background image

- 1 -

SAINLOGIC SC089

Professional WiFi Weather

Station User Manual

1. Introduction..........................................................................3

2. Warnings and Cautions........................................................3

3. Getting Started.....................................................................3

3.1 Parts List.........................................................................3

3.2 Recommend Tools.........................................................6

3.3 Sensor Assembly Set Up................................................6

3.3.1 Install Integrated Outdoor Sensor Battery

..

..............6

3.4 Display Console..............................................................9

3.4.1 Layout of Display Console.......................................9

3.4.2 Setup the Display Console ......................................9

3.4.3 Connect Sensors with Display Console.................11

3.5 Sensor Operation Verification.......................................11

3.6 WiFi Setup Guide.........................................................12

4. Sensors Pre-Installation.....................................................12

4.1 Test the Sensors Before Installation.............................12

4.2 Site Survey Before Installation......................................13

4.3 Best Practices for Wireless Communication.................14

5. Final Installation of Sensors...............................................15

5.1 Integrated outdoor Sensor Installation..........................15

6. Low Battery Icon................................................................20

7. Display Console Operation................................................20

7.1 Quick Display Mode......................................................20

7.2 Set (Program) Mode....................................................21

7.3 Sensor Search Mode................................................24

7.4 Max/Min Viewing and Reset Mode...............................24

7.5 Snooze Mode...............................................................26

Summary of Contents for SC089

Page 1: ...3 4 3 Connect Sensors with Display Console 11 3 5 Sensor Operation Verification 11 3 6 WiFi Setup Guide 12 4 Sensors Pre Installation 12 4 1 Test the Sensors Before Installation 12 4 2 Site Survey Bef...

Page 2: ...30 9 1 Calibration of Temperature Mode 31 9 2 Calibration of Humidity Mode 32 9 3 Calibration of Sensors Mode 32 10 Other Features of Display Console 37 10 1 Weather Forecasting 37 10 2 Weather Icons...

Page 3: ...g pole Never install the weather station in a storm Warning Installing your weather station in a high location may result in injury or death Perform as much of the initial check out and operation on t...

Page 4: ...6 7x3 1inch 171x78mm 1 Integrated Outdoor Transmitter Dimensions 13x11x5 9 inch 330x280x150mm 1 Foot Mounting with pole insert Dimensions 4x3x1 5inch 101x76x37mm 1 Mounting Bracket Back Plate pole mo...

Page 5: ...5 QTY Item Image 2 Pole mounting nuts M3 bolts 3 4 Pole mounting nuts M5 bolts 5 4 Tapping screws 1 Manual 1 Power Adapter Figure 1...

Page 6: ...y must be powered and updating before powering up the console or the console will stop scanning and connecting with the sensors The following illustration shows the full segment of integrated outdoor...

Page 7: ...can permanently damage the outdoor sensors The solar panel does not charge the batteries so rechargeable batteries are not recommended Figure 3 Remove the battery door on the back of the sensor by re...

Page 8: ...et screw Note We recommend installing Lithium AA batteries for outdoor sensors in cold weather environments The Integrated outdoor sensor LED indicator White button will light for 3 seconds and then f...

Page 9: ...Display Console The following illustration shows display console features in normal mode as below 3 4 2 Setup the Display Console 1 Plug in the display console with power adapter BL ON will display in...

Page 10: ...shown in Figure 7 Install three AAA alkaline or lithium batteries The display will beep once and layout of display will light up for a few seconds to verify all segments are operating properly Figure...

Page 11: ...onnected with the Integrated Outdoor Sensor the measured value Outdoor temperature humidity wind speed wind direction wind gust and average rainfall UV and Sunlight index Dew point and feels like will...

Page 12: ...s to stabilize 4 Verify proper operation of in outdoor humidity Verify the indoor and outdoor humidity Verify the indoor and outdoor humidity match closely with the console and sensor array in the sam...

Page 13: ...thumb is to install the sensor array at least four times the distance of the height of the tallest obstruction For example if the building is 20ft 6m tall install 4 x 20 6 56ft 17m away Use common se...

Page 14: ...relocate the wireless transmitters or receivers to avoid intermittent communication 3 Line of Sight Rating This device is rated at 300ft line of sight no interference barriers or walls but typically...

Page 15: ...tion This Professional Weather Station can be used in both the Northern and Southern Hemispheres Prior to installation you will need to calibrate the wind direction Note There are four alphabet letter...

Page 16: ...f South Step 2 Console operation set to Northern Hemispheres NOR in the time area in Location division Check the detailed step of setting the time area in the part 17 of Chapter 7 2 5 1 2 Southern Hem...

Page 17: ...match with your real location If the wind direction sensor is not positioned correctly during installation permanent wind direction error will be introduced 5 1 3 Mounting Fixing the Sensor Horizontal...

Page 18: ...18 Figure 10 F...

Page 19: ...door sensor to the mounting pole brackets with two foot mounting screws 3 bolts and M3 nuts Then tighten the mounting pole to your existing mounting pole with the four bolts 5 and nuts M5 or fix it on...

Page 20: ...ever mix battery types such as alkaline and lithium together 7 Display Console Operation 7 1 Quick Display Mode Note The display console has five keys for easy operation MAX MIN key ALARM key SET key...

Page 21: ...key to toggle between absolute pressure and relative pressure 4 Outdoor Temperature Press the CHANNEL or MAX MIN key to toggle between outdoor temp dew point and feels like 7 2 Set Program Mode While...

Page 22: ...again to enter the Day Month format mode Press the CHANNEL or MAX MIN key to switch between M D D M 5 Change Month Press the SET key again to set the calendar month Press the CHANNEL key or MAX MIN ke...

Page 23: ...light Display Units default W Press the SET key again to change the sunlight units of measure Press the CHANNEL key or MAX MIN key to toggle the sunlight units between W fc or lux 13 Barometric Pressu...

Page 24: ...sition of the earth Northern Hemisphere NOR or Southern Hemisphere NOR Refer to 5 0 Final Installation of Sensors 7 3 Sensor Search Mode If Integrated Outdoor Transmitter data is lost touch and hold t...

Page 25: ...values will display the current values after reset 7 5 2 Min Record Viewing and Reset Press the MAX MIN key again do not hold the MIN icon will be displayed Press the SET key to view min values of pr...

Page 26: ...SNOOZE key to switch between the 3 levels In the brightest backlight of 3 levels press the SNOOZE key to turn off the backlight When backlight is off with adapter press the SNOOZE key and the backlig...

Page 27: ...t the same time Alarm 1 time and HI alarm parameters of indoor temperature and humidity outdoor temperature and humidity 1h rainfall wind gust wind average absolute pressure UV index Sunlight are disp...

Page 28: ...l begin flashing alarm hour To save the alarm setting and proceed to the next alarm parameter Press do not hold the SET key To adjust the alarm parameter press the CHANNEL key or MAX MIN key to increa...

Page 29: ...the humidity falls below 56 at which point the alarm will reset and must increase above 60 to activate again 1 Alarm hour alarm 1 2 Alarm minute alarm 1 3 Alarm hour alarm 2 4 Alarm minute alarm 2 5 W...

Page 30: ...ed humidity range is between 10 and 99 Humidity cannot be accurately measured outside of this range Thus the humidity cannot be calibrated below 10 or above 99 The purpose of calibration is to fine tu...

Page 31: ...nter the temp calibration mode The indoor temperature will begin flashing Press the CHANNEL key or MAX MIN key to increase or decrease the temperature reading in increments of 0 1 Press and hold the C...

Page 32: ...To exit the humidity calibration mode at any time press the SNOOZE LIGHT or SET button on the top of the display console If no operation is performed the calibration mode will timeout in 30 seconds N...

Page 33: ...increase or decrease rapidly Press the ALARM key to reset current value Example The calibrated pressure sources measure 28 37 inHg The display console pressure reads 28 75 inHg Offset 28 37 28 75 0 38...

Page 34: ...your location would be at if located at sea level is generally higher than your measured pressure Thus your absolute pressure may read 28 62 inHg 969 mb at an altitude of 1000 feet 305 m but the rela...

Page 35: ...d hold the CHANNEL or MAX MIN key for three seconds to increase or decrease rapidly Press the ALARM key to reset current value Note The wind gust is also affected by the wind speed calibration factor...

Page 36: ...MIN key to adjust the rain calibration factor from 0 75 to 1 25 where Calibrated Rain Calibration factor x Measured Rain Press and hold the CHANNEL or MAX MIN key for three seconds to increase or decr...

Page 37: ...to increase or decrease rapidly Press the ALARM key to reset current value To exit the Sensor calibration mode at any time press the SNOOZE LIGHT button on the display console If no operation is perfo...

Page 38: ...be relied upon as an accurate method to predict the weather 10 2 Weather Icons Condition Icon Description Sunny Pressure is rising and the previous condition is partly cloudy Partly Cloudy Pressure is...

Page 39: ...following moon phases are displayed based on the calendar date 10 4 Feels Like Temperature Feels like temperature is a combination of Heat Index and Wind Chill 1 Temperatures less than 4 4 C 40 F the...

Page 40: ...40 2 Temperatures greater than 26 7 C 80 F the heat index is displayed as shown in the National Weather Service Heat Index Table below...

Page 41: ...ns where the air pressure is typically stagnant 10 6 Restore Factory Default To reset the display console to factory default WiFi network Weather server and display press the MAX MIN key while pluggin...

Page 42: ...42 A Remove the rain collector funnel...

Page 43: ...onsole There are dashes on the display console If any of the sensor communication is lost dashes will be displayed on the screen To reacquire the signal press and hold the CHANNEL button for 3 seconds...

Page 44: ...t under most conditions Move the sensor assembly closer to the display console If the sensor assembly is too close less than 1 5m 5ft move the sensor assembly away from the display console Install a f...

Page 45: ...o not agree Allow up to one hour for the sensors to stabilize due to signal filtering The indoor and outdoor temperature sensors should agree within 2 C 4 F the sensor accuracy is 1 C 2 F Use the cali...

Page 46: ...13 Specification 13 1 Measurement Specifications The following table provides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 0 to 60 C 32 to 140 F...

Page 47: ...date Period 16s UV Index 1 to 15 1 1 Sunlight 0 to 200klux 15 15 Rain 0 to 9999mm 15mm 1 mm 15mm to 9999mm 7 1000mm 0 3mm 1000mm 1mm Wind Direction 0 360 10 16 point compass 1 16 point compass Wind Sp...

Page 48: ...re is limited solar energy Note Solar panel doesn t charge the battery and it is an auxiliary power supply Adapter 5 9V 500mA included Battery life Minimum 12 months for sensors use lithium batteries...

Reviews: