background image

Pump installation and warranty 

guide for the CT range of pumps

CT FORCE

15 PT, 15 TU, 15 IPT, 15 ITU
20 PT, 20 TU, 20 IPT, 20 ITU
20 PS, 20 SU, 20 IPS, 20 ISU
30 PT, 30 TU, 30 IPT, 30 ITU
30 PS, 30 SU, 30 IPS, 30 ISU

CT Xtra

50, 50+, 54
55, 55+, 59
64H, 64HU, 69H, 69HU
75, 75+, 79, 84H, 84HU
85, 85+, 89, 94H, 94HU

CT Bathroom

60B, 60BU, 80B, 80BU, 90BU

Quality | Technology | Service | Value

Models shown:

CT FORCE 15PT

CT 50 Xtra

CT 60BU Bathroom

IS

SU

D

N

O

V

 2

01

4

x140812_SP_p6_nm_x140812_SP_p6_nm  28/10/2014  11:29  Page 1

Summary of Contents for CT Series

Page 1: ...PS 20 ISU 30 PT 30 TU 30 IPT 30 ITU 30 PS 30 SU 30 IPS 30 ISU CT Xtra 50 50 54 55 55 59 64H 64HU 69H 69HU 75 75 79 84H 84HU 85 85 89 94H 94HU CT Bathroom 60B 60BU 80B 80BU 90BU Quality Technology Serv...

Page 2: ...can give you first rate advice regarding installation Consulting the helpline will entitle your customer to an additional two years warranty FREE UK only for CT FORCE pumps and an additional 1 year w...

Page 3: ...instructions 4 Step 1 Pump location 6 Step 2 Connecting the pump 10 Step 3 Electrical installation 11 PumpWise Guidelines 12 General specifications 17 Technical specifications 19 Trouble shooting 22...

Page 4: ...nlet Multiple cold water storage cisterns must be linked in accordance with current plumbing regulations and the bottom of the cisterns must be at the same level Hot water supply to the pump must be v...

Page 5: ...ion guide Never use mechanical tools to tighten plastic coupler nuts as this may cause damage and invalidate your warranty Never use jointing compounds Boss White Hemp or steel wool Solder fluxes must...

Page 6: ...water capacity is adequate for the entire household requirements eg minimum 136 litres 30 gal for shower only 227 litres 50 gal per bathroom or 364 litres 80 gal for one bathroom plus an en suite show...

Page 7: ...one of the 22mm approved top entry flanges see page 14 22mm No Stop Essex flange with 76mm dip pipe and birds beak cut end to limit air being drawn into the pump Indirect coil Pump inlet Outlet OR ALT...

Page 8: ...dance with BS7671 2008 it should also be noted that BS7671 2008 is a guide In BS7671 2008 rooms containing baths or showers should be broken down into zones These zones are summarised as ZONE 0 This i...

Page 9: ...pump is fitted above cylinder a No Stop Essex flange must be used 14 Check that water storage capacity recovery meets required flow rates particularly at peak demand i e appliances in simultaneous use...

Page 10: ...e the pump automatically even where no natural flow exists UK CT pumps suitable for negative head operation are CT FORCE 15 TU 20 TU 20 SU 30 TU and 30 SU and CT Bathroom 60BU 80BU 90BU Irish CT pumps...

Page 11: ...m Check for leaks DO NOT RUN PUMP DRY to do so will cause irreparable damage to your pump and will invalidate your warranty Open shower mixer valve system outlets to maximum hot and cold to check the...

Page 12: ...st not be used to tighten plastic coupler nuts as this may cause damage which will invalidate the warranty B Hose to pump Do not twist or bend anti vibration hoses as this will invalidate the warranty...

Page 13: ...similarly qualified person in order to avoid a hazard All pipe work must be cross bonded in accordance with the IET Regulations The pump is supplied with a fuse fitted Higher rate fuses MUST NOT be u...

Page 14: ...f a pumped system a water starvation protection unit WSP may be considered See fig 11 The WSP is a Salamander level switch which must be positioned 102mm higher than the highest outlet from the cold w...

Page 15: ...As horizontal Torpedo cylinders are problematic for boosted systems consult PumpWise on 0191 516 2002 for guidance and correct use of an approved top entry flange S flange Complete with compression pu...

Page 16: ...old feed to the cylinder MUST be in 28mm pipework MAX 60 C A B C Usable capacity minimum 50 gallons per bathroom Never less than 1 2m for any top entry flange Warix flange Unpumped outlets Water hamme...

Page 17: ...should not normally exceed 60 C and in a combined central heating and domestic hot water system it is recommended that the stored water temperature is controlled independently from that on the primar...

Page 18: ...the temperature of the stored hot water is uncontrolled see below Usable capacity minimum 50 galls per bathroom Vent and other services Salamander approved HWS TMV Blending valve controller is factor...

Page 19: ...mechanical seal to stick if left for long periods without use The pump must be run at least five minutes every four weeks to exercise all working parts Connections BSP male Initiation Fully automatic...

Page 20: ...al seal to stick if left for long periods without use The pump must be run for at least five minutes every four weeks to exercise all working parts Connections BSP male Initiation Only applies to posi...

Page 21: ...FORCE 20 IPS 2 0 Bar Single End Positive Head Shower Pump 3A 130 1 3 170 1 7 200 2 0 22mm 21mm 4 22 190 120 165 5 27 295 215 205 FORCE 30 PS FORCE 30 IPS 3 0 Bar Single End Positive Head Shower Pump...

Page 22: ...5 4 55 295 215 205 CT 75 Xtra 2 0 Bar Twin End Positive Head Shower Pump 3A 150 1 5 170 1 7 200 2 0 15mm Inlet only 3 78 195 120 165 4 55 295 215 205 CT 79 Xtra 2 0 Bar Twin End Positive Head Shower P...

Page 23: ...80 1 8 21mm 3 38 195 120 165 4 10 295 215 205 CT 94 H Xtra 2 6 Bar Single End House Pump 3A 200 2 0 240 2 4 260 2 6 21mm 5 22 225 120 165 6 06 295 215 205 CT Xtra CT Bathroom House Universal Pumps CT...

Page 24: ...rs are straight and not bent or distorted Air in system Run system on full hot with pump switched off i e gravity only for several minutes Check cold water storage is correct for installation Ensure c...

Page 25: ...helpline 0191 516 2002 PumpWise from Salamander helps customers and provides a support service second to none Installers and customers can be sure of a speedy response to requests for technical help...

Page 26: ...njoying the showering sensation brought to you by your Salamander Pump complete and return the attached Warranty card take care that the temperature of your stored water NEVER exceeds the recommended...

Page 27: ...pe not specified by the Company or if the equipment is incorrectly installed or operated or used other than as described in the instruction manual or if any servicing or repair of the equipment shall...

Page 28: ...nted the warranty periods detailed in points 3 a i and 3 a iii will be extended by 2 years for the CT FORCE pump range to 5 years total UK only and by 1 year for the CT Xtra and CT Bathroom pump range...

Page 29: ...27 Notes x140812_SP_p2_rr_x140812_SP_p2_rr 16 10 2014 13 01 Page 27...

Page 30: ...28 Notes x140812_SP_p2_rr_x140812_SP_p2_rr 16 10 2014 13 01 Page 28...

Page 31: ...Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE x140812_SP_p2_rr_x140812_SP_p2_rr 16 10 2014 13 01 Page 29...

Page 32: ...water cylinder have a flange fitted Yes no Surrey Warix No Stop Essex 1st Tee on downward leg 45 vent 9 What size is the supply pipework to the pump 15mm 22mm How long is the supply pipework to the p...