the manufacturer voids the warranty If you are infected with Hepatitis A Hepatitis B or have HIV Human Immunodeficiency Virus pumping breast milk does not reduce or remove the risk of transmitting the virus to your baby through breast milk Wash the Expression Collection Combo Kit parts before each use Do not operate a motor vehicle while using the ...

Page 8: ...Parts Guide Breast Pump Main Unit AC DC Adapter Expression Collection Combo Kit Vacuum Tubing with Adapter Bottle Adapter Kit English 5 C1說明書 75 PA20000 RT01 20130104 A indd 8 2013 3 4 下午 03 38 52 ...

Page 9: ...ts Guide Vacuum Adjusting Wheel Expression Button Battery Cover Tubing Adapter Inlet AC DC Adapter Inlet TOP VIEW BOTTOM VIEW T1 T2 T3 T4 LED Screen English 6 Power Button C1說明書 75 PA20000 RT01 20130104 A indd 9 2013 3 4 下午 03 38 52 ...

Page 10: ... Guide Cap Diaphragm Cup with O Ring Breastshield Body One Way Valve Bottle Adapter Collection Bottle Bottle Base Electric pump Diaphragm Kit Expression Collection Kit English 7 C1說明書 75 PA20000 RT01 20130104 A indd 10 2013 3 4 下午 03 38 52 ...

Page 11: ...ield Body in one hand Make sure the bottle thread side opening is facing up 2 With the thumb and forefinger of the other hand hold the tip of the One Way Valve and place the flat circular bottom into the opening Be sure not to stretch bend or twist the tip of the One Way Valve Seal all the edges firmly Note The One Way Valve tip does not have to align with anything as long as all the edges are sec...

Page 12: ...t line Note This is critical to the performance of the Pump 4 Carefully twist on the Bottle Adapter to the Breastshield Body for a secure fit Note Be sure not to bump the One Way Valve when twisting the Breastshield Body the Bottle Adapter pieces together If you bump the One Way Valve repeat step 3 English 9 C1說明書 75 PA20000 RT01 20130104 A indd 12 2013 3 4 下午 03 38 53 ...

Page 13: ... Assemble the Expression Collection Kit Continued 5 With the Bottle Adapter in one hand twist on the Collection Bottle for a secure fit English 10 C1說明書 75 PA20000 RT01 20130104 A indd 13 2013 3 4 下午 03 38 54 ...

Page 14: ...ess around the edges of the Diaphragm for a secure fit Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them 2 Place the Cap on the Cup Diaphragm Be sure to align the hinge and hinge cover Press tightly to seal Hinge cover Hinge English 11 C1說明書 75 PA20000 RT01 20130104 A indd 14 2013 3 4 下午 03 38 55 ...

Page 15: ...til it locks into place 2 Take the open end of Vacuum Tubing the end without the adapter and connect to the Tubing Connector located on the Cap Push together firmly for a tight seal Note Make sure there is no moisture in the Tubing How to Assemble the Expression Collection Combo Kit Turn Clockwise English 12 Tubing Connector C1說明書 75 PA20000 RT01 20130104 A indd 15 2013 3 4 下午 03 38 59 ...

Page 16: ...ession Collection Combo Kit Continued 3 Make sure the Tubing Connector is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit English 13 C1說明書 75 PA20000 RT01 20130104 A indd 16 2013 3 4 下午 03 39 00 ...

Page 17: ... be operated under any of the following power supply modes Using your AC DC Adapter included Electrical safety can only be achieved when using the AC DC Adapter which was provided with the Pump Use of any another Adapters causes concern for the safety of the product and or the user and voids the warranty English 14 C1說明書 75 PA20000 RT01 20130104 A indd 17 2013 3 4 下午 03 39 00 ...

Page 18: ...mental protection and recycling Note Alkaline Batteries may present a risk of fire or chemical burn if mistreated Do NOT disassemble any battery Do NOT place batteries near heat source or fire Dispose of used batteries properly Do NOT dispose of batteries in fire Keep away from children AA Battery Compartment 4 AA Batteries not included Using 4 AA Alkaline Batteries not included English 15 C1說明書 7...

Page 19: ...1 Open the Battery Cover 2 Remove the old batteries if you are replacing them Install the Batteries AA Alkaline English 16 C1說明書 75 PA20000 RT01 20130104 A indd 19 2013 3 4 下午 03 39 01 ...

Page 20: ...ne Continued 3 Insert 4 new AA Alkaline Batteries Note Make sure the polarity is correct as indicated 4 Close the Battery Cover making sure it snaps into place English 17 C1說明書 75 PA20000 RT01 20130104 A indd 20 2013 3 4 下午 03 39 02 ...

Page 21: ...ection Kit to your breast so that your nipple is centered inside the Breastshield 2 Press the Power Button to begin pumping English 18 Note Please check for correct fitting of the shield C1說明書 75 PA20000 RT01 20130104 A indd 21 2013 3 4 下午 03 39 02 ...

Page 22: ... different pumping speed just press the Expression Button to switch between 4 different speed modes Suction speed gradually slows down from T1 to T4 Note The Expression suction speed is switched in following sequence T1 T2 T3 T4 T3 T2 T1 English 19 C1說明書 75 PA20000 RT01 20130104 A indd 22 2013 3 4 下午 03 39 03 ...

Page 23: ...ressing the Power Button Note Make sure there is no suction on the nipples before removing the Breastshield If necessary break the suction by inserting a finger between the Breastshield and the breasts similar to the way you break away from your baby s suction Pumping Instructions Continued Note If the Rumble Tuff Electric Breast Pump is left on but unattended for more than 30 minutes the Pump wil...

Page 24: ...parts or attachments Make sure all parts are clean and dry Ensure the Tubing is free from any liquid Do NOT operate your Rumble Tuff Electric Breast Pump if any liquid is visible in the Tubing See Tubing Cleaning Instructions on page 22 General Cleaning Instructions Set aside the Tubing and Tubing Connector Under the normal working conditions of the pump the diaphragm prevents the back flow of mil...

Page 25: ...de the Tubing If liquids are found inside Tubing rinse the Tubing with clean hot water Hang to AIR DRY COMPLETELY BEFORE USING Do NOT insert any object into the Tubing Note Before each use visually inspect the individual components for cracks chips tears discoloration or deterioration as they may affect the efficiency of the Rumble Tuff Electric Breast Pump In the event that damage to the device i...

Page 26: ... the inside of your wrist before feeding it to your baby The milk should feel warm not hot WHAT TO DO Storing milk in 2 to 4 oz amounts may reduce waste Write the date you expressed your milk on the container include your baby s name on the label if your baby is in a daycare setting Use the oldest milk first Throw away previously frozen milk that is not used within 24 hours WHAT NOT TO DO Do NOT h...

Page 27: ... high Smaller cooler with a blue ice pack 59 F 24 hours Keep ice packs in contact with milk containers at all times limit opening cooler Countertop table Room temp 60 F 85 F Up to 3 4 hours is best Up to 6 8 hours is okay for very clean expressed milk Containers should be covered and kept as cool as possible covering the container with a clean cool towel may keep milk cooler Throw out any leftover...

Page 28: ...nd don t even notice the change To achieve multiple let downs which mimics the natural reflex found in breast feeding you can switch the suction speeds T1 fastest and T4 slowest just by pressing the Expression Button The suction speed is switched in the following sequence T1 T2 T3 T4 T3 T2 T1 Remember that successful pumping is a learned skill Don t get discouraged and keep working at it to obtain...

Page 29: ...re within the following temperature range 32 F to 77 F 0 C to 25 C Breastfeeding Tips The Rumble Tuff Electric Breast Pump helps you maintain a supply of milk and can help you prepare for planned events such as Date Night or unexpected events such as power outages medical treatment or relief from tender nipples Tips Continued English 26 C1說明書 75 PA20000 RT01 20130104 A indd 29 2013 3 4 下午 03 39 04...

Page 30: ...different circuit from that which the other device s are connected Consult the manufacturer or a field service technician of the device receiving interference for help There is no guarantee that interference will not occur Decreased Suction If it feels like the suction has decreased try the following Make sure the Expression Collection Combo Kit is assembled correctly see pages 8 13 Inspect the On...

Page 31: ...ment parts or additional accessories for your Rumble Tuff Electric Breast Pump by the following methods Email sales rumbletuff com Fax 801 796 2688 Toll Free 855 228 8388 Additional Accessories Troubleshooting Continued English 28 Parts Breastshield Body and Bottle Adapter wide Bottle Set 2 sets Vacuum Tube with adapter for Single Pump DC 12V Power Adapter UL One Way Valve Diaphragm Kit Bottle Set...

Page 32: ... 1 5V Alkaline Technical Specifications VACUUM T1 phase 177mmHg 23 6kpa T2 phase 216mmHg 28 9kpa T3 phase 240mmHg 32kpa T4 phase 250mmHg 33 4kpa Ambient temperature range 10O C to 40O C 50O F to 104O F Relative Humidity range 20 to 80 Key to Box Symbol Type BF equipment Breastshield Consult instructions for use Disposal of Electrical Electronic Equipment WEEE English 29 C1說明書 75 PA20000 RT01 20130...

Page 33: ...LIMITED IN DURATION TO A PERIOD OF 120 DAYS FROM THE DATE OF PURCHASE BY THE ORIGINAL PURCHASER In the event that this product if found by Rumble Tuff to not meet the above limited warranty as purchaser s sole and exclusive remedy Rumble Tuff will repair or at the option of Rumble Tuff replace this product without charge for such replacement parts or labor The purchaser shall bear all expenses rel...

Page 34: ... You the purchaser are responsible for all shipping charges To obtain an RA and shipping address Please contact Rumble Tuff Customer Service Department by Toll free 855 228 8388 or E mail to customerservice rumbletuff com or In writing to Customer Service Department Rumble Tuff 865 N 1430 W Orem UT 84057 Items returned without a RA will not be processed and will be returned to sender postage due C...

Page 35: ...wned and operated by A Cute Baby Inc 865 N 1430 W Orem UT 84057 6402 Tel 801 609 8168 Fax 801 796 2688 www rumbletuff com www acutebaby com 75 PA200S0 RT01 C1說明書 75 PA20000 RT01 20130104 A indd 35 2013 3 4 下午 03 39 04 ...